Skip to content
DraconiticResearch
Search Sources API
182,544 studies31 sourcesUpdated 2 min ago
Peer-reviewedCC BY 4.0Scientific Reports

Ex-vivo magnetic resonance elastography detects inflammation-associated biomechanical changes in a mouse model of Salmonella-induced colitis

Abstract

Inflammation alters the mechanical properties of soft tissues, yet the biomechanics of the inflamed intestine remain poorly characterized. Using magnetic resonance elastography (MRE), we characterized colonic biomechanical properties in a murine colitis model. CBA/J mice infected with Salmonella Typhimurium were sacrificed at days 5, 16 and 30 post infection alongside uninfected controls. Ex-vivo tabletop MRE and the Springpot model yielded shear modulus µ (stiffness) and powerlaw exponent α (structure). Collagen, hyaluronic acid and periostin content, immune-cell infiltration, epithelial apoptosis and histopathological scoring were assessed histologically. Colonic stiffness decreased at day 5 (1.7 ± 0.7 kPa) versus controls (5.5 ± 4.0 kPa; p = 0.0002), concurrent with development of edema, immune-cell infiltration and apoptosis, without concomitant ECM changes. Stiffness normalized by day 30 and correlated negatively with the histopathological score ( r = − 0.40, p = 0.002) and the total cell count ( r = -0.47, p = 0.002). At day 5, µ discriminated infected from control colons with an AUC of 0.93 (sensitivity 89%, specificity 90%). Ex-vivo MRE thus detects reversible, inflammation-driven biomechanical changes, indicating that MRE-derived stiffness may serve as a biomechanical readout of acute intestinal inflammation.

Related

  1. Intraoperative evaluation of spinal cord tension by shear wave elastography (SWE): a biomechanical study on an ovine model
    Tiguida Kadiaké, Sylvain Persohn, Pierre Yves Rohan +4
    Multidisciplinary Biomechanics JournalPeer-reviewedCC BY 4.0Full textMedical imaging & radiologyHAL
  2. In Vivo Cardiac Biomechanical Model Parameter Estimation from Ultrafast Shear Wave Elastography
    Camilla Ferrario, Maelys Venet, Olivier Villemain +1
    Biomechanics and Modeling in MechanobiologyPeer-reviewedCC BY 4.0Full textSystems & synthetic biologyMedical imaging & radiologyHAL
  3. Spatiotemporal evolution of corneal biomechanical properties after cross-linking based on optical coherence elastography.
    Yuqi Liu, Yongkang Zhao, Bi Hu +2
    Frontiers in bioengineering and biotechnologyPeer-reviewedCC BYFull textMedical imaging & radiologyEurope PMCPMC
  4. Ex-Vivo Magnetic Resonance Elastography (MRE) : Assessing Structural Heterogeneity in Meningiomas
    El-Farid Oussen, Franck Jourdan, Valentin Favier +5
    Multidisciplinary Biomechanics JournalPeer-reviewedCC BY 4.0Full textMedical imaging & radiologyHAL
  5. Evaluating the impact of passive driver position on image consistency and repeatability in 3.0T cardiac magnetic resonance elastography
    Jun Wang, Shutian An, Zhen Wang +13
    Frontiers in RadiologyPeer-reviewedCC BY 4.0Full textMedical imaging & radiologyPMCEurope PMC
BibTeX
@article{maisch2026exvivo,
  title = {{Ex-vivo magnetic resonance elastography detects inflammation-associated biomechanical changes in a mouse model of Salmonella-induced colitis}},
  author = {Noah A. Maisch and Anja A. Kühl and Heiko Tzschätzsch and Sari Hussein and Stefan Bereswill and Britta Siegmund and Markus M. Heimesaat and Daniela Paclik},
  journal = {Scientific Reports},
  year = {2026},
  month = oct,
  doi = {10.1038/s41598-026-77433-5},
  url = {https://www.nature.com/articles/s41598-026-77433-5},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Ex-vivo magnetic resonance elastography detects inflammation-associated biomechanical changes in a mouse model of Salmonella-induced colitis
AU  - Noah A. Maisch
AU  - Anja A. Kühl
AU  - Heiko Tzschätzsch
AU  - Sari Hussein
AU  - Stefan Bereswill
AU  - Britta Siegmund
AU  - Markus M. Heimesaat
AU  - Daniela Paclik
PY  - 2026
DA  - 2026/10/26
JO  - Scientific Reports
DO  - 10.1038/s41598-026-77433-5
UR  - https://www.nature.com/articles/s41598-026-77433-5
AB  - Inflammation alters the mechanical properties of soft tissues, yet the biomechanics of the inflamed intestine remain poorly characterized. Using magnetic resonance elastography (MRE), we characterized colonic biomechanical properties in a murine colitis model. CBA/J mice infected with Salmonella Typhimurium were sacrificed at days 5, 16 and 30 post infection alongside uninfected controls. Ex-vivo tabletop MRE and the Springpot model yielded shear modulus µ (stiffness) and powerlaw exponent α (structure). Collagen, hyaluronic acid and periostin content, immune-cell infiltration, epithelial apoptosis and histopathological scoring were assessed histologically. Colonic stiffness decreased at day 5 (1.7 ± 0.7 kPa) versus controls (5.5 ± 4.0 kPa; p = 0.0002), concurrent with development of edema, immune-cell infiltration and apoptosis, without concomitant ECM changes. Stiffness normalized by day 30 and correlated negatively with the histopathological score ( r = − 0.40, p = 0.002) and the total cell count ( r = -0.47, p = 0.002). At day 5, µ discriminated infected from control colons with an AUC of 0.93 (sensitivity 89%, specificity 90%). Ex-vivo MRE thus detects reversible, inflammation-driven biomechanical changes, indicating that MRE-derived stiffness may serve as a biomechanical readout of acute intestinal inflammation.
SN  - 2045-2322
ER  -