A method for correcting background non-uniformity while preserving specimen-level information in Fourier ptychographic microscopy images

  1. 1University of Strathclyde

Abstract

Fourier ptychographic microscopy (FPM) enables high resolution imaging across large fields of view, but reconstructed images often exhibit background non-uniformity that interferes with quantitative image analysis. Here, a post-reconstruction background correction approach is presented that identifies specimen-containing regions and corrects only the surrounding background, leaving specimen pixel intensities unchanged. The method was effective across amplitude and phase reconstructions of multiple biological specimen types with no loss in image resolution. The method also improved object detection compared with analysis of the uncorrected image data. FPM background correction reduced residual background non-uniformity to 0.61% with only 0.04% structural error, compared with 6.13% structural error for pseudo flat field correction. These results demonstrate that FPM background correction can support more accurate quantitative analysis of FPM image data while preserving specimen information and image resolution, enabling more reliable segmentation and measurement across large fields of view.

Related

  1. Preserving topographic information stored on DNA origami nanostructures in harsh environments by ultrathin Al2O3 films
    Xinyang Li, Marcel Hanke, Sandra Gołębiowska +3
    ChemRxivPreprintCC BYFull textMolecular biology & gene regulationChemRxiv
  2. End-to-end reconstruction for cryo electron ptychographic single-particle analysis
    S. You, N. Palatkin, S. Shao +1
    bioRxivPreprintCC BYFull textBiophysicsbioRxiv
  3. Comparison of Prime Editing and CRISPR-Cas Mediated HDR in Correcting CFTR-F508del Mutation in Patient iPSC-Derived Airway Basal Cells
    Olga Volodina, Anna Demchenko, Ekaterina Kondrateva +8
    International journal of molecular sciencesPeer-reviewedCC BYFull textGeneral biochemistryEurope PMC
  4. Correcting Multiple Scattering Enables Dynamical Electron Crystallography in Standard Workflows
    D. R. Hopkins, T. Low-Beer, Z. Ding +7
    bioRxivPreprintCC BYFull textBiophysicsbioRxiv
  5. Correcting the Dropout-LayerNorm Expectation Gap Improves Protein Structure Models
    Isaac Ellmen, David Errington, Matthew I. J. Raybould +1
    arXivPreprintCC BY 4.0Full textBiophysicsarXiv
BibTeX
@misc{copeland2026method,
  title = {{A method for correcting background non-uniformity while preserving specimen-level information in Fourier ptychographic microscopy images}},
  author = {L. Copeland and K. F. E. Polland and L. Walker and W. B. Amos and K. J. Baxter and M. J. Shaw and G. McConnell},
  howpublished = {bioRxiv},
  year = {2026},
  month = oct,
  doi = {10.64898/2026.10.21.760683},
  url = {https://www.biorxiv.org/content/10.64898/2026.10.21.760683v1},
  note = {CC BY-ND},
}
RIS
TY  - UNPB
TI  - A method for correcting background non-uniformity while preserving specimen-level information in Fourier ptychographic microscopy images
AU  - L. Copeland
AU  - K. F. E. Polland
AU  - L. Walker
AU  - W. B. Amos
AU  - K. J. Baxter
AU  - M. J. Shaw
AU  - G. McConnell
PY  - 2026
DA  - 2026/10/21
PB  - bioRxiv
DO  - 10.64898/2026.10.21.760683
UR  - https://www.biorxiv.org/content/10.64898/2026.10.21.760683v1
AB  - Fourier ptychographic microscopy (FPM) enables high resolution imaging across large fields of view, but reconstructed images often exhibit background non-uniformity that interferes with quantitative image analysis. Here, a post-reconstruction background correction approach is presented that identifies specimen-containing regions and corrects only the surrounding background, leaving specimen pixel intensities unchanged. The method was effective across amplitude and phase reconstructions of multiple biological specimen types with no loss in image resolution. The method also improved object detection compared with analysis of the uncorrected image data. FPM background correction reduced residual background non-uniformity to 0.61% with only 0.04% structural error, compared with 6.13% structural error for pseudo flat field correction. These results demonstrate that FPM background correction can support more accurate quantitative analysis of FPM image data while preserving specimen information and image resolution, enabling more reliable segmentation and measurement across large fields of view.