FHIRTrustBench: An Open Benchmark for Evaluating FHIR-Integrated Clinical AI
- 1St. John's University
Abstract
Hospitals now use AI models to support clinical decisions. Increasingly, these models read patient data from electronic health records through FHIR, the standard format for exchanging health data. Before the data reach the model, they are converted: codes are mapped, units are normalised and records become model inputs. This conversion is rebuilt at every hospital, and when it fails, for example when a lab value arrives in an unexpected unit, the model still accepts the input and returns a score, and the error can pass unnoticed. Existing reporting guidelines ask authors to describe how input data were prepared and checked, but not in terms specific enough to verify a FHIR pipeline. Here we introduce FHIRTrustBench, an open benchmark that assesses what published FHIR-based AI systems demonstrate, from patient record to clinician. It defines 46 criteria in five dimensions, each grounded in published work. One dimension, FHIR specificity, also serves as a provisional gate: a proposed reporting threshold that combines two mandatory items with a minimum score. Two coders independently applied the benchmark to 16 published systems and agreed closely (weighted {kappa} = 0.80). Nearly all stated where their data came from, but none fully described how FHIR data became model inputs, and no deployed system reported monitoring its inputs for change. No system passed the gate. This does not mean the systems are unsafe; it means their published evidence cannot show whether they are safe. Because FHIR already provides tools to check each step, much of this gap can be closed by reporting what was done. We release the benchmark, code and coded evidence for reuse.
Related
- Multimodal Ultrasound and Clinical Data for Pediatric Appendicitis: Evaluating Label-Construction Circularity in the Regensburg Benchmark
- Evaluating Open-Weight Large Language Models for Structured Depression Assessment from Clinical Interviews
- Evaluating the value of robotic versus open pancreaticoduodenectomy: improved clinical outcomes without compromising hospital revenue per admission
- Phase 2/3, Open-label, Randomized, Active-controlled Clinical Trial Evaluating the Safety and Efficacy of Imipenem/Cilastatin/Relebactam in Pediatric Patients From Birth to Less Than 18 Years With Gram-negative Bacterial Infections
- Part 1 of a 2-part, open-label clinical trial evaluating repeated nicotinamide riboside parenteral administration: 3 consecutive days of intramuscular and subcutaneous injections
BibTeX
@misc{hayder2026fhirtrustbench,
title = {{FHIRTrustBench: An Open Benchmark for Evaluating FHIR-Integrated Clinical AI}},
author = {N. S. Hayder and B. Khan and S. A. C. Bukhari},
howpublished = {medRxiv},
year = {2026},
month = jul,
doi = {10.64898/2026.07.08.26357574},
url = {https://www.medrxiv.org/content/10.64898/2026.07.08.26357574v2},
note = {CC BY-NC-ND},
}
RIS
TY - UNPB
TI - FHIRTrustBench: An Open Benchmark for Evaluating FHIR-Integrated Clinical AI
AU - N. S. Hayder
AU - B. Khan
AU - S. A. C. Bukhari
PY - 2026
DA - 2026/07/08
PB - medRxiv
DO - 10.64898/2026.07.08.26357574
UR - https://www.medrxiv.org/content/10.64898/2026.07.08.26357574v2
AB - Hospitals now use AI models to support clinical decisions. Increasingly, these models read patient data from electronic health records through FHIR, the standard format for exchanging health data. Before the data reach the model, they are converted: codes are mapped, units are normalised and records become model inputs. This conversion is rebuilt at every hospital, and when it fails, for example when a lab value arrives in an unexpected unit, the model still accepts the input and returns a score, and the error can pass unnoticed. Existing reporting guidelines ask authors to describe how input data were prepared and checked, but not in terms specific enough to verify a FHIR pipeline. Here we introduce FHIRTrustBench, an open benchmark that assesses what published FHIR-based AI systems demonstrate, from patient record to clinician. It defines 46 criteria in five dimensions, each grounded in published work. One dimension, FHIR specificity, also serves as a provisional gate: a proposed reporting threshold that combines two mandatory items with a minimum score. Two coders independently applied the benchmark to 16 published systems and agreed closely (weighted {kappa} = 0.80). Nearly all stated where their data came from, but none fully described how FHIR data became model inputs, and no deployed system reported monitoring its inputs for change. No system passed the gate. This does not mean the systems are unsafe; it means their published evidence cannot show whether they are safe. Because FHIR already provides tools to check each step, much of this gap can be closed by reporting what was done. We release the benchmark, code and coded evidence for reuse.
ER -