Skip to content
DraconiticResearch
Search Sources API
277,308 studies31 sourcesUpdated 13 min ago
PreprintCC BY 4.0arXiv

Three-Photon Bayesian Imaging of Ortho-Positronium

Abstract

PET provides functional images relying on two-photon coincidences from positron-electron annihilation. In human tissue, about 40\% of annihilations are preceded by Ps formation, of which o-Ps component partially decays into three photons, with the remainder annihilating via pick-off or spin-exchange into two photons. This three-photon channel carries additional information about the surrounding micro-environment, including the three-to-two-photon yield ratio as a potential diagnostic marker. We propose the TRIO algorithm, a novel three-photon event-by-event image reconstruction algorithm formulated as a Bayesian maximum a posteriori inference problem. TRIO unifies time-based trilateration, energy-based reconstruction and, for the first time, a physics-informed prior derived from the QED description of Ps decay within a single probabilistic framework. In contrast to positronium lifetime imaging, which requires a prompt photon and is therefore restricted to specific radionuclides, TRIO relies solely on the three photons and is fully compatible with standard radionuclides such as 18F. Monte Carlo simulation modelled after the Siemens Biograph Quadra scanner demonstrates a mean position error of 1.65~cm, improving by a factor of about 2.8 over the time-based trilateration (4.59 cm) and a factor of about 5.3 over energy-based reconstruction alone (8.7 cm). More importantly, the proposed Bayesian approach is compatible with existing TOF-PET scanners that can register three-photon annihilation coincidences.

Related

  1. How many events does entanglement-based positronium imaging need? Information limits of Compton polarimetry with CZT detectors
    Haitao Zhou, Ruonan Wang, Jianyong Hu +2
    arXivPreprintCC BY 4.0Full textQuantum physics & quantum informationarXiv
  2. Sensor-aware physical modelling for deep learning-based single-photon imaging
    Yiwei Chen, Xun Lang, Yu Pan
    Optics ExpressPeer-reviewedPublisher termsApplied physics & instrumentationCrossref
  3. Statistically calibrated effective projected optical-depth imaging from paired photon-counting returns
    Jiyu Xue, Zehua Ning, Yuxin Wu +2
    Optics ExpressPeer-reviewedLicence not statedOptics & photonicsCrossref
  4. Non-line-of-sight imaging using a multimode-fiber-coupled fractal superconducting nanowire single-photon detector
    Song Li, Zuzeng Lin, Xiaolong Hu
    Optics ExpressPeer-reviewedLicence not statedOptics & photonicsCrossref
  5. Three-dimensional photon transport in spinodal photocatalytic aerogels: How bicontinuous morphology controls kinetic rate constants
    Renaud A.L. Vallée
    Next ResearchPeer-reviewedPublisher termsFull text1 citedCatalysisOptics & photonicsHAL
BibTeX
@misc{raczynski2026threephoton,
  title = {{Three-Photon Bayesian Imaging of Ortho-Positronium}},
  author = {L. Raczynski and W. Krzemien and A. Coussat and M. Bala and B. C. Hiesmayr and K. Klimaszewski and M. Obara and R. Y. Shopa},
  howpublished = {arXiv},
  year = {2026},
  month = nov,
  doi = {10.48550/arxiv.2607.27741},
  eprint = {2607.27741},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2607.27741},
  note = {CC BY 4.0},
}
RIS
TY  - UNPB
TI  - Three-Photon Bayesian Imaging of Ortho-Positronium
AU  - L. Raczynski
AU  - W. Krzemien
AU  - A. Coussat
AU  - M. Bala
AU  - B. C. Hiesmayr
AU  - K. Klimaszewski
AU  - M. Obara
AU  - R. Y. Shopa
PY  - 2026
DA  - 2026/11/11
PB  - arXiv
DO  - 10.48550/arxiv.2607.27741
UR  - https://arxiv.org/abs/2607.27741
AB  - PET provides functional images relying on two-photon coincidences from positron-electron annihilation. In human tissue, about 40\% of annihilations are preceded by Ps formation, of which o-Ps component partially decays into three photons, with the remainder annihilating via pick-off or spin-exchange into two photons. This three-photon channel carries additional information about the surrounding micro-environment, including the three-to-two-photon yield ratio as a potential diagnostic marker. We propose the TRIO algorithm, a novel three-photon event-by-event image reconstruction algorithm formulated as a Bayesian maximum a posteriori inference problem. TRIO unifies time-based trilateration, energy-based reconstruction and, for the first time, a physics-informed prior derived from the QED description of Ps decay within a single probabilistic framework. In contrast to positronium lifetime imaging, which requires a prompt photon and is therefore restricted to specific radionuclides, TRIO relies solely on the three photons and is fully compatible with standard radionuclides such as 18F. Monte Carlo simulation modelled after the Siemens Biograph Quadra scanner demonstrates a mean position error of 1.65~cm, improving by a factor of about 2.8 over the time-based trilateration (4.59 cm) and a factor of about 5.3 over energy-based reconstruction alone (8.7 cm). More importantly, the proposed Bayesian approach is compatible with existing TOF-PET scanners that can register three-photon annihilation coincidences.
ER  -