Skip to content
DraconiticResearch
Search Sources API
277,308 studies31 sourcesUpdated 5 min ago
PreprintCC BY 4.0arXiv

How many events does entanglement-based positronium imaging need? Information limits of Compton polarimetry with CZT detectors

Abstract

The degree of polarisation correlation of the two annihilation photons, measured by Compton polarimetry, has been proposed as a PET biomarker of tissue microstructure, but the statistics it requires have not been quantified. We parameterise the measurement by the linear-polarisation correlation coefficient κ (κ=1 maximally entangled, 1/2 separable), derive the classical Fisher information of double-Compton events and compare it with the quantum Fisher information, relate κ to the annihilation channels of positronium in tissue, and simulate pixelated CdZnTe (CZT) rings. The model is checked against three published measurements and an independent GATE/Geant4 simulation. A double-Compton event carries at most 0.12-0.14 units of Fisher information about κ and 0.015 on average, 0.1-0.6% of the quantum limit. Event-wise maximum likelihood reaches the Cramer-Rao bound, whereas the conventional ratio R needs 1.2-2.3 times more events. The observed coefficient is κobs=1−α(1−κpick), with a pick-off share α of 0.13-0.29 in tissue; it is sensitive to lipid fraction but not to oxygen, and carries no tissue information if pick-off photons are maximally entangled. Published porous-polymer data imply κpick = 0.34-0.58. In a 15-mm CZT module, ordering ambiguity, position errors and electron transport roughly halve the information per event, and sequence reconstruction of multi-site events recovers this loss. With 18F and an eight-module ring, κ can be measured to ±0.01 in a 10-mm tumour, but separating tissues by κ alone requires 6-74 times more decays than are available.

Related

  1. Correlation Harvesting by Unruh--DeWitt Detectors in a Cylindrical Cavity: Entanglement, Mutual Information, and Quantum Discord
    Shagun Kaushal, Harkirat Singh Sahota
    arXivPreprintarXiv licenceFull textQuantum physics & quantum informationarXiv
  2. Three-Photon Bayesian Imaging of Ortho-Positronium
    L. Raczynski, W. Krzemien, A. Coussat +5
    arXivPreprintCC BY 4.0Full textBiological & medical physicsComputational physicsarXiv
  3. High Energy Photon Polarimetry at Lepton Colliders: Quantum Information from Converted Photons
    Carlos Henrique de Lima, Navin McGinnis, David McKeen
    arXivPreprintCC BY 4.0Full textHigh-energy & particle physicsarXiv
  4. A General Master Equation for Two Accelerated Detectors: Stationary States and Entanglement
    Riccardo Acquaviva, Paolo Facchi
    arXivPreprintCC BY 4.0Full textQuantum physics & quantum informationarXiv
  5. A Pipeline for the AI-Assisted Analysis of Imaging X-ray Polarimetry Explorer Observations of Black Hole X-ray Binaries and Limits on Their Polarization Variability
    B. Domine, B. Liu, H. Krawczynski +3
    arXivPreprintCC BY-NC-ND 4.0Full textHigh-energy astrophysicsInstrumentation & methodsarXiv
BibTeX
@misc{zhou2026many,
  title = {{How many events does entanglement-based positronium imaging need? Information limits of Compton polarimetry with CZT detectors}},
  author = {Haitao Zhou and Ruonan Wang and Jianyong Hu and Zhifang Wu and Sijin Li},
  howpublished = {arXiv},
  year = {2026},
  month = nov,
  doi = {10.48550/arxiv.2611.21022},
  eprint = {2611.21022},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2611.21022},
  note = {CC BY 4.0},
}
RIS
TY  - UNPB
TI  - How many events does entanglement-based positronium imaging need? Information limits of Compton polarimetry with CZT detectors
AU  - Haitao Zhou
AU  - Ruonan Wang
AU  - Jianyong Hu
AU  - Zhifang Wu
AU  - Sijin Li
PY  - 2026
DA  - 2026/11/16
PB  - arXiv
DO  - 10.48550/arxiv.2611.21022
UR  - https://arxiv.org/abs/2611.21022
AB  - The degree of polarisation correlation of the two annihilation photons, measured by Compton polarimetry, has been proposed as a PET biomarker of tissue microstructure, but the statistics it requires have not been quantified. We parameterise the measurement by the linear-polarisation correlation coefficient κ (κ=1 maximally entangled, 1/2 separable), derive the classical Fisher information of double-Compton events and compare it with the quantum Fisher information, relate κ to the annihilation channels of positronium in tissue, and simulate pixelated CdZnTe (CZT) rings. The model is checked against three published measurements and an independent GATE/Geant4 simulation. A double-Compton event carries at most 0.12-0.14 units of Fisher information about κ and 0.015 on average, 0.1-0.6% of the quantum limit. Event-wise maximum likelihood reaches the Cramer-Rao bound, whereas the conventional ratio R needs 1.2-2.3 times more events. The observed coefficient is κ_obs=1−α(1−κ_pick), with a pick-off share α of 0.13-0.29 in tissue; it is sensitive to lipid fraction but not to oxygen, and carries no tissue information if pick-off photons are maximally entangled. Published porous-polymer data imply κ_pick = 0.34-0.58. In a 15-mm CZT module, ordering ambiguity, position errors and electron transport roughly halve the information per event, and sequence reconstruction of multi-site events recovers this loss. With ^18F and an eight-module ring, κ can be measured to ±0.01 in a 10-mm tumour, but separating tissues by κ alone requires 6-74 times more decays than are available.
ER  -