Associated factors of elastic and stiffening components of pulse pressure based on 45 517 database of 24 h ambulatory blood pressure monitoring
13 affiliations
- 1Győr-Moson-Sopron County Petz Aladár University Teaching Hospital, IV. Department of Internal Medicine, Győr, Hungary
- 2South-Buda Center Hospital St. Imre University Teaching Hospital, Department of Cardiology, Budapest, Hungary
- 3Department of Social Sciences, Semmelweis University, Budapest, Hungary
- 4Department of Medicine, University of Debrecen, Debrecen, Hungary
- 5Department of Medical Clinical Pharmacology, University of Debrecen, Debrecen, Hungary
- 6Department of Family Medicine, Semmelweis University, Budapest, Hungary
- 7Research Center for Sport Physiology, Hungarian University of Sports Science, Budapest, Hungary
- 8Departments of Morphology & Physiology and Translational Medicine, Budapest, Hungary
- 9Department of Cell and Molecular Physiology, New York Medical College, Valhalla, NY USA
- 10Division of Metabolic Diseases, Department of Internal Medicine, University of Debrecen Faculty of Medicine, Debrecen, Hungary
- 11ELKH-UD Vascular Pathophysiology Research Group, University of Debrecen, Debrecen, Hungary
- 12Institute of Health Studies, Faculty of Health Sciences, University of Debrecen, Debrecen, Hungary
- 13Section of Angiology, Városmajor Heart and Vascular Center, Semmelweis University, Budapest, Hungary
Abstract
Pulse pressure (PP), which has been proposed to be a marker of hypertension-mediated organ damage (HMOD) in elderly, can be divided into two components: elastic PP (elPP) and stiffening PP (stPP). Thus, the aim of our study was to explore the associated factors of 24 h elPP and stPP. ABPM data of 45 517 subjects (age: 56.4 ± 14.9 years, male: 20 897 (45.9%)) were collected from the Hungarian ABPM Registry between September 2020 and August 2024. Subjects’ clinical data were analyzed together with ABPM curves. elPP and stPP were calculated according to published formulas. The elPP was higher in men than in women (46.4 ± 8.2 vs 45.8 ± 9.2 mmHg, p < 0.05), whereas stPP was higher in women than in men (8.9 ± 5.8 vs 8.3 ± 5.5 mmHg, p < 0.05). elPP showed a U-shaped curve with age, which had a higher value below 40 years (47.3 ± 8 mmHg), then it decreased between 40–49 and 50–59 years (43.7 ± 7.3 and 43.9 ± 8 mmHg, respectively) and it increased again reaching 49.4 ± 9.7 mmHg above the age >70 years, while stPP progressively increased with ageing. Multiple correlates of elPP and stPP were identified based on age groups, sex, heart rate and antihypertensive medication. In conclusions, the evaluation of the associated factors of elPP and stPP and of elPP decrease in middle-aged subjects can help to better understand the pathomechanisms responsible for the development of HMOD and the role of pulse pressure in the prediction of CV outcome.
Related
- Association of 24 h Pulse Pressure Derived from Ambulatory Blood Pressure Monitoring with All-Cause and Cardiovascular Mortality in Patients Undergoing Peritoneal Dialysis: A Prospective Cohort Study
- Validation of the Detection of The Salt Sensitivity of Blood Pressure from 24-hour Ambulatory Blood Pressure Monitoring Data
- Optical coherence tomography angiography findings in newly diagnosed hypertension patients with 24-h ambulatory blood pressure monitoring
- Compare 30-minute automated office blood pressure vs 24-hour ambulatory blood pressure monitoring: A prospective study
- Ambulatory Blood Pressure Monitoring in Adults with Congenital Heart Disease
BibTeX
@article{kekk2026associated,
title = {{Associated factors of elastic and stiffening components of pulse pressure based on 45 517 database of 24 h ambulatory blood pressure monitoring}},
author = {Zsófia Kekk and Dorottya Pásztor and Johanna Takács and Dénes Páll and Zsófia Jósvai and Péter Torzsa and Akos Koller and Mariann Harangi and Zoltán Járai and János Nemcsik},
journal = {Journal of Human Hypertension},
year = {2026},
month = aug,
doi = {10.1038/s41371-026-01210-0},
url = {https://doi.org/10.1038/s41371-026-01210-0},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - Associated factors of elastic and stiffening components of pulse pressure based on 45 517 database of 24 h ambulatory blood pressure monitoring
AU - Zsófia Kekk
AU - Dorottya Pásztor
AU - Johanna Takács
AU - Dénes Páll
AU - Zsófia Jósvai
AU - Péter Torzsa
AU - Akos Koller
AU - Mariann Harangi
AU - Zoltán Járai
AU - János Nemcsik
PY - 2026
DA - 2026/08/26
JO - Journal of Human Hypertension
DO - 10.1038/s41371-026-01210-0
UR - https://doi.org/10.1038/s41371-026-01210-0
AB - Pulse pressure (PP), which has been proposed to be a marker of hypertension-mediated organ damage (HMOD) in elderly, can be divided into two components: elastic PP (elPP) and stiffening PP (stPP). Thus, the aim of our study was to explore the associated factors of 24 h elPP and stPP. ABPM data of 45 517 subjects (age: 56.4 ± 14.9 years, male: 20 897 (45.9%)) were collected from the Hungarian ABPM Registry between September 2020 and August 2024. Subjects’ clinical data were analyzed together with ABPM curves. elPP and stPP were calculated according to published formulas. The elPP was higher in men than in women (46.4 ± 8.2 vs 45.8 ± 9.2 mmHg, p < 0.05), whereas stPP was higher in women than in men (8.9 ± 5.8 vs 8.3 ± 5.5 mmHg, p < 0.05). elPP showed a U-shaped curve with age, which had a higher value below 40 years (47.3 ± 8 mmHg), then it decreased between 40–49 and 50–59 years (43.7 ± 7.3 and 43.9 ± 8 mmHg, respectively) and it increased again reaching 49.4 ± 9.7 mmHg above the age >70 years, while stPP progressively increased with ageing. Multiple correlates of elPP and stPP were identified based on age groups, sex, heart rate and antihypertensive medication. In conclusions, the evaluation of the associated factors of elPP and stPP and of elPP decrease in middle-aged subjects can help to better understand the pathomechanisms responsible for the development of HMOD and the role of pulse pressure in the prediction of CV outcome.
SN - 0950-9240
SN - 1476-5527
ER -