Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 35 min ago
PreprintCC BY 4.0arXiv

Where the Error Lives: Separating Lid-Edge and Body-Induced Error in Neural Pressure Prediction for 3D Cavity Flow

Abstract

Can a pressure surrogate score much better globally without better resolving the pressure around immersed bodies? We test this in a three-dimensional lid-driven cavity with an unregularized lid and centered pressure at native 1283 resolution. On 60 cases from 12 unseen geometries, with predictions sealed before the CFD truth existed, adding a body-free, Reynolds-conditioned reference correction to the same frozen 643 surrogate lifted to 1283 lowers the mean full-volume relative L2 error from 20.6% to 7.5%. In the post hoc regional analysis, the lid-edge junction occupies 1.5% of the fluid but holds 69% of the truth pressure energy and 95% of the uncorrected surrogate's squared error. Interior error changes by just +0.16% relative, and object-local peak error and recall change little on average. Retrospective ablations locate the learned term's contribution in the interior and near the bodies; rebasing on the reference lowers global error further with little change in cohort-mean near-body metrics. Reference-relative body-response error remains about 25% in the interior near-body band. Grid-refinement, lid-regularization and convergence checks delimit the numerical scope. In this benchmark, a large global gain chiefly reflects correction of a shared boundary field, not better resolution of the body response. We recommend reporting regional truth-energy and model-error shares alongside near-body and reference-relative body-response errors.

Related

  1. Feedback Control and Neural-Network-Based Prediction of Quantum Entanglement in Fano-mirror cavity optomechanics
    Ya-Feng Jiao, Ze-Yu Zhu, Jie Wang +4
    arXivPreprintarXiv licenceFull textQuantum physics & quantum informationarXiv
  2. Periodic Neural Mapping for Unsteady Rotor-Blade Pressure and Aeroelastic Load Prediction
    Lionel Salesses, Joachim Dominique, Tariq Benamara +2
    arXivPreprintCC BY 4.0Full textFluid dynamicsarXiv
  3. Biomechanical influence of cavity fillers on periwound soft tissue strains in sacral pressure injuries
    Coraline Staub-Milants, Grégory Chagnon, Noémie Briot +2
    Journal of Wound CarePeer-reviewedCC BY 4.0Full textBiological & medical physicsHALarXiv
  4. Beyond Binary Rewrite Decisions: Separating Rewrite-Intensity Control from Level Prediction in a Frozen-LLM Generation-and-Selection Pipeline for Korean Easy-Read Drafting
    Jeong-Eun Lee, Sang Ho Oh
    Applied SciencesPeer-reviewedCC BYFull textGeneral biologyGeneral chemistryDOAJ
  5. Field-Deployable Pressure Standard Based on a Compact Dual-Cavity Refractometer
    Zhong-Liang Nie, Jin Wang, Zi-Fan Zhao +2
    arXivPreprintarXiv licenceFull textOptics & photonicsarXiv
BibTeX
@misc{zhou2026where,
  title = {{Where the Error Lives: Separating Lid-Edge and Body-Induced Error in Neural Pressure Prediction for 3D Cavity Flow}},
  author = {Zirun Zhou and Zhi-Qian Zhang and Yixuan Hong and Guang Liu and Zhigang Liu and Lili Zhang},
  howpublished = {arXiv},
  year = {2026},
  month = nov,
  doi = {10.48550/arxiv.2611.19741},
  eprint = {2611.19741},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2611.19741},
  note = {CC BY 4.0},
}
RIS
TY  - UNPB
TI  - Where the Error Lives: Separating Lid-Edge and Body-Induced Error in Neural Pressure Prediction for 3D Cavity Flow
AU  - Zirun Zhou
AU  - Zhi-Qian Zhang
AU  - Yixuan Hong
AU  - Guang Liu
AU  - Zhigang Liu
AU  - Lili Zhang
PY  - 2026
DA  - 2026/11/15
PB  - arXiv
DO  - 10.48550/arxiv.2611.19741
UR  - https://arxiv.org/abs/2611.19741
AB  - Can a pressure surrogate score much better globally without better resolving the pressure around immersed bodies? We test this in a three-dimensional lid-driven cavity with an unregularized lid and centered pressure at native 128^3 resolution. On 60 cases from 12 unseen geometries, with predictions sealed before the CFD truth existed, adding a body-free, Reynolds-conditioned reference correction to the same frozen 64^3 surrogate lifted to 128^3 lowers the mean full-volume relative L_2 error from 20.6% to 7.5%. In the post hoc regional analysis, the lid-edge junction occupies 1.5% of the fluid but holds 69% of the truth pressure energy and 95% of the uncorrected surrogate's squared error. Interior error changes by just +0.16% relative, and object-local peak error and recall change little on average. Retrospective ablations locate the learned term's contribution in the interior and near the bodies; rebasing on the reference lowers global error further with little change in cohort-mean near-body metrics. Reference-relative body-response error remains about 25% in the interior near-body band. Grid-refinement, lid-regularization and convergence checks delimit the numerical scope. In this benchmark, a large global gain chiefly reflects correction of a shared boundary field, not better resolution of the body response. We recommend reporting regional truth-energy and model-error shares alongside near-body and reference-relative body-response errors.
ER  -