Skip to content
DraconiticResearch
Search Sources API
186,546 studies31 sourcesUpdated 34 min ago
PreprintarXiv licencearXiv

Field-Deployable Pressure Standard Based on a Compact Dual-Cavity Refractometer

Abstract

The next-generation pressure standard is moving toward optical-based, field-deployable systems. However, most existing optical refractometry pressure standards rely on bulky ultra-low expansion (ULE) cavities and complex feedback locking, limiting their portability and on-site applicability. Here, we present a miniaturized, transportable optical pressure manometer based on a dual-channel Fabry-Perot cavity machined from a single block of common fused silica. By employing a differential measurement between an evacuated reference cavity and a gas-exposed measurement cavity, common-mode errors such as thermal expansion and pressure-induced deformation are largely canceled, enabling the use of low-cost fused silica to achieve performance comparable to ULE. Radio-frequency scanning with Lorentzian fitting replaces conventional feedback locking, simplifying the optical design and improving robustness. Calibrated against a piston manometer, the device demonstrates a measurement repeatability of 3.4~ppm and a total uncertainty of u = √((10.6×10−6p)2 + (5.4 mPa)2). The system can resolve periodic pressure fluctuations originating from the piston manometer and exhibits superior response speed. With its small footprint, portability, and independence from external frequency references, this fused-silica dual-cavity manometer offers a practical route toward on-site, quantum-traceable pressure calibration.

Related

  1. A compact, dual-colour chirped-pulse laser system for field-deployable coherent Rayleigh-Brillouin scattering diagnostics
    Yingjie Zhao, Gabriel M. Flores Alfaro, Carmen Pascual-Fort +2
    arXivPreprintarXiv licenceFull textOptics & photonicsarXiv
  2. Compact thermo-optic switch based on graphene-silicon nitride nanobeam cavity
    Yunjie Li, Jingming Chan, Huaixu Chen +3
    Optics ExpressPeer-reviewedPublisher termsOptics & photonicsCrossref
  3. Direct generation of a watt-level single-frequency vortex laser beam via annular pumping in a compact standing-wave cavity
    Zixuan Zhao, Minghao Guo, Xin Yan +5
    Optics ExpressPeer-reviewedLicence not statedOptics & photonicsCrossref
  4. Development of a Prototype Superconducting Radio-Frequency Multicell Cavity for Compact, Conduction-Cooled Accelerators
    J. Vennekate, J. Armstrong, G. Ciovati +7
    arXivPreprintarXiv licenceFull textApplied physics & instrumentationarXiv
  5. Compact, open, and tunable two-dimensional Fabry-Pérot cavity
    Bruno Bender, Andrea Bergschneider, Marcel Baer +2
    arXivPreprintarXiv licenceFull textOptics & photonicsarXiv
BibTeX
@misc{nie2026fielddeployable,
  title = {{Field-Deployable Pressure Standard Based on a Compact Dual-Cavity Refractometer}},
  author = {Zhong-Liang Nie and Jin Wang and Zi-Fan Zhao and Chang-Le Hu and Shui-Ming Hu},
  howpublished = {arXiv},
  year = {2026},
  month = sep,
  doi = {10.48550/arxiv.2609.11964},
  eprint = {2609.11964},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2609.11964},
}
RIS
TY  - UNPB
TI  - Field-Deployable Pressure Standard Based on a Compact Dual-Cavity Refractometer
AU  - Zhong-Liang Nie
AU  - Jin Wang
AU  - Zi-Fan Zhao
AU  - Chang-Le Hu
AU  - Shui-Ming Hu
PY  - 2026
DA  - 2026/09/01
PB  - arXiv
DO  - 10.48550/arxiv.2609.11964
UR  - https://arxiv.org/abs/2609.11964
AB  - The next-generation pressure standard is moving toward optical-based, field-deployable systems. However, most existing optical refractometry pressure standards rely on bulky ultra-low expansion (ULE) cavities and complex feedback locking, limiting their portability and on-site applicability. Here, we present a miniaturized, transportable optical pressure manometer based on a dual-channel Fabry-Perot cavity machined from a single block of common fused silica. By employing a differential measurement between an evacuated reference cavity and a gas-exposed measurement cavity, common-mode errors such as thermal expansion and pressure-induced deformation are largely canceled, enabling the use of low-cost fused silica to achieve performance comparable to ULE. Radio-frequency scanning with Lorentzian fitting replaces conventional feedback locking, simplifying the optical design and improving robustness. Calibrated against a piston manometer, the device demonstrates a measurement repeatability of 3.4~ppm and a total uncertainty of u = √((10.6×10^−6p)^2 + (5.4 mPa)^2). The system can resolve periodic pressure fluctuations originating from the piston manometer and exhibits superior response speed. With its small footprint, portability, and independence from external frequency references, this fused-silica dual-cavity manometer offers a practical route toward on-site, quantum-traceable pressure calibration.
ER  -