Skip to content
DraconiticResearch
Search Sources API
226,742 studies31 sourcesUpdated 50 min ago
Peer-reviewedCC BY-NC 4.0Arthroscopy Techniques

Krackow Stitch Augmentation for Arthroscopic Rotator Cuff Repair: Surgical Technique

  1. 1Hyakutake Orthopaedic Hospital Saga Japan
  2. 2Department of Orthopaedic Surgery Kurume University Medical Center Fukuoka Japan

Abstract

Despite the advances in arthroscopic rotator cuff repair, postoperative structural failure remains a persistent problem. Retear patterns are commonly classified as type 1 failure, which is associated with the poor quality of the torn tendon edge, and type 2 failure, which occurs at the medial suture site owing to stress concentration within the repaired tendon. Consequently, we propose an arthroscopic medial augmentation technique using a suture tape‐based Krackow construct placed medial to the footprint as an adjunct to conventional rotator cuff repair. By obtaining additional fixation in more medial tendon tissue, this technique may reduce dependence on a compromised tendon stump and may also help distribute the load away from the medial suture site. This Technical Note describes the surgical details of this augmentation method that is intended to provide additional tendon reinforcement and load sharing without altering the surgeon's preferred primary repair configuration.

Related

  1. Surgical Technique for Arthroscopic Rotator Cuff Repair With All-Polyester Patch Augmentation.
    Brian Fliegel, Kaley Beall, Manik Dham +1
    Arthroscopy techniquesPeer-reviewedCC BY-NC-NDFull textSurgery & anaesthesiaEurope PMC
  2. Biological Augmentation of Arthroscopic Partial‐Thickness Bursal‐Sided Rotator Cuff Repair Using Minced Autologous Glenohumeral Ligament Tissue Particles
    Hengzhi Liu, Xinji Wang, Huajie Mao +1
    Arthroscopy TechniquesPeer-reviewedCC BY 4.0Full textSurgery & anaesthesiaPMC
  3. Arthroscopic “Triple‐Beam” Biologic Augmentation of Massive Rotator Cuff Tears Using the Combined Long Head of Biceps Transposition and Autologous Palmaris Longus Tendon Bridging
    ChenKe Zhang, ZunHan Liu, MoLong Chen +3
    Arthroscopy techniquesPeer-reviewedCC BY-NC-NDFull textSurgery & anaesthesiaEurope PMCPMC
  4. Diamond‐Unit Crisscross Mattress Suture for Double‐Row Rotator Cuff Repair: An All‐Arthroscopic Technique
    Xiao‐He Wang, Chao Fang, Gang Yu +2
    Arthroscopy TechniquesPeer-reviewedCC BY 4.0Full textSurgery & anaesthesiaPMCEurope PMC
  5. All-Arthroscopic Muscle Advancement Technique for Repair of Massive Posterosuperior Rotator Cuff Tears in the Lateral Decubitus Position.
    Katsumasa Nakazawa, Tomoya Manaka, Yoshihiro Hirakawa +4
    Arthroscopy techniquesPeer-reviewedCC BYFull textSurgery & anaesthesiaEurope PMCPMC
BibTeX
@article{nakamura2026krackow,
  title = {{Krackow Stitch Augmentation for Arthroscopic Rotator Cuff Repair: Surgical Technique}},
  author = {Hidehiro Nakamura and Yasuhiro Mitsui and Ryunosuke Abe and Shuichiro Sakai and Kazuto Higuchi and Toshihiro Yoshida and Masafumi Gotoh},
  journal = {Arthroscopy Techniques},
  year = {2026},
  month = nov,
  doi = {10.1002/atn2.70396},
  url = {https://doi.org/10.1002/atn2.70396},
  note = {CC BY-NC 4.0},
}
RIS
TY  - JOUR
TI  - Krackow Stitch Augmentation for Arthroscopic Rotator Cuff Repair: Surgical Technique
AU  - Hidehiro Nakamura
AU  - Yasuhiro Mitsui
AU  - Ryunosuke Abe
AU  - Shuichiro Sakai
AU  - Kazuto Higuchi
AU  - Toshihiro Yoshida
AU  - Masafumi Gotoh
PY  - 2026
DA  - 2026/11/11
JO  - Arthroscopy Techniques
DO  - 10.1002/atn2.70396
UR  - https://doi.org/10.1002/atn2.70396
AB  - Despite the advances in arthroscopic rotator cuff repair, postoperative structural failure remains a persistent problem. Retear patterns are commonly classified as type 1 failure, which is associated with the poor quality of the torn tendon edge, and type 2 failure, which occurs at the medial suture site owing to stress concentration within the repaired tendon. Consequently, we propose an arthroscopic medial augmentation technique using a suture tape‐based Krackow construct placed medial to the footprint as an adjunct to conventional rotator cuff repair. By obtaining additional fixation in more medial tendon tissue, this technique may reduce dependence on a compromised tendon stump and may also help distribute the load away from the medial suture site. This Technical Note describes the surgical details of this augmentation method that is intended to provide additional tendon reinforcement and load sharing without altering the surgeon's preferred primary repair configuration.
SN  - 2212-6287
ER  -