Skip to content
DraconiticResearch
Search Sources API
186,123 studies31 sourcesUpdated 11 min ago
Peer-reviewedCC BY 4.0Scientific Reports

Novel method for measuring serum free hemoglobin in patients with hemolysis

Abstract

Severe hemolysis results in excess free hemoglobin, which may cause organ damage and complicate perioperative management. Exogenous haptoglobin administration is a potential therapeutic strategy; however, its optimal use requires accurate and reliable measurement of free Hb. A novel latex agglutination immunoturbidimetric assay (LATIA) has been developed for this purpose, but its performance in clinical specimens has not been fully validated. This sub-analysis included 119 stored blood samples from 20 adult patients undergoing cardiovascular surgery. Free hemoglobin concentrations were measured using high-performance liquid chromatography (HPLC), the novel LATIA-based assay, and a conventionally used point-of-care method, with HPLC serving as the reference. Agreement between methods was assessed using Bland–Altman analysis, and perioperative changes in free hemoglobin before and after Haptoglobin administration were evaluated. Free hemoglobin levels measured by the novel assay were comparable to those obtained by HPLC, whereas the conventional method showed significant fixed and proportional biases. The novel assay demonstrated no proportional bias and minimal random error. Furthermore, changes in free hemoglobin levels following Haptoglobin administration measured by the novel assay closely reflected those measured by HPLC. These findings suggest that the novel assay provides comparable free hemoglobin measurements and may support haptoglobin dosing and perioperative management.

Related

  1. Vivaray Hb pro non-invasive hemoglobin device: A prospective diagnostic accuracy study measuring agreement with a calibrated blood cell counter
    Devesh Kumar, Sunita Kapoor, Ambanna Gowda +3
    PLOS OnePeer-reviewedCC BY 4.0Systems & synthetic biologyPhysiologyPLOS
  2. Association of Hemoglobin Level and Diagnostic Delay with Left Atrial Volume Index in Patients with Familial Mediterranean Fever: A Cross-Sectional Observational Study
    Bayram Kızılkaya, Osman Cüre, Hüseyin Durak +2
    Journal of clinical medicinePeer-reviewedCC BYFull textGeneral medicineEurope PMC
  3. A method for measuring neighborhood conditions across the life course using self-reported addresses
    Gerald Hunter, Bonnie Ghosh-Dastidar, Greta Jianjia Cheng +4
    BMC Public HealthPeer-reviewedCC BY 4.0Epidemiology & public healthCrossref
  4. Hemoglobin-to-red blood cell distribution width ratio and in-hospital mortality in patients with non-traumatic subarachnoid hemorrhage: a retrospective cohort study
    Weiming Xu, Wenhui He, Hengheng Zhai +5
    Scientific ReportsPeer-reviewedCC BY-NC-ND 4.0Full textNeurologyCrossref
  5. The relationship between hemoglobin concentration and mortality in patients receiving venovenous extracorporeal membrane oxygenation support: a single-center retrospective cohort study
    Xinyi Luo, Yin Xi, Jinquan Xie +12
    Journal of thoracic diseasePeer-reviewedCC BY-NC-NDFull textGeneral medicineEurope PMC
BibTeX
@article{hokka2026novel,
  title = {{Novel method for measuring serum free hemoglobin in patients with hemolysis}},
  author = {Mai Hokka and Moritoki Egi},
  journal = {Scientific Reports},
  year = {2026},
  month = oct,
  doi = {10.1038/s41598-026-75864-8},
  url = {https://www.nature.com/articles/s41598-026-75864-8},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Novel method for measuring serum free hemoglobin in patients with hemolysis
AU  - Mai Hokka
AU  - Moritoki Egi
PY  - 2026
DA  - 2026/10/13
JO  - Scientific Reports
DO  - 10.1038/s41598-026-75864-8
UR  - https://www.nature.com/articles/s41598-026-75864-8
AB  - Severe hemolysis results in excess free hemoglobin, which may cause organ damage and complicate perioperative management. Exogenous haptoglobin administration is a potential therapeutic strategy; however, its optimal use requires accurate and reliable measurement of free Hb. A novel latex agglutination immunoturbidimetric assay (LATIA) has been developed for this purpose, but its performance in clinical specimens has not been fully validated. This sub-analysis included 119 stored blood samples from 20 adult patients undergoing cardiovascular surgery. Free hemoglobin concentrations were measured using high-performance liquid chromatography (HPLC), the novel LATIA-based assay, and a conventionally used point-of-care method, with HPLC serving as the reference. Agreement between methods was assessed using Bland–Altman analysis, and perioperative changes in free hemoglobin before and after Haptoglobin administration were evaluated. Free hemoglobin levels measured by the novel assay were comparable to those obtained by HPLC, whereas the conventional method showed significant fixed and proportional biases. The novel assay demonstrated no proportional bias and minimal random error. Furthermore, changes in free hemoglobin levels following Haptoglobin administration measured by the novel assay closely reflected those measured by HPLC. These findings suggest that the novel assay provides comparable free hemoglobin measurements and may support haptoglobin dosing and perioperative management.
SN  - 2045-2322
ER  -