Skip to content
DraconiticResearch
Search Sources API
203,234 studies31 sourcesUpdated 6 min ago
Peer-reviewedCC BY 4.0ACS Omega

Comparative Feasibility Assessment of a Simplified Mossel EE–MacConkey Workflow for Detection of Enterobacteriaceae in Selected Non-Sterile Pharmaceutical Products

  1. 1Evangelical University of Goiás , , ,

Abstract

Microbiological quality control of nonsterile pharmaceutical products requires reliable detection of Enterobacteriaceae while maintaining operational feasibility in routine laboratory settings. Harmonized pharmacopoeial methods involve sequential procedures, including pre-enrichment, selective enrichment, and differential isolation. These steps increase analytical time and resource requirements. In this study, a simplified culture-based workflow consisting of pre-enrichment in Tryptic Soy Broth, selective enrichment in Mossel Enterobacteria Enrichment broth, and isolation on MacConkey agar was comparatively evaluated against harmonized pharmacopoeial procedures. The assessment was performed using Escherichia coli (ATCC 8739) and Salmonella typhimurium (ATCC 14028) inoculated into finished pharmaceutical products (pravastatin sodium and erlotinib tablets) and a raw material (paracetamol). Qualitative recovery of target microorganisms was observed in the evaluated finished products under both workflows. Comparable qualitative recovery patterns were observed under the experimental conditions evaluated. The simplified approach reduced total analysis time from six to 4 days and decreased estimated culture media costs from USD 340.25 to USD 95.99 per analysis. No recovery of E. coli was observed in paracetamol samples under either workflow. Neutralization also failed to restore microbial growth, suggesting potential matrix-associated inhibitory effects. Within the defined experimental scope, the proposed approach proved practically applicable to the evaluated matrices. However, the study was limited to two finished pharmaceutical products and one pharmaceutical raw material. Therefore, broader applicability requires further evaluation across a wider range of pharmaceutical matrices.

Related

  1. Unlocking delafloxacin fluorescence with 9-fluorenyl methyl chloroformate: A sensitive spectrofluorimetric method for pharmaceutical and plasma analysis with greenness and whiteness assessment
    Hany A. Batakoushy, Galal Magdy, Anmar Anwar Khan +2
    BMC ChemistryPeer-reviewedCC BY-NC-ND 4.0Full textAnalytical chemistryPMC
  2. AI-guided optimization and eco-friendly assessment of in lab stability-indicating HPLC method for empagliflozin and sitagliptin in combined pharmaceutical dosage form
    Ashok H Akabari, Ashim Kumar Sen, Yadav Ragini +3
    Results in ChemistryPeer-reviewedCC BY5 citedAnalytical chemistryOpenAlex
  3. Geometric Reaction Path Alignment for Kinetic Feasibility Assessment
    Nicholas Casetti, Connor W. Coley
    ChemRxivPreprintLicence not statedGeneral chemistryChemRxiv
  4. Comparative effects of cooking methods on arsenic speciation and risk assessment in Eriocheir sinensis
    Mengmeng Chen, Huan Cao, Zijun Wang +3
    Food Science and BiotechnologyPeer-reviewedLicence not statedFull textEnvironmental chemistryPMC
  5. Comparative dielectric and physicochemical assessment of surfactant-free TiO2 and SiO2 nanofluids for high voltage transformer mineral oil
    Meshari S. Alshammari, Ahmed I. Omar, Basma Eltlhawy +2
    Scientific ReportsPeer-reviewedCC BY-NC-ND 4.0Full textMaterials & polymersCrossref
BibTeX
@article{bernardes2026comparative,
  title = {{Comparative Feasibility Assessment of a Simplified Mossel EE–MacConkey Workflow for Detection of Enterobacteriaceae in Selected Non-Sterile Pharmaceutical Products}},
  author = {Ana L. S. Bernardes and Luana A. F. Afiune and Osmar N. Silva and José Luís R. Martins and Antônio S. N. Aguiar and Lucimar P. Rosseto},
  journal = {ACS Omega},
  year = {2026},
  month = oct,
  doi = {10.1021/acsomega.6c02842},
  url = {https://pubs.acs.org/acsodf/article/11/42/64465/5449447/Comparative-Feasibility-Assessment-of-a-Simplified},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Comparative Feasibility Assessment of a Simplified Mossel EE–MacConkey Workflow for Detection of Enterobacteriaceae in Selected Non-Sterile Pharmaceutical Products
AU  - Ana L. S. Bernardes
AU  - Luana A. F. Afiune
AU  - Osmar N. Silva
AU  - José Luís R. Martins
AU  - Antônio S. N. Aguiar
AU  - Lucimar P. Rosseto
PY  - 2026
DA  - 2026/10/13
JO  - ACS Omega
DO  - 10.1021/acsomega.6c02842
UR  - https://pubs.acs.org/acsodf/article/11/42/64465/5449447/Comparative-Feasibility-Assessment-of-a-Simplified
AB  - Microbiological quality control of nonsterile pharmaceutical products requires reliable detection of Enterobacteriaceae while maintaining operational feasibility in routine laboratory settings. Harmonized pharmacopoeial methods involve sequential procedures, including pre-enrichment, selective enrichment, and differential isolation. These steps increase analytical time and resource requirements. In this study, a simplified culture-based workflow consisting of pre-enrichment in Tryptic Soy Broth, selective enrichment in Mossel Enterobacteria Enrichment broth, and isolation on MacConkey agar was comparatively evaluated against harmonized pharmacopoeial procedures. The assessment was performed using Escherichia coli (ATCC 8739) and Salmonella typhimurium (ATCC 14028) inoculated into finished pharmaceutical products (pravastatin sodium and erlotinib tablets) and a raw material (paracetamol). Qualitative recovery of target microorganisms was observed in the evaluated finished products under both workflows. Comparable qualitative recovery patterns were observed under the experimental conditions evaluated. The simplified approach reduced total analysis time from six to 4 days and decreased estimated culture media costs from USD 340.25 to USD 95.99 per analysis. No recovery of E. coli was observed in paracetamol samples under either workflow. Neutralization also failed to restore microbial growth, suggesting potential matrix-associated inhibitory effects. Within the defined experimental scope, the proposed approach proved practically applicable to the evaluated matrices. However, the study was limited to two finished pharmaceutical products and one pharmaceutical raw material. Therefore, broader applicability requires further evaluation across a wider range of pharmaceutical matrices.
SN  - 2470-1343
ER  -