Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 25 min ago
Peer-reviewedCC BYBiosensors

Effects of Baseline Correction Strategy on Cervical Raman Spectral Analysis in a Late-Gestation Rat Model.

6 affiliations
  1. 1Department of Bioengineering, Graduate School of Natural and Applied Sciences, Karamanoglu Mehmetbey University, Karaman 70200, Türkiye.
  2. 2Department of Obstetrics and Gynecology, Faculty of Medicine, Cukurova University, Adana 01250, Türkiye.
  3. 3Department of Bioengineering, Faculty of Engineering, Karamanoglu Mehmetbey University, Karaman 70200, Türkiye.
  4. 4Department of Orthopedic Surgery, Harvard Medical School, Harvard University, Boston, MA 02015, USA.
  5. 5Department of Clinical Research, Health Institutes of Türkiye (TÜSEB), Ankara 06270, Türkiye.
  6. 6Department of Biomedical Engineering, Faculty of Engineering, Erciyes University, Kayseri 38039, Türkiye.

Abstract

Fluorescence background is a persistent limitation in quantitative Raman spectroscopy of biological tissue, and it is pronounced in the pregnant cervix, where weak Raman bands sit on a strong and variable baseline. Baseline correction is a routine step, yet its effect on the final result is rarely tested in a controlled way. We examined how the choice of correction strategy affects spectral metrics and the biological difference inferred between two gestational stages. Ex vivo cervical spectra from a rat model at gestational days 15 and 20 were processed with fixed-degree polynomial fitting from the second to seventh degrees, five-point piecewise linear correction, an automated polynomial routine, and asymmetric least squares. Correction quality was assessed by the ratio of Raman-active to -inactive regions and by whether each method preserved the direction of gestational change. The choice of method altered the quantitative output and, for some methods, reversed the inferred direction, because the automated high degree of fit over-suppressed the spectrum and inflated the metric. Moderate-degree polynomial fitting and asymmetric least squares gave the most coherent and biologically consistent results. Baseline correction therefore determines cervical Raman outputs and should be selected and reported transparently.

Related

  1. Simultaneous Denoising and Baseline Correction of Microplate Raman Spectra Using a Dual-Branch U-Net
    Khaled S. R. Atia, Robert Hunter, Hanan Anis
    ACS OmegaPeer-reviewedCC BY-NC-ND 4.0Full textBiophysicsCrossrefPMC
  2. Combination Therapy of Cisplatin and Naturally Induced Exosomes from Treated HeLa Cells: A Novel Drug-Free Strategy for Cervical Cancer Treatment
    Sanaz Aghajani, Nasim Vousooghi, Abbas Hajifathali +2
    Advanced Pharmaceutical BulletinPeer-reviewedCC BY 4.0Full textMolecular biology & gene regulationPMCEurope PMC
  3. Metabolic Remodelling in the Mouse Embryo and Placenta at Mid-Gestation
    Wenjie Wang, Wanyue Lv, Jia Zhang +2
    International Journal of Molecular SciencesPeer-reviewedCC BY 4.0General biochemistryCrossref
  4. Specialty-aware benchmark design, split integrity, and baseline evaluation for Korean medical question answering
    Mi-Ae Yang, Kang-Su Ha
    Scientific ReportsPeer-reviewedCC BY-NC-ND 4.0Full textMolecular biology & gene regulationCrossref
  5. Baseline-Wavelength-Guided Calibration and Raman Spectrum Reconstruction for a Cross-Dispersed Echelle Spectrometer
    jian zhang, Li Xiaotian, Jiri Jirigalantu +4
    Optics ExpressPeer-reviewedLicence not statedBiophysicsCrossref
BibTeX
@article{metin2026effects,
  title = {{Effects of Baseline Correction Strategy on Cervical Raman Spectral Analysis in a Late-Gestation Rat Model.}},
  author = {Hatice Metin and Selim Buyukkurt and Mustafa Unal},
  journal = {Biosensors},
  year = {2026},
  month = oct,
  doi = {10.3390/bios16110603},
  url = {https://europepmc.org/article/MED/43082498},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Effects of Baseline Correction Strategy on Cervical Raman Spectral Analysis in a Late-Gestation Rat Model.
AU  - Hatice Metin
AU  - Selim Buyukkurt
AU  - Mustafa Unal
PY  - 2026
DA  - 2026/10/25
JO  - Biosensors
DO  - 10.3390/bios16110603
UR  - https://europepmc.org/article/MED/43082498
AB  - Fluorescence background is a persistent limitation in quantitative Raman spectroscopy of biological tissue, and it is pronounced in the pregnant cervix, where weak Raman bands sit on a strong and variable baseline. Baseline correction is a routine step, yet its effect on the final result is rarely tested in a controlled way. We examined how the choice of correction strategy affects spectral metrics and the biological difference inferred between two gestational stages. Ex vivo cervical spectra from a rat model at gestational days 15 and 20 were processed with fixed-degree polynomial fitting from the second to seventh degrees, five-point piecewise linear correction, an automated polynomial routine, and asymmetric least squares. Correction quality was assessed by the ratio of Raman-active to -inactive regions and by whether each method preserved the direction of gestational change. The choice of method altered the quantitative output and, for some methods, reversed the inferred direction, because the automated high degree of fit over-suppressed the spectrum and inflated the metric. Moderate-degree polynomial fitting and asymmetric least squares gave the most coherent and biologically consistent results. Baseline correction therefore determines cervical Raman outputs and should be selected and reported transparently.
SN  - 2079-6374
ER  -