First‐Trimester Cell‐Free DNA Screening for Common Trisomies Using Rolling‐Circle Amplification: A Prospective Study
5 affiliations
- 1Department of Obstetrics and Gynecology “Virgen de la Arrixaca” University Hospital Murcia Spain
- 2Department of Obstetrics and Gynecology, Pediatrics and Surgery University of Murcia Murcia Spain
- 3Maternal‐Fetal Medicine Reproduction and Gynecology Research Group Biomedical Research Institute of Murcia Pascual Parrilla–IMIB Murcia Spain
- 4Vanadis Diagnostics AB, a Revvity Inc Company Sollentuna Sweden
- 5Fetal Medicine Research Institute King's College Hospital London UK
Abstract
Objective: To evaluate cell‐free DNA screening for trisomies 21, 18 and 13 using rolling circle replication in an unselected routine first‐trimester screening population.
Method: This study enrolled 3025 women undergoing first‐trimester screening. Excluding unavailable samples, missing outcome data, pregnancy loss and twin gestation, 2729 pregnancies with follow‐up remained; 2689 had cell‐free DNA results for performance analysis. Cell‐free fetal DNA was assessed by rolling circle replication and digital fluorescence detection without PCR or sequencing. Performance was confirmed with cytogenetic results or postnatal outcomes.
Results: Among 2729 eligible singleton pregnancies with follow‐up, valid cfDNA results were obtained in 2689 cases, corresponding to an overall no‐call rate of 40/2729 (1.47%). For trisomy 21, sensitivity was 14/14 (100%; 95% CI, 76.8–100), specificity was 2666/2675 (99.7%; 95% CI, 99.4–99.8), and PPV was 14/23 (60.9%; 95% CI, 38.5–80.3). For trisomy 18, sensitivity was 1/2 (50.0%; 95% CI, 1.3–98.7), specificity was 2681/2687 (99.8%; 95% CI, 99.5–99.9), and PPV was 1/7 (14.3%; 95% CI, 0.4–57.9). No confirmed trisomy 13 cases were observed. Fetal sex was correctly assigned in 2657/2688 cases (98.8%). Testing before 10 weeks' gestation and in IVF pregnancies appeared technically feasible, but these subgroup findings were limited by small numbers.
Conclusions: Rolling circle replication‐based cell‐free DNA screening showed high accuracy for trisomy 21 and fetal sex determination in this unselected routine first‐trimester screening population. However, the small number of trisomy 18 and trisomy 13 cases limits conclusions for these aneuploidies.
Related
- Structural Fetal Anomalies Identified During First-Trimester Screening: A Single-Centre Experience in Romania
- Mapping Preeclampsia Risk Thresholds to Screen-Positive Rates in Routine First-Trimester Screening: A Single-Centre Audit
- Clinical Significance of Abnormal First-Trimester Chorionic Villus Sampling After Mosaic Embryo Transfer: A Prospective Study with Confirmatory Amniocentesis
- Comparative efficacy of “Superimposed Line” sign and maxillary gap in first-trimester screening for cleft palate: a retrospective case-control study
- Should glucose screening be repeated for large-for-gestational-age fetuses in the third trimester of non-diabetic pregnancies? A scoping review.
BibTeX
@article{matallana2026firsttrimester,
title = {{First‐Trimester Cell‐Free DNA Screening for Common Trisomies Using Rolling‐Circle Amplification: A Prospective Study}},
author = {Catalina De Paco Matallana and Javier Sánchez Romero and Miriam Pertegal and Juan Luis Delgado and Erica Ramfjord and Kypros H. Nicolaides},
journal = {Prenatal Diagnosis},
year = {2026},
month = oct,
doi = {10.1002/pd.70260},
url = {https://doi.org/10.1002/pd.70260},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - First‐Trimester Cell‐Free DNA Screening for Common Trisomies Using Rolling‐Circle Amplification: A Prospective Study
AU - Catalina De Paco Matallana
AU - Javier Sánchez Romero
AU - Miriam Pertegal
AU - Juan Luis Delgado
AU - Erica Ramfjord
AU - Kypros H. Nicolaides
PY - 2026
DA - 2026/10/13
JO - Prenatal Diagnosis
DO - 10.1002/pd.70260
UR - https://doi.org/10.1002/pd.70260
AB - Objective: To evaluate cell‐free DNA screening for trisomies 21, 18 and 13 using rolling circle replication in an unselected routine first‐trimester screening population. Method: This study enrolled 3025 women undergoing first‐trimester screening. Excluding unavailable samples, missing outcome data, pregnancy loss and twin gestation, 2729 pregnancies with follow‐up remained; 2689 had cell‐free DNA results for performance analysis. Cell‐free fetal DNA was assessed by rolling circle replication and digital fluorescence detection without PCR or sequencing. Performance was confirmed with cytogenetic results or postnatal outcomes. Results: Among 2729 eligible singleton pregnancies with follow‐up, valid cfDNA results were obtained in 2689 cases, corresponding to an overall no‐call rate of 40/2729 (1.47%). For trisomy 21, sensitivity was 14/14 (100%; 95% CI, 76.8–100), specificity was 2666/2675 (99.7%; 95% CI, 99.4–99.8), and PPV was 14/23 (60.9%; 95% CI, 38.5–80.3). For trisomy 18, sensitivity was 1/2 (50.0%; 95% CI, 1.3–98.7), specificity was 2681/2687 (99.8%; 95% CI, 99.5–99.9), and PPV was 1/7 (14.3%; 95% CI, 0.4–57.9). No confirmed trisomy 13 cases were observed. Fetal sex was correctly assigned in 2657/2688 cases (98.8%). Testing before 10 weeks' gestation and in IVF pregnancies appeared technically feasible, but these subgroup findings were limited by small numbers. Conclusions: Rolling circle replication‐based cell‐free DNA screening showed high accuracy for trisomy 21 and fetal sex determination in this unselected routine first‐trimester screening population. However, the small number of trisomy 18 and trisomy 13 cases limits conclusions for these aneuploidies.
SN - 0197-3851
SN - 1097-0223
ER -