Skip to content
DraconiticResearch
Search Sources API
203,948 studies31 sourcesUpdated 44 min ago
Peer-reviewedCC BY 4.0European Journal of Radiology

SPIO-induced susceptibility effects on quantitative liver MRI: cross-method assessment of R2*, PDFF, T1 mapping, and MRE

Abstract

Objectives: To compare hepatic and splenic transverse relaxivity (R2*) derived from two-dimensional (2D) and three-dimensional (3D) multi-echo gradient-echo (ME-GRE) acquisitions before and after superparamagnetic iron oxide (SPIO) administration and to evaluate the effects of SPIO on proton density fat fraction (PDFF), MR spectroscopy (MRS)-derived PDFF, native T1 mapping, and magnetic resonance elastography (MRE)-derived liver stiffness. Materials and methods: In this retrospective study, 48 adults underwent liver MRI at 3 T before and after SPIO administration. Hepatic and splenic R2* and PDFF were obtained from 2D and 3D ME-GRE acquisitions processed using MRQuantif and LiverLab. MRS-derived PDFF, native variable flip angle T1 mapping, and MRE-derived liver stiffness were assessed before and after SPIO administration. Agreement between methods was evaluated using Pearson correlation coefficients, intraclass correlation coefficients (ICC), and Bland-Altman analysis. Predictors of SPIO-induced changes were assessed using multivariable linear regression. Results: SPIO administration resulted in a marked increase in hepatic R2* (approximately 3.5-fold), exceeding the increase observed in the spleen (approximately 2-fold), consistent with predominant hepatic uptake. Correlation between LiverLab and MRQuantif R2* measurements remained strong; however, inter-method agreement deteriorated at higher R2* values after SPIO administration. ME-GRE-based PDFF measurements remained stable with preserved inter-method agreement. In contrast, MRS-derived PDFF demonstrated reduced reliability after SPIO administration, with apparent increases in fat fraction and weakened correlation with ME-GRE PDFF measurements. Native hepatic T1 values decreased uniformly by approximately 500 ms following SPIO administration. MRE-derived liver stiffness showed no significant change after SPIO administration. Conclusion: Using SPIO as a controlled in vivo susceptibility model, this study provides an integrated evaluation of the susceptibility dependence of commonly used quantitative liver MRI biomarkers. SPIO-induced susceptibility effects substantially increase hepatic R2*, impair the reliability of MRS-based fat quantification, and markedly shorten native variable flip angle T1 measurements, while preserving the relative stability of ME-GRE-based PDFF and MRE-derived liver stiffness. These findings improve understanding of the susceptibility-related performance of quantitative liver MRI techniques and may help inform the interpretation and standardization of iron-sensitive MRI biomarkers.

Related

  1. Quantitative susceptibility mapping (QSM) of the cardiovascular system: challenges and perspectives
    Alberto Aimo, Li Huang, Andrew Tyler +5
    Journal of Cardiovascular Magnetic ResonancePeer-reviewedCC BYFull text11 citedSystems & synthetic biologyHAL
  2. An initial clinical evaluation of quantitative susceptibility mapping for quantitative characterization of intramyocardial hemorrhage
    Andrew Tyler, Matthew Li Kam Wa, Simon Littlewood +6
    Journal of Cardiovascular Magnetic ResonancePeer-reviewedCC BY-NC-ND1 citedSystems & synthetic biologyHAL
  3. Characterization of quantitative susceptibility mapping in the left ventricular myocardium
    Andrew Tyler, Li Huang, Karl Kunze +5
    Journal of Cardiovascular Magnetic ResonancePeer-reviewedCC BY6 citedSystems & synthetic biologyHAL
  4. Quantitative trait loci mapping identifies genetic loci modifying MafAS64F-mediated dysglycemia
    M. Maurer, L. Johnson, D. Lee +3
    bioRxivPreprintAll rights reservedFull textGenetics & genomicsbioRxiv
  5. Human Susceptibility to UVB-Induced Immunosuppression Is Associated with UVB-Induced Activation of the DAMP Pathway in the Skin
    Carlos Alberto Mier-Aguilar, Tyler Downing, Mohammad Asif Sherwani +8
    CellsPeer-reviewedCC BYFull textCell biologyEurope PMC
BibTeX
@article{bassalamah2026spioinduced,
  title = {{SPIO-induced susceptibility effects on quantitative liver MRI: cross-method assessment of R2*, PDFF, T1 mapping, and MRE}},
  author = {Sami a Ba-Ssalamah and Sarah Poetter-Lang and Ahmet y Yitik and Tarik Abd El-Aal and Ahmed Ba-Ssalamah and Stephan Kannengiesser and Yves Gandon and Georg Langs and Nina Bastati and Ulrike Attenberger},
  journal = {European Journal of Radiology},
  year = {2026},
  month = jul,
  doi = {10.1016/j.ejrad.2026.113116},
  url = {https://hal.science/hal-05753238v1},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - SPIO-induced susceptibility effects on quantitative liver MRI: cross-method assessment of R2*, PDFF, T1 mapping, and MRE
AU  - Sami a Ba-Ssalamah
AU  - Sarah Poetter-Lang
AU  - Ahmet y Yitik
AU  - Tarik Abd El-Aal
AU  - Ahmed Ba-Ssalamah
AU  - Stephan Kannengiesser
AU  - Yves Gandon
AU  - Georg Langs
AU  - Nina Bastati
AU  - Ulrike Attenberger
PY  - 2026
DA  - 2026/07/25
JO  - European Journal of Radiology
DO  - 10.1016/j.ejrad.2026.113116
UR  - https://hal.science/hal-05753238v1
AB  - Objectives: To compare hepatic and splenic transverse relaxivity (R2*) derived from two-dimensional (2D) and three-dimensional (3D) multi-echo gradient-echo (ME-GRE) acquisitions before and after superparamagnetic iron oxide (SPIO) administration and to evaluate the effects of SPIO on proton density fat fraction (PDFF), MR spectroscopy (MRS)-derived PDFF, native T1 mapping, and magnetic resonance elastography (MRE)-derived liver stiffness. Materials and methods: In this retrospective study, 48 adults underwent liver MRI at 3 T before and after SPIO administration. Hepatic and splenic R2* and PDFF were obtained from 2D and 3D ME-GRE acquisitions processed using MRQuantif and LiverLab. MRS-derived PDFF, native variable flip angle T1 mapping, and MRE-derived liver stiffness were assessed before and after SPIO administration. Agreement between methods was evaluated using Pearson correlation coefficients, intraclass correlation coefficients (ICC), and Bland-Altman analysis. Predictors of SPIO-induced changes were assessed using multivariable linear regression. Results: SPIO administration resulted in a marked increase in hepatic R2* (approximately 3.5-fold), exceeding the increase observed in the spleen (approximately 2-fold), consistent with predominant hepatic uptake. Correlation between LiverLab and MRQuantif R2* measurements remained strong; however, inter-method agreement deteriorated at higher R2* values after SPIO administration. ME-GRE-based PDFF measurements remained stable with preserved inter-method agreement. In contrast, MRS-derived PDFF demonstrated reduced reliability after SPIO administration, with apparent increases in fat fraction and weakened correlation with ME-GRE PDFF measurements. Native hepatic T1 values decreased uniformly by approximately 500 ms following SPIO administration. MRE-derived liver stiffness showed no significant change after SPIO administration. Conclusion: Using SPIO as a controlled in vivo susceptibility model, this study provides an integrated evaluation of the susceptibility dependence of commonly used quantitative liver MRI biomarkers. SPIO-induced susceptibility effects substantially increase hepatic R2*, impair the reliability of MRS-based fat quantification, and markedly shorten native variable flip angle T1 measurements, while preserving the relative stability of ME-GRE-based PDFF and MRE-derived liver stiffness. These findings improve understanding of the susceptibility-related performance of quantitative liver MRI techniques and may help inform the interpretation and standardization of iron-sensitive MRI biomarkers.
SN  - 0720-048X
ER  -