Analytical model enabling the correction of absorption and scattering in dual-color ratiometric multiphoton microscopy of brain tissue
Abstract
Significance: Multiphoton microscopy with fluorescent indicators enables the monitoring of biomarker dynamics through changes in fluorescence intensity. However, quantitative interpretation remains challenging because fluorescence signals are highly sensitive to experimental conditions. Dual-color ratiometric approaches improve quantification, yet wavelength-dependent absorption and scattering of emitted photons can still introduce significant bias. Aim: This study aimed to develop a correction method for absorption and scattering effects to achieve unbiased dual-color ratiometric measurements in multiphoton microscopy. Approach: We developed an analytical model that incorporates the spectral optical properties of biological tissues and fluorophores. The model was applied to the rodent cerebral cortex parenchyma and to the lumen of individual blood vessels. Its predictions were evaluated using simulations and in vivo two-photon microscopy experiments. Results: In the cerebral cortex parenchyma, absorption and scattering bias dual-color ratiometric measurements by up to ∼100% at depths of approximately ∼400 μm. Our model accurately describes and corrects these effects. Within the vessel lumen, however, the situation is more complex: the model effectively corrects the biases in veins, but not in arterioles. Conclusions: Overall, the proposed model enhances the accuracy of biomarker quantification in multiphoton microscopy and provides practical tools for correcting optical biases in biological tissues.
Related
- A DNA-tetrahedron-gated HCR strategy on CsPbBr₃@PDA@AuNPs for ratiometric ECL/SERS determination of Aflatoxin B1
- Multiphoton tomographic fluorescence lifetime imaging microscopy -TomoFLIM
- FRACTAL: A Ratiometric-based Fingerprinting Framework for Robust Spectral Classification and Ratio-based Spectroscopic Marker Discovery
- Development of CRISPR/Cas13-based analytical tools to study RNA–protein interactions
- Biological Accessibility and Analytical Recovery in Myofibrillar Protein Loss During Skeletal Muscle Atrophy
BibTeX
@article{chaigneau2026analytical,
title = {{Analytical model enabling the correction of absorption and scattering in dual-color ratiometric multiphoton microscopy of brain tissue}},
author = {Emmanuelle M Chaigneau and Marine Tournissac and Sophie Walter and Mayeul Collot and Serge Charpak},
journal = {Neurophotonics},
year = {2026},
month = sep,
doi = {10.1117/1.nph.13.3.035007},
url = {https://hal.science/hal-05768923v1},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - Analytical model enabling the correction of absorption and scattering in dual-color ratiometric multiphoton microscopy of brain tissue
AU - Emmanuelle M Chaigneau
AU - Marine Tournissac
AU - Sophie Walter
AU - Mayeul Collot
AU - Serge Charpak
PY - 2026
DA - 2026/09/03
JO - Neurophotonics
DO - 10.1117/1.nph.13.3.035007
UR - https://hal.science/hal-05768923v1
AB - Significance: Multiphoton microscopy with fluorescent indicators enables the monitoring of biomarker dynamics through changes in fluorescence intensity. However, quantitative interpretation remains challenging because fluorescence signals are highly sensitive to experimental conditions. Dual-color ratiometric approaches improve quantification, yet wavelength-dependent absorption and scattering of emitted photons can still introduce significant bias. Aim: This study aimed to develop a correction method for absorption and scattering effects to achieve unbiased dual-color ratiometric measurements in multiphoton microscopy. Approach: We developed an analytical model that incorporates the spectral optical properties of biological tissues and fluorophores. The model was applied to the rodent cerebral cortex parenchyma and to the lumen of individual blood vessels. Its predictions were evaluated using simulations and in vivo two-photon microscopy experiments. Results: In the cerebral cortex parenchyma, absorption and scattering bias dual-color ratiometric measurements by up to ∼100% at depths of approximately ∼400 μm. Our model accurately describes and corrects these effects. Within the vessel lumen, however, the situation is more complex: the model effectively corrects the biases in veins, but not in arterioles. Conclusions: Overall, the proposed model enhances the accuracy of biomarker quantification in multiphoton microscopy and provides practical tools for correcting optical biases in biological tissues.
SN - 2329-423X
SN - 2329-4248
ER -