Comparative host–graft biomechanics of osteoarticular allografts and allograft–prosthesis composites after distal femoral tumor resection

  1. 1First Department of Orthopaedic Surgery, St. Anne’s University Hospital and Faculty of Medicine, Masaryk University
  2. 2Institute of Solid Mechanics, Mechatronics and Biomechanics, Faculty of Mechanical Engineering, Brno University of Technology

Abstract

Background Distal femoral reconstruction after tumor resection can be performed using osteoarticular allografts (OCH) or allograft–prosthesis composites (APC). Although both techniques restore bone stock, complications such as nonunion, graft fracture, and hardware failure remain frequent. These events are closely related to the mechanical environment at the host–graft junction, yet direct biomechanical comparison under identical conditions is limited. Therefore, this study aimed to compare the mechanical behavior of OCH and APC reconstructions following distal femoral tumor resection using finite element analysis, focusing on graft strain, hardware stress, and interfragmentary motion (IFM). Methods Two patient-specific finite element models were created from CT data, simulating a 150-mm distal femoral defect reconstructed either with a plate-fixed osteoarticular allograft (OCH) or with a cemented revision rotating-hinge allograft–prosthesis composite (APC). A 400 N axial load was applied to represent early postoperative weight bearing. Equivalent strain, von Mises stress, IFM, and sliding distance at the host–graft interface were quantified. Results OCH demonstrated higher peak graft strain (5700 µε vs. 3200 µε) and increased IFM (median 6.5 μm vs. 2.5 μm) compared with APC. Hardware stress was 77 MPa in OCH and 24 MPa in APC. Sliding distance was also greater in OCH (3.5 μm vs. 0.6 μm). APC showed reduced graft strain and micromotion consistent with load redistribution through the prosthetic stem and cement mantle. Conclusion Under identical geometry and early postoperative loading conditions, OCH and APC reconstructions demonstrated distinct load-transfer patterns. OCH was associated with greater graft strain and micromotion, whereas APC demonstrated lower graft strain and greater construct rigidity. Rather than indicating superiority, the findings highlight that each reconstruction is governed by a characteristic mechanical environment that may influence its failure pattern.

Related

  1. Anterior Lumbar Interbody Fusion Versus Total Disc Replacement with a Viscoelastic Prosthesis for Single-Level Lumbar Degenerative Disc Disease in Young Adults: A Comparative Retrospective Cohort Study
    Clément Jacquemin, Matthieu Campana, Jean-Etienne Castelain +3
    Journal of clinical medicinePeer-reviewedCC BYFull textGeneral medicineEurope PMC
  2. Comparative Rheological Characterization of Hyaluronic Acid Viscosupplements for Synovial Fluid Restoration in Osteoarthritis and Knee Biomechanics.
    Alejandro Melero, Ander Pino, José María Alonso +5
    Gels (Basel, Switzerland)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
  3. Genetic control of bone marrow transplantation in irradiated mice: classification of mouse strains according to their responsiveness to bone marrow allografts and xenografts
    Eva Lotzová, Dicke Ka, John J. Trentin +1
    PubMedPeer-reviewedLicence not stated18 citedGeneral medicineOpenAlex
  4. Staged limb salvage after an infected full-thickness shoulder-girdle flame burn with osteoarticular exposure in an elderly patient : A case report with 3.5-year follow-up
    Nguyen Ngoc-Huyen, Nguyen The-Hoang, Nguyen Quang-Vinh +1
    MedicinePeer-reviewedCC BYFull textGeneral medicineEurope PMC
  5. Microleakage of Class II resin composite restorations restored with conventional, bulk-fill, and short fiber-reinforced composites with or without polyethylene fiber reinforcement: a comparative in vitro study.
    Saeede Asdagh, Mahdi Rahbar, Sajede Hoseininezhad +1
    BMC oral healthPeer-reviewedCC BY-NC-NDFull text1 citedGeneral medicineEurope PMCDOAJ
BibTeX
@article{apostolopoulos2026comparative,
  title = {{Comparative host–graft biomechanics of osteoarticular allografts and allograft–prosthesis composites after distal femoral tumor resection}},
  author = {Vasileios Apostolopoulos and Petr Boháč and Michal Mahdal and Luboš Nachtnebl and Tomáš Návrat and Tomáš Tomáš},
  journal = {Journal of Orthopaedic Surgery and Research},
  year = {2026},
  month = aug,
  doi = {10.1186/s13018-026-07127-1},
  url = {https://doi.org/10.1186/s13018-026-07127-1},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Comparative host–graft biomechanics of osteoarticular allografts and allograft–prosthesis composites after distal femoral tumor resection
AU  - Vasileios Apostolopoulos
AU  - Petr Boháč
AU  - Michal Mahdal
AU  - Luboš Nachtnebl
AU  - Tomáš Návrat
AU  - Tomáš Tomáš
PY  - 2026
DA  - 2026/08/01
JO  - Journal of Orthopaedic Surgery and Research
DO  - 10.1186/s13018-026-07127-1
UR  - https://doi.org/10.1186/s13018-026-07127-1
AB  - Background Distal femoral reconstruction after tumor resection can be performed using osteoarticular allografts (OCH) or allograft–prosthesis composites (APC). Although both techniques restore bone stock, complications such as nonunion, graft fracture, and hardware failure remain frequent. These events are closely related to the mechanical environment at the host–graft junction, yet direct biomechanical comparison under identical conditions is limited. Therefore, this study aimed to compare the mechanical behavior of OCH and APC reconstructions following distal femoral tumor resection using finite element analysis, focusing on graft strain, hardware stress, and interfragmentary motion (IFM). Methods Two patient-specific finite element models were created from CT data, simulating a 150-mm distal femoral defect reconstructed either with a plate-fixed osteoarticular allograft (OCH) or with a cemented revision rotating-hinge allograft–prosthesis composite (APC). A 400 N axial load was applied to represent early postoperative weight bearing. Equivalent strain, von Mises stress, IFM, and sliding distance at the host–graft interface were quantified. Results OCH demonstrated higher peak graft strain (5700 µε vs. 3200 µε) and increased IFM (median 6.5 μm vs. 2.5 μm) compared with APC. Hardware stress was 77 MPa in OCH and 24 MPa in APC. Sliding distance was also greater in OCH (3.5 μm vs. 0.6 μm). APC showed reduced graft strain and micromotion consistent with load redistribution through the prosthetic stem and cement mantle. Conclusion Under identical geometry and early postoperative loading conditions, OCH and APC reconstructions demonstrated distinct load-transfer patterns. OCH was associated with greater graft strain and micromotion, whereas APC demonstrated lower graft strain and greater construct rigidity. Rather than indicating superiority, the findings highlight that each reconstruction is governed by a characteristic mechanical environment that may influence its failure pattern.
SN  - 1749-799X
ER  -