Compressive microendoscopy in the presence of noise and misalignment: the translational correlation advantage of graded-index fibers

Abstract

Multimode fibers (MMFs) offer a minimally invasive platform for deep-tissue and multisite in vivo optical sensing. Computational microendoscopy methods extend them into the high-resolution imaging domain, but are quite sensitive to experimental errors. This study investigates the robustness of microendoscopy based on compressive sensing (CS) by comparing step-index (SI) MMFs with graded-index (GRIN) fibers. Mode-expansion-based simulations are used to assess the accuracy of image reconstruction in the presence of fundamental photon noise and lateral fiber shifts. We show that both fiber types exhibit comparable noise sensitivity, but GRIN fibers are significantly more robust to lateral misalignment errors. These results establish GRIN MMFs as an alignment-tolerant platform for robust computational microendoscopy.

Related

  1. Axion Misalignment Across First-Order Phase Transitions
    Galymzhan Baltabay, Francesco D'Eramo, Ville Vaskonen
    arXivPreprintarXiv licenceFull textCosmologyHigh-energy & particle physicsarXiv
  2. QCD axion misalignment during reheating
    Disha Bandyopadhyay, Debasish Borah, Nayan Das
    arXivPreprintarXiv licenceFull textCosmologyHigh-energy & particle physicsarXiv
  3. Field misalignment effect on the in-plane magnetoresistance in the high-temperature superconductor FeSe/SrTiO3
    Jie Liu, Zihan Cui, Xiaorong Liu +4
    arXivPreprintCC BY 4.0Full textCondensed matterarXiv
  4. HWP-synchronous signal induced by misalignment of the sapphire crystal axis
    Yurika Hoshino, Ryota Takaku, Tomotake Matsumura +9
    arXivPreprintarXiv licenceFull textInstrumentation & methodsApplied physics & instrumentationarXivHAL
  5. Asymptotic AEther Misalignment and Universal-Horizon Mechanics
    Walter Arata, Moustafa Ismail, Stefano Liberati +3
    arXivPreprintarXiv licenceFull textGravitation & general relativityHigh-energy & particle physicsarXiv
BibTeX
@misc{pochechuev2026compressive,
  title = {{Compressive microendoscopy in the presence of noise and misalignment: the translational correlation advantage of graded-index fibers}},
  author = {M. S. Pochechuev and T. I. Rajib and A. Dharmasiri and A. M. Zheltikov},
  howpublished = {arXiv},
  year = {2026},
  month = oct,
  doi = {10.48550/arxiv.2610.33933},
  eprint = {2610.33933},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2610.33933},
}
RIS
TY  - UNPB
TI  - Compressive microendoscopy in the presence of noise and misalignment: the translational correlation advantage of graded-index fibers
AU  - M. S. Pochechuev
AU  - T. I. Rajib
AU  - A. Dharmasiri
AU  - A. M. Zheltikov
PY  - 2026
DA  - 2026/10/24
PB  - arXiv
DO  - 10.48550/arxiv.2610.33933
UR  - https://arxiv.org/abs/2610.33933
AB  - Multimode fibers (MMFs) offer a minimally invasive platform for deep-tissue and multisite in vivo optical sensing. Computational microendoscopy methods extend them into the high-resolution imaging domain, but are quite sensitive to experimental errors. This study investigates the robustness of microendoscopy based on compressive sensing (CS) by comparing step-index (SI) MMFs with graded-index (GRIN) fibers. Mode-expansion-based simulations are used to assess the accuracy of image reconstruction in the presence of fundamental photon noise and lateral fiber shifts. We show that both fiber types exhibit comparable noise sensitivity, but GRIN fibers are significantly more robust to lateral misalignment errors. These results establish GRIN MMFs as an alignment-tolerant platform for robust computational microendoscopy.
ER  -