Skip to content
DraconiticResearch
Search Sources API
184,584 studies31 sourcesUpdated 48 min ago
Peer-reviewedCC BYJournal of applied clinical medical physics

Development and validation of a pregnant phantom with adjustable fetal presentation for region-specific fetal radiation dose assessment during pelvic radiography.

  1. 1School of Medical Sciences, Fujita Health University, Toyoake, Aichi, Japan.
  2. 2Department of Radiological Technology, Faculty of Health Sciences, Tohoku University Graduate School of Medicine, Sendai, Miyagi, Japan.

Abstract

Background

Accurate assessment of fetal radiation dose during diagnostic X-ray examinations remains challenging because commercially available pregnancy phantoms do not adequately reproduce fetal anatomy or permit organ-specific dose measurements.Purpose

The purpose of this study was to develop a pregnant phantom with adjustable fetal presentation and to evaluate its anatomical realism and applicability for fetal dose assessment during pelvic radiography.Methods

The developed phantom comprised an anthropomorphic phantom, a whole-body fetal phantom, acrylic components, and water-filled plastic bags. The fetal phantom was fabricated using three-dimensional printing technology and incorporated bone-equivalent and soft-tissue-equivalent materials. Fetal presentations could be adjusted to cephalic or breech presentations by repositioning the fetal phantom within the abdominal phantom. Computed tomography (CT) images were acquired to measure CT numbers of the fetal brain, thorax, abdomen, pelvic bone, and surrounding water-filled regions. Absorbed doses were measured using real-time dosimeters placed at five locations in the fetal head and three locations in the fetal abdomen. Dose measurements were performed during pelvic radiography and compared with those obtained using a conventional homogeneous pregnancy phantom.Results

The mean CT numbers of the fetal brain, thorax, abdomen, pelvic bone, and water-filled regions were 2.1, -0.8, -0.4, 323.8, and 1.6 HU, respectively. These values were within the expected ranges for soft tissue and bone and were comparable to those of a conventional homogeneous phantom. During pelvic radiography, the mean absorbed doses measured using the adjustable fetal-presentation phantom were 1.34 mGy in the fetal head and 0.07 mGy in the fetal abdomen for the cephalic presentation, and 0.05 mGy and 1.67 mGy, respectively, for the breech presentation. In comparison, the mean absorbed dose measured in the fetal region of the conventional homogeneous phantom was 2.05 mGy. The findings demonstrated substantial differences in regional fetal dose distribution according to fetal presentation. In particular, the fetal head dose in the cephalic presentation was lower than that measured using the conventional phantom. This difference may be partly attributable to attenuation by the fetal skull; however, the comparison should be interpreted with caution given differences in phantom geometry, internal materials, and dosimeter locations between the two phantoms.Conclusion

A novel pregnant phantom with adjustable fetal presentation was successfully developed. The phantom reproduced anatomically relevant structures using realistic bone-equivalent and soft-tissue-equivalent materials and enabled direct dose measurements in specific fetal anatomical regions. Compared with a conventional homogeneous phantom, the developed phantom provided a more detailed assessment of fetal dose distributions and allowed evaluation of the effects of fetal presentation on radiation exposure during pelvic radiography.

Related

  1. Development and internal validation of a nomogram for estimating concurrent superficial vein thrombosis at presentation in patients with lower extremity varicose veins
    Lei Jiao, Zhen Zhou, Hongsheng Yin
    Frontiers in medicinePeer-reviewedCC BYFull textGeneral medicineEurope PMC
  2. Development and validation of an artificial intelligence model for basal cell carcinoma detection and section completeness assessment in Mohs micrographic surgery in an Asian cohort
    Li Yang Loo, Wen-Bin Luo, Isaac Hong-Kei Lam +11
    JAAD internationalPeer-reviewedCC BYFull textGeneral medicineEurope PMC
  3. Toward a National Tuberculosis Lateral-Flow Urine Lipoarabinomannan (LF-LAM) External Quality Assessment Program in Thailand: Feasibility Demonstration Through Panel Development, Validation, and Proficiency Testing, March 2025–April 2026
    Supaporn Suparak, Theerawit Tasaneeyapan, Petai Unpol +15
    Diagnostics (Basel, Switzerland)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
  4. Development and Validation of a New Self-Care Scale: Self-Care Assessment for Employees (SAFE)
    Esra Alataş, Fatih Yığman, Semra Ulusoy Kaymak +2
    Psikiyatride Güncel YaklaşımlarPeer-reviewedCC BY-NC-NDFull textPsychiatry & mental healthDOAJ
  5. Socioeconomic status assessment in Lebanese primary health care centers: development and validation of the SES-PHC scale
    Lina Traboulsi, Hala Sacre, Fatima Wehbi +12
    Scientific ReportsPeer-reviewedCC BYFull textGeneral medicineDOAJ
BibTeX
@article{matsunaga2026development,
  title = {{Development and validation of a pregnant phantom with adjustable fetal presentation for region-specific fetal radiation dose assessment during pelvic radiography.}},
  author = {Yuta Matsunaga and Yumi Kataoka and Koichi Chida and Yasuki Asada},
  journal = {Journal of applied clinical medical physics},
  year = {2026},
  month = oct,
  doi = {10.1002/acm2.70859},
  url = {https://europepmc.org/article/MED/42876054},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Development and validation of a pregnant phantom with adjustable fetal presentation for region-specific fetal radiation dose assessment during pelvic radiography.
AU  - Yuta Matsunaga
AU  - Yumi Kataoka
AU  - Koichi Chida
AU  - Yasuki Asada
PY  - 2026
DA  - 2026/10/01
JO  - Journal of applied clinical medical physics
DO  - 10.1002/acm2.70859
UR  - https://europepmc.org/article/MED/42876054
AB  - Background  Accurate assessment of fetal radiation dose during diagnostic X-ray examinations remains challenging because commercially available pregnancy phantoms do not adequately reproduce fetal anatomy or permit organ-specific dose measurements.Purpose  The purpose of this study was to develop a pregnant phantom with adjustable fetal presentation and to evaluate its anatomical realism and applicability for fetal dose assessment during pelvic radiography.Methods  The developed phantom comprised an anthropomorphic phantom, a whole-body fetal phantom, acrylic components, and water-filled plastic bags. The fetal phantom was fabricated using three-dimensional printing technology and incorporated bone-equivalent and soft-tissue-equivalent materials. Fetal presentations could be adjusted to cephalic or breech presentations by repositioning the fetal phantom within the abdominal phantom. Computed tomography (CT) images were acquired to measure CT numbers of the fetal brain, thorax, abdomen, pelvic bone, and surrounding water-filled regions. Absorbed doses were measured using real-time dosimeters placed at five locations in the fetal head and three locations in the fetal abdomen. Dose measurements were performed during pelvic radiography and compared with those obtained using a conventional homogeneous pregnancy phantom.Results  The mean CT numbers of the fetal brain, thorax, abdomen, pelvic bone, and water-filled regions were 2.1, -0.8, -0.4, 323.8, and 1.6 HU, respectively. These values were within the expected ranges for soft tissue and bone and were comparable to those of a conventional homogeneous phantom. During pelvic radiography, the mean absorbed doses measured using the adjustable fetal-presentation phantom were 1.34 mGy in the fetal head and 0.07 mGy in the fetal abdomen for the cephalic presentation, and 0.05 mGy and 1.67 mGy, respectively, for the breech presentation. In comparison, the mean absorbed dose measured in the fetal region of the conventional homogeneous phantom was 2.05 mGy. The findings demonstrated substantial differences in regional fetal dose distribution according to fetal presentation. In particular, the fetal head dose in the cephalic presentation was lower than that measured using the conventional phantom. This difference may be partly attributable to attenuation by the fetal skull; however, the comparison should be interpreted with caution given differences in phantom geometry, internal materials, and dosimeter locations between the two phantoms.Conclusion  A novel pregnant phantom with adjustable fetal presentation was successfully developed. The phantom reproduced anatomically relevant structures using realistic bone-equivalent and soft-tissue-equivalent materials and enabled direct dose measurements in specific fetal anatomical regions. Compared with a conventional homogeneous phantom, the developed phantom provided a more detailed assessment of fetal dose distributions and allowed evaluation of the effects of fetal presentation on radiation exposure during pelvic radiography.
SN  - 1526-9914
ER  -