Peri-procedural immune blood cell count changes and pacemaker implantation after transcatheter aortic valve implantation: an exploratory study
4 affiliations
- 1University Clinical Hospital, Poznan, Poland
- 2Department of Cardiac Surgery and Transplantology, Poznan University of Medical Sciences, Poznan, Poland
- 3Students Research Group, Poznan University of Medical Sciences, Poznan, Poland
- 4First Department of Cardiology, Poznan University of Medical Sciences, Poznan, Poland
Abstract
Introduction: Transcatheter aortic valve implantation (TAVI) is a minimally invasive treatment for aortic stenosis. Although significant advancements in the TAVI technique have been made, the risk of requiring a permanent pacemaker remains clinically relevant.
Aim: The aim of the study was to analyze the relationship between peri-procedural blood count parameters and the risk of pacemaker implantation after TAVI.
Material and methods: The retrospective study analyzed 115 patients (median (Q1–Q3) age of 76.7 (73.5–81.9) years). Demographic and clinical data were collected. The counts of leukocytes, neutrophils, lymphocytes, monocytes, and platelets were assessed before the procedure, on the day of the procedure (8 hours after the procedure), 24, 48, and 72 hours after the procedure, and at hospital discharge. Pre-procedural and post-procedural heart rhythm disturbances have been recorded.
Results: The analysis showed a predominant increase in neutrophil and monocyte counts after the procedure, without differences between subgroups. Moreover, a decrease in lymphocyte counts was observed after TAVI; however, it was less pronounced in patients who required pacemaker implantation. Patients without heart rhythm disturbances experienced a greater decrease in their lymphocyte count. In the multivariable analysis, an increase in lymphocyte count after the procedure was an independent factor for pacemaker implantation (OR = 5.2, 95% CI: 1.6–16.3, p = 0.005).
Conclusions: After TAVI, increases in neutrophil and monocyte counts and decreases in lymphocyte counts are observed; however, the lymphocyte count decrease is less pronounced in patients with heart rhythm disturbances requiring pacemaker implantation. An increase in lymphocyte count after the procedure was independently associated with pacemaker implantation.
Related
- Feasibility and procedural considerations of a helix-fixation leadless pacemaker implantation in patients with left ventricular assist devices.
- Pre-procedural PALBI and antiarrhythmic drug use for risk stratification of permanent pacemaker implantation after TAVI
- One Catheter, Two Chambers: Feasibility and Acute Procedural Outcomes of Dual-Chamber Leadless Pacemaker Implantation with a Single Delivery Catheter
- Prognostic value of pre- and post-procedural TAPSE/PASP ratio for long-term mortality in patients with left ventricular ejection fraction < 50% undergoing transcatheter aortic valve implantation
- Association Between Changes in Paravalvular Leakage After Transcatheter Aortic Valve Implantation and Serum Lactate Dehydrogenase.
BibTeX
@article{koziarska2026periprocedural,
title = {{Peri-procedural immune blood cell count changes and pacemaker implantation after transcatheter aortic valve implantation: an exploratory study}},
author = {Kinga Koziarska and Anna Olasińska-Wiśniewska and Tomasz Urbanowicz and Karol Stachowiak and Jan Kaczmarek and Anna Witkowska and Bartłomiej Perek and Marek Grygier and Przemysław Mitkowski and Marek Jemielity},
journal = {Kardiochirurgia i Torakochirurgia Polska = Polish Journal of Cardio-Thoracic Surgery},
year = {2026},
month = sep,
doi = {10.5114/kitp.2026.163428},
url = {https://doi.org/10.5114/kitp.2026.163428},
note = {CC BY-NC-SA 4.0},
}
RIS
TY - JOUR
TI - Peri-procedural immune blood cell count changes and pacemaker implantation after transcatheter aortic valve implantation: an exploratory study
AU - Kinga Koziarska
AU - Anna Olasińska-Wiśniewska
AU - Tomasz Urbanowicz
AU - Karol Stachowiak
AU - Jan Kaczmarek
AU - Anna Witkowska
AU - Bartłomiej Perek
AU - Marek Grygier
AU - Przemysław Mitkowski
AU - Marek Jemielity
PY - 2026
DA - 2026/09/30
JO - Kardiochirurgia i Torakochirurgia Polska = Polish Journal of Cardio-Thoracic Surgery
DO - 10.5114/kitp.2026.163428
UR - https://doi.org/10.5114/kitp.2026.163428
AB - Introduction: Transcatheter aortic valve implantation (TAVI) is a minimally invasive treatment for aortic stenosis. Although significant advancements in the TAVI technique have been made, the risk of requiring a permanent pacemaker remains clinically relevant. Aim: The aim of the study was to analyze the relationship between peri-procedural blood count parameters and the risk of pacemaker implantation after TAVI. Material and methods: The retrospective study analyzed 115 patients (median (Q1–Q3) age of 76.7 (73.5–81.9) years). Demographic and clinical data were collected. The counts of leukocytes, neutrophils, lymphocytes, monocytes, and platelets were assessed before the procedure, on the day of the procedure (8 hours after the procedure), 24, 48, and 72 hours after the procedure, and at hospital discharge. Pre-procedural and post-procedural heart rhythm disturbances have been recorded. Results: The analysis showed a predominant increase in neutrophil and monocyte counts after the procedure, without differences between subgroups. Moreover, a decrease in lymphocyte counts was observed after TAVI; however, it was less pronounced in patients who required pacemaker implantation. Patients without heart rhythm disturbances experienced a greater decrease in their lymphocyte count. In the multivariable analysis, an increase in lymphocyte count after the procedure was an independent factor for pacemaker implantation (OR = 5.2, 95% CI: 1.6–16.3, p = 0.005). Conclusions: After TAVI, increases in neutrophil and monocyte counts and decreases in lymphocyte counts are observed; however, the lymphocyte count decrease is less pronounced in patients with heart rhythm disturbances requiring pacemaker implantation. An increase in lymphocyte count after the procedure was independently associated with pacemaker implantation.
SN - 1731-5530
SN - 1897-4252
ER -