Skip to content
DraconiticResearch
Search Sources API
203,234 studies31 sourcesUpdated 46 min ago
Peer-reviewedCC BY-NC-NDBMC oral health

Microleakage of Class II resin composite restorations restored with conventional, bulk-fill, and short fiber-reinforced composites with or without polyethylene fiber reinforcement: a comparative in vitro study.

  1. 1Department of Restorative Dentistry, School of Dentistry, Ardabil University of Medical Sciences, Ardabil, Iran.
  2. 2Department of Restorative Dentistry, School of Dentistry, Ardabil University of Medical Sciences, Ardabil, Iran. [email protected].
  3. 3Department of Community Medicine, School of Medicine, Ardabil University of Medical Sciences, Ardabil, Iran. [email protected].

Abstract

Background

Microleakage remains a major concern in Class II resin composite restorations and is associated with postoperative sensitivity, marginal discoloration, secondary caries, and restoration failure. Various strategies, including the use of bulk-fill composites and fiber reinforcement, have been proposed to reduce polymerization shrinkage stress and improve marginal sealing. This study aimed to evaluate the effect of composite type and polyethylene fiber reinforcement on the microleakage of Class II resin composite restorations.Methods

This in vitro study was conducted on 40 extracted human premolars randomly assigned to five groups (n = 8): conventional composite, conventional composite with polyethylene fiber, bulk-fill composite, bulk-fill composite with polyethylene fiber, and short fiber-reinforced composite (SFRC). Standardized Class II cavities were restored according to the respective protocols. Following thermocycling (500 cycles, 5-55 °C), microleakage was evaluated using 2% methylene blue dye penetration under a stereomicroscope (×10). Data were analyzed using the Kruskal-Wallis test followed by Dunn's post hoc test (α = 0.05).Results

A significant difference in microleakage scores was observed among the study groups (P < 0.001). The bulk-fill composite group demonstrated the highest microleakage scores, whereas the SFRC group showed the lowest scores. Polyethylene fiber reinforcement reduced microleakage in both conventional and bulk-fill composites. Significantly higher microleakage was observed in the bulk-fill composite group than in the conventional composite reinforced with polyethylene fiber (CPF) and SFRC groups. No statistically significant difference was observed between SFRC and conventional composite reinforced with polyethylene fiber.Conclusions

Composite type significantly influenced microleakage in Class II restorations. Short fiber-reinforced composite demonstrated the most favorable marginal sealing performance among the evaluated materials. Polyethylene fiber reinforcement was associated with a reduction in microleakage, although the magnitude of improvement varied according to the restorative material.

Related

  1. Twenty-Year Wear Progression and Long-Term Outcomes of Conventional Polyethylene Liners After Cementless Total Hip Arthroplasty
    Yasutaka Watanabe, Toru Moro, Hisatoshi Ishikura +3
    Arthroplasty todayPeer-reviewedCC BY-NC-NDFull textSurgery & anaesthesiaEurope PMC
  2. Twenty-Year Wear Progression and Long-Term Outcomes of Conventional Polyethylene Liners After Cementless Total Hip Arthroplasty
    Yasutaka Watanabe, MD, Toru Moro, MD, PhD, Hisatoshi Ishikura, MD, PhD +3
    Arthroplasty TodayPeer-reviewedCC BY-NC-NDFull textSurgery & anaesthesiaDOAJEurope PMCPMC
  3. Evaluation of Tooth Shade Selection With Conventional Methods and Artificial Intelligence-Integrated Methods: A Comparative Study
    Rahul Das, Sheenam Markan, Mukesh Kumar +3
    CureusPeer-reviewedCC BYFull textGeneral medicineEurope PMC
  4. Comparison of Hockey-Stick and Conventional Linear Ultrasound Transducers for Detection of Non-Displaced Dentoalveolar Fractures: An Ex Vivo Paired Comparative Study
    Murat Mert Atapek, Sedef Ayşe Taşyapan, Elif Yıldızer
    TomographyPeer-reviewedCC BYFull textMedical imaging & radiologyEurope PMC
  5. Muscle-Preserving Versus Conventional Midline Expansive Open-Door Laminoplasty for Multilevel Cervical Spondylotic Myelopathy: A 10-Year Comparative Cohort Study
    Hao-Wen Chen, Kuang-Ting Yeh, Wen-Tien Wu
    Medicina (Kaunas, Lithuania)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
BibTeX
@article{asdagh2026microleakage,
  title = {{Microleakage of Class II resin composite restorations restored with conventional, bulk-fill, and short fiber-reinforced composites with or without polyethylene fiber reinforcement: a comparative in vitro study.}},
  author = {Saeede Asdagh and Mahdi Rahbar and Sajede Hoseininezhad and Aziz Kamran},
  journal = {BMC oral health},
  year = {2026},
  month = jul,
  doi = {10.1186/s12903-026-09429-6},
  url = {https://europepmc.org/article/MED/42919268},
  note = {CC BY-NC-ND},
}
RIS
TY  - JOUR
TI  - Microleakage of Class II resin composite restorations restored with conventional, bulk-fill, and short fiber-reinforced composites with or without polyethylene fiber reinforcement: a comparative in vitro study.
AU  - Saeede Asdagh
AU  - Mahdi Rahbar
AU  - Sajede Hoseininezhad
AU  - Aziz Kamran
PY  - 2026
DA  - 2026/07/01
JO  - BMC oral health
DO  - 10.1186/s12903-026-09429-6
UR  - https://europepmc.org/article/MED/42919268
AB  - Background  Microleakage remains a major concern in Class II resin composite restorations and is associated with postoperative sensitivity, marginal discoloration, secondary caries, and restoration failure. Various strategies, including the use of bulk-fill composites and fiber reinforcement, have been proposed to reduce polymerization shrinkage stress and improve marginal sealing. This study aimed to evaluate the effect of composite type and polyethylene fiber reinforcement on the microleakage of Class II resin composite restorations.Methods  This in vitro study was conducted on 40 extracted human premolars randomly assigned to five groups (n = 8): conventional composite, conventional composite with polyethylene fiber, bulk-fill composite, bulk-fill composite with polyethylene fiber, and short fiber-reinforced composite (SFRC). Standardized Class II cavities were restored according to the respective protocols. Following thermocycling (500 cycles, 5-55 °C), microleakage was evaluated using 2% methylene blue dye penetration under a stereomicroscope (×10). Data were analyzed using the Kruskal-Wallis test followed by Dunn's post hoc test (α = 0.05).Results  A significant difference in microleakage scores was observed among the study groups (P < 0.001). The bulk-fill composite group demonstrated the highest microleakage scores, whereas the SFRC group showed the lowest scores. Polyethylene fiber reinforcement reduced microleakage in both conventional and bulk-fill composites. Significantly higher microleakage was observed in the bulk-fill composite group than in the conventional composite reinforced with polyethylene fiber (CPF) and SFRC groups. No statistically significant difference was observed between SFRC and conventional composite reinforced with polyethylene fiber.Conclusions  Composite type significantly influenced microleakage in Class II restorations. Short fiber-reinforced composite demonstrated the most favorable marginal sealing performance among the evaluated materials. Polyethylene fiber reinforcement was associated with a reduction in microleakage, although the magnitude of improvement varied according to the restorative material.
SN  - 1472-6831
ER  -