Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 21 min ago
Peer-reviewedCC BYJournal of experimental orthopaedics

Histomorphology of the human tendon‐bone interface following failed hamstring anterior cruciate ligament reconstruction: A descriptive study

  1. 1Department of Orthopedic Surgery, Trauma Surgery and Sports Medicine, Cologne Merheim Medical Center Witten/Herdecke University Cologne Germany.
  2. 2Department of Pathology, Klinikum Stuttgart University of Tübingen Stuttgart Germany.

Abstract

Purpose

Successful anterior cruciate ligament (ACL) reconstruction depends on stable tendon-bone integration within the drill tunnel. Although animal studies have provided important insights into graft healing, the biological characteristics of the human tendon-bone interface in clinically failed ACL grafts remain insufficiently defined. The aim of this study was to characterise the histological features of the human tendon-bone interface in failed hamstring ACL grafts using light microscopy, with particular emphasis on Sharpey-like fibres and osteogenesis.Methods

This descriptive cross-sectional histological study represents a secondary analysis of a previously established revision ACL cohort, in which tendon-bone interface specimens were obtained from 43 patients undergoing revision ACL surgery after graft failure. Cylindrical samples were harvested from femoral and tibial drill tunnels at the original graft insertion using hollow reamers. After fixation, decalcification and paraffin embedding, sections were stained with hematoxylin and eosin, Masson-Goldner trichrome and Elastica van Gieson. Light microscopic evaluation focused on the tendon-bone adaptation zone, assessing Sharpey-like fibres, cellular composition, osteogenic activity and vascularisation using a study-specific unvalidated semi-quantitative grading system.Results

Histological analysis revealed heterogeneous tendon-bone interface phenotypes. Among the 40 patients with documented failure mechanisms, 90% of graft failures followed an adequate traumatic event. Good or very good adaptation was observed in 76.0% of femoral and 72.2% of tibial specimens. Quiescent adaptation zones showed regular lamellar bone architecture, evenly distributed osteocytes, absence of significant inflammatory infiltrates and well-organised Sharpey-like fibres. In contrast, activated interfaces demonstrated pronounced Sharpey-like fibre formation, numerous osteoblast-like cells and increased vascularisation. Active osteogenesis was observed alongside dense, perpendicularly oriented Sharpey-like fibres in representative specimens.Conclusion

In this descriptive histological study of failed hamstring ACL grafts, tendon-bone interfaces exhibited heterogeneous adaptation patterns with Sharpey-like fibres and osteogenic activity observed together in representative specimens. These findings suggest that clinical graft failure is not necessarily accompanied by loss of tendon-bone interface organisation.Level of evidence

N/A.

Related

  1. Hyperbaric Oxygen Therapy Improves Early Graft Healing Following ACL Reconstruction with Hamstring Autografts
    C.B.G. Leite, D. Meirelles, L.R. Morimoto +3
    Orthopaedic Journal of Sports MedicinePeer-reviewedCC BYFull textSurgery & anaesthesiaDOAJ
  2. Complete patellar tendon reconstruction using combined quadriceps tendon and hamstring autografts following wide resection of peripatellar undifferentiated pleomorphic sarcoma: a case report
    Van Tho Le, Viet Nhuan Ngo, Hoang Lac Bui +1
    International Journal of Surgery Case ReportsPeer-reviewedCC BY-NC-ND 4.0Full textOncologyPMCEurope PMC
  3. A Comparative Study of Functional Outcomes Following Arthroscopic Anterior Cruciate Ligament Reconstruction Using Hamstring Tendon versus Peroneus Longus Tendon Autograft
    A Manikkumaran, A Manikandan, B Vaishnav Kumar
    Journal of Orthopaedic Case ReportsPeer-reviewedCC BY-NCFull textSurgery & anaesthesiaDOAJEurope PMCPMC
  4. Five-year outcomes after brace-free versus brace-based rehabilitation following isolated anterior cruciate ligament reconstruction with hamstring tendon autograft: long-term follow-up of a randomized controlled trial
    Christian Schoepp, Arthur Praetorius, Janina Tennler +8
    Archives of Orthopaedic and Trauma SurgeryPeer-reviewedCC BY 4.0Full textSurgery & anaesthesiaPMC
  5. Clinical and Sport- and Work-Related Outcomes Following Primary and Revision Arthroscopic Coraco- and Acromioclavicular Reconstruction With Hamstring Autograft Augmentation for Chronic Acromioclavicular Joint Instability.
    Marco-Christopher Rupp, Romed P Vieider, Peter Rab +6
    Orthopaedic journal of sports medicinePeer-reviewedCC BY-NC-NDFull textSurgery & anaesthesiaEurope PMCPMC
BibTeX
@article{siemoneit2026histomorphology,
  title = {{Histomorphology of the human tendon‐bone interface following failed hamstring anterior cruciate ligament reconstruction: A descriptive study}},
  author = {Steffen F Siemoneit and Alexander Bosse and Steffen T Ubl and Thomas R Pfeiffer and Julius M Wehrmann and Maiti Münchgesang and Bertil Bouillon and Daniel Günther},
  journal = {Journal of experimental orthopaedics},
  year = {2026},
  month = oct,
  doi = {10.1002/jeo2.70989},
  url = {https://europepmc.org/article/PMC/PMC13795100},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Histomorphology of the human tendon‐bone interface following failed hamstring anterior cruciate ligament reconstruction: A descriptive study
AU  - Steffen F Siemoneit
AU  - Alexander Bosse
AU  - Steffen T Ubl
AU  - Thomas R Pfeiffer
AU  - Julius M Wehrmann
AU  - Maiti Münchgesang
AU  - Bertil Bouillon
AU  - Daniel Günther
PY  - 2026
DA  - 2026/10/01
JO  - Journal of experimental orthopaedics
DO  - 10.1002/jeo2.70989
UR  - https://europepmc.org/article/PMC/PMC13795100
AB  - Purpose  Successful anterior cruciate ligament (ACL) reconstruction depends on stable tendon-bone integration within the drill tunnel. Although animal studies have provided important insights into graft healing, the biological characteristics of the human tendon-bone interface in clinically failed ACL grafts remain insufficiently defined. The aim of this study was to characterise the histological features of the human tendon-bone interface in failed hamstring ACL grafts using light microscopy, with particular emphasis on Sharpey-like fibres and osteogenesis.Methods  This descriptive cross-sectional histological study represents a secondary analysis of a previously established revision ACL cohort, in which tendon-bone interface specimens were obtained from 43 patients undergoing revision ACL surgery after graft failure. Cylindrical samples were harvested from femoral and tibial drill tunnels at the original graft insertion using hollow reamers. After fixation, decalcification and paraffin embedding, sections were stained with hematoxylin and eosin, Masson-Goldner trichrome and Elastica van Gieson. Light microscopic evaluation focused on the tendon-bone adaptation zone, assessing Sharpey-like fibres, cellular composition, osteogenic activity and vascularisation using a study-specific unvalidated semi-quantitative grading system.Results  Histological analysis revealed heterogeneous tendon-bone interface phenotypes. Among the 40 patients with documented failure mechanisms, 90% of graft failures followed an adequate traumatic event. Good or very good adaptation was observed in 76.0% of femoral and 72.2% of tibial specimens. Quiescent adaptation zones showed regular lamellar bone architecture, evenly distributed osteocytes, absence of significant inflammatory infiltrates and well-organised Sharpey-like fibres. In contrast, activated interfaces demonstrated pronounced Sharpey-like fibre formation, numerous osteoblast-like cells and increased vascularisation. Active osteogenesis was observed alongside dense, perpendicularly oriented Sharpey-like fibres in representative specimens.Conclusion  In this descriptive histological study of failed hamstring ACL grafts, tendon-bone interfaces exhibited heterogeneous adaptation patterns with Sharpey-like fibres and osteogenic activity observed together in representative specimens. These findings suggest that clinical graft failure is not necessarily accompanied by loss of tendon-bone interface organisation.Level of evidence  N/A.
SN  - 2197-1153
ER  -