Skip to content
DraconiticResearch
Search Sources API
210,089 studies31 sourcesUpdated 25 min ago
Peer-reviewedCC BY 4.0Journal of the American Society for Mass Spectrometry

Titration-Based Assessment of Matrix Effects in Direct Infusion Mass Spectrometry

  1. 1Department of Chemistry for Life Sciences, Uppsala University, 752 37 Uppsala, Sweden
  2. 2Center of Excellence for the Chemical Mechanisms of Life, Uppsala University, 752 37 Uppsala, Sweden

Abstract

Electrospray ionization mass spectrometry (ESI-MS) is a standard and robust technique for analysis of a large variety of biomolecules. Direct infusion approaches offer rapid, high-throughput analysis of small sample volumes but are inherently susceptible to matrix effects during electrospray ionization. These matrix effects can substantially alter analyte ionization and gas-phase response and thereby complicate the interpretation of analyte abundances in complex biological samples. Herein, we developed a titration-based workflow to identify matrix effects and distinguish true changes in endogenous analyte abundance from ionization artifacts using direct infusion probe mass spectrometry (DIP-MS). Rat brain tissue extracts, rat insulinoma cell extracts, and isotopically labeled internal standards were used to model different matrix complexities to define condition-based differences in matrix effects. Thereafter, by mixing paired extracts in different ratios and fitting linear regression models, we assessed analyte-specific responses to sample-specific matrices. Moreover, we uncovered ion suppression or enhancement of hundreds of analytes by comparing regression slopes using interaction tests. We find that using endogenous analytes in our titration-based workflow gives a good indication of matrix effects for certain analyte classes. However, using a preselected panel of internal standards is strongly favorable for reliably identifying matrix effects during ionization. Altogether, combining our titration workflow, a selected panel of internal standards, and regression modeling provides a sensitive way of detecting matrix effects and for distinguishing true metabolite abundance changes from ionization artifacts.

Related

  1. Rapid peptide mapping of monoclonal antibodies with direct infusion mass spectrometry
    Austin Z. Salome, Marcel Morgenstern, Alexander S. Hebert +18
    Communications ChemistryPeer-reviewedCC BY 4.0General chemistryNatureCrossref
  2. Microstructure characterization of self-healing vitrimers via matrix assisted laser desorption/ionization (MALDI) and thermal desorption/pyrolysis direct analysis in real time (TDPy-DART) mass spectrometry (MS) techniques
    Calum Bochenek, Luciana Rivera Molina, Jack Edwards +4
    PolymerPeer-reviewedCC BYFull text1 citedMaterials & polymersHAL
  3. Mass Spectrometry Analysis of Low-Molecular-Weight Sulfur-Containing Metabolites from an Infusion of Scorodophloeus zenkeri Stem Barks
    Ericka Lorleil Mayindza Ekaghba, Simon Ollivier, Hélène Lavanant +6
    MoleculesPeer-reviewedCC BY 4.0General chemistryCrossref
  4. From Innovation to Translation: Emerging Direct-Analysis Mass Spectrometry Platforms.
    Thais Lino, Adriano Reis José da Silva, Davi Rodrigues da Silva +3
    Journal of mass spectrometry : JMSPeer-reviewedCC BYFull textPhysical chemistryEurope PMC
  5. Inside Front Cover: Proximity‐Induced Transfer of a Mass Tag Enables Direct Profiling of Active Matrix Metalloproteases (Angew. Chem. Int. Ed. 24/2026)
    Lomane Berthy, Ugo Pasco, Mylene Sejalon-Cipolla +18
    Angewandte Chemie International EditionPeer-reviewedLicence not statedFull textPhysical chemistryHAL
BibTeX
@article{persson2026titrationbased,
  title = {{Titration-Based Assessment of Matrix Effects in Direct Infusion Mass Spectrometry}},
  author = {Pontus Persson and Gabor Toth and Natália Remper and Lucie Davidová and Ingela Lanekoff},
  journal = {Journal of the American Society for Mass Spectrometry},
  year = {2026},
  month = oct,
  doi = {10.1021/jasms.6c00220},
  url = {https://doi.org/10.1021/jasms.6c00220},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Titration-Based Assessment of Matrix Effects in Direct Infusion Mass Spectrometry
AU  - Pontus Persson
AU  - Gabor Toth
AU  - Natália Remper
AU  - Lucie Davidová
AU  - Ingela Lanekoff
PY  - 2026
DA  - 2026/10/24
JO  - Journal of the American Society for Mass Spectrometry
DO  - 10.1021/jasms.6c00220
UR  - https://doi.org/10.1021/jasms.6c00220
AB  - Electrospray ionization mass spectrometry (ESI-MS) is a standard and robust technique for analysis of a large variety of biomolecules. Direct infusion approaches offer rapid, high-throughput analysis of small sample volumes but are inherently susceptible to matrix effects during electrospray ionization. These matrix effects can substantially alter analyte ionization and gas-phase response and thereby complicate the interpretation of analyte abundances in complex biological samples. Herein, we developed a titration-based workflow to identify matrix effects and distinguish true changes in endogenous analyte abundance from ionization artifacts using direct infusion probe mass spectrometry (DIP-MS). Rat brain tissue extracts, rat insulinoma cell extracts, and isotopically labeled internal standards were used to model different matrix complexities to define condition-based differences in matrix effects. Thereafter, by mixing paired extracts in different ratios and fitting linear regression models, we assessed analyte-specific responses to sample-specific matrices. Moreover, we uncovered ion suppression or enhancement of hundreds of analytes by comparing regression slopes using interaction tests. We find that using endogenous analytes in our titration-based workflow gives a good indication of matrix effects for certain analyte classes. However, using a preselected panel of internal standards is strongly favorable for reliably identifying matrix effects during ionization. Altogether, combining our titration workflow, a selected panel of internal standards, and regression modeling provides a sensitive way of detecting matrix effects and for distinguishing true metabolite abundance changes from ionization artifacts.
SN  - 1044-0305
SN  - 1879-1123
ER  -