Dose-Range-Dependent Voxel-Based Biological Dose Conversion From Thoracic Ultra-Hypofractionation to Conventional Fractionation: A Pilot Evaluation and Framework for Future Multicenter Studies.
4 affiliations
- 1Research and Development Department, Healthy Innovations, Rachiine, LBN.
- 2Medical Imaging Department, Holy Family University, Batroun, LBN.
- 3Radiation Oncology Department, Tripoli Governmental Hospital and Doctors Center, Tripoli, LBN.
- 4Radiation Oncology Department, American University of Beirut Medical Center, Beirut, LBN.
Abstract
The growing use of hypofractionated radiotherapy and reirradiation has increased the need for voxel-based conversion of hypofractionated dose distributions to conventional-fractionation equivalents for organ-at-risk (OAR) dose-constraint evaluation. Some voxel-based approaches apply a uniform equivalent dose in 2 Gy fractions (EQD2) to all voxels, which may not fully reproduce the dose characteristics of conventional fractionated radiotherapy, where dose per fraction decreases below 2 Gy with increasing distance from the target. Moreover, use of voxel-based conversion approaches requires validation against established OAR dose constraints. Twelve thoracic ultra-hypofractionated treatment plans prescribed in five fractions were converted using To2GyConstraints version 1.0 (Healthy Innovations, Rachiine, Zgharta, Lebanon; www.healthy-innovations.com), a cloud-based software tool that performs dose-range-dependent voxel-based biological dose conversion from hypofractionated to conventional fractionation. It applies dose-range-dependent models: linear-quadratic-linear (LQ-L)-based EQD2 for high-dose voxels, linear-quadratic (LQ)-based EQD2 for intermediate-dose voxels, and equivalent dose in x Gy fractions (EQDx) for low-dose voxels. Original and converted dose distributions were evaluated using corresponding OAR constraints for their respective fractionation regimens. Constraint-violation status was compared using the original ultra-hypofractionated assessment as the reference. An updated standardized data-collection template incorporating thoracic OAR constraints was developed for future multicenter evaluation. The pilot evaluation demonstrated feasibility and showed promising agreement in OAR constraint-violation assessment between original and converted dose distributions. The standardized workflow provides a framework for multicenter evaluation. Dose-range-dependent voxel-based biological dose conversion using To2GyConstraints is feasible for thoracic ultra-hypofractionated radiotherapy. By accounting for radiobiological behavior across different dose ranges, this approach may improve the representation of conventional-fractionation equivalents for OAR assessment. Larger multicenter evaluation is warranted.
Related
- The future is not always uniform: rethinking radiotherapy through spatial fractionation
- Fractionation as a Tool to Control Mn/Al Site Mixing and Magnetism in CaMn_{2+x}Al_{10-x}
- Sulfur fractionation in coronal plumes as observed by Solar Orbiter/Spectral Imaging of the Coronal Environment
- First ionization potential fractionation of sulfur observed with spectral imaging of the coronal environment
- Thallium isotopic fractionation during adsorption onto natural manganese oxides: a comparison with synthesized analogs
BibTeX
@article{moussallem2026doserangedependent,
title = {{Dose-Range-Dependent Voxel-Based Biological Dose Conversion From Thoracic Ultra-Hypofractionation to Conventional Fractionation: A Pilot Evaluation and Framework for Future Multicenter Studies.}},
author = {Mazen Moussallem and Wassim Jalbout and Dima Mahmoud and Bassem Youssef and Zeinab Reda and Maroun Al Beainy and Antoine Nassif},
journal = {Cureus},
year = {2026},
month = oct,
doi = {10.7759/cureus.118239},
url = {https://europepmc.org/article/MED/43061562},
note = {CC BY},
}
RIS
TY - JOUR
TI - Dose-Range-Dependent Voxel-Based Biological Dose Conversion From Thoracic Ultra-Hypofractionation to Conventional Fractionation: A Pilot Evaluation and Framework for Future Multicenter Studies.
AU - Mazen Moussallem
AU - Wassim Jalbout
AU - Dima Mahmoud
AU - Bassem Youssef
AU - Zeinab Reda
AU - Maroun Al Beainy
AU - Antoine Nassif
PY - 2026
DA - 2026/10/20
JO - Cureus
DO - 10.7759/cureus.118239
UR - https://europepmc.org/article/MED/43061562
AB - The growing use of hypofractionated radiotherapy and reirradiation has increased the need for voxel-based conversion of hypofractionated dose distributions to conventional-fractionation equivalents for organ-at-risk (OAR) dose-constraint evaluation. Some voxel-based approaches apply a uniform equivalent dose in 2 Gy fractions (EQD2) to all voxels, which may not fully reproduce the dose characteristics of conventional fractionated radiotherapy, where dose per fraction decreases below 2 Gy with increasing distance from the target. Moreover, use of voxel-based conversion approaches requires validation against established OAR dose constraints. Twelve thoracic ultra-hypofractionated treatment plans prescribed in five fractions were converted using To2GyConstraints version 1.0 (Healthy Innovations, Rachiine, Zgharta, Lebanon; www.healthy-innovations.com), a cloud-based software tool that performs dose-range-dependent voxel-based biological dose conversion from hypofractionated to conventional fractionation. It applies dose-range-dependent models: linear-quadratic-linear (LQ-L)-based EQD2 for high-dose voxels, linear-quadratic (LQ)-based EQD2 for intermediate-dose voxels, and equivalent dose in x Gy fractions (EQDx) for low-dose voxels. Original and converted dose distributions were evaluated using corresponding OAR constraints for their respective fractionation regimens. Constraint-violation status was compared using the original ultra-hypofractionated assessment as the reference. An updated standardized data-collection template incorporating thoracic OAR constraints was developed for future multicenter evaluation. The pilot evaluation demonstrated feasibility and showed promising agreement in OAR constraint-violation assessment between original and converted dose distributions. The standardized workflow provides a framework for multicenter evaluation. Dose-range-dependent voxel-based biological dose conversion using To2GyConstraints is feasible for thoracic ultra-hypofractionated radiotherapy. By accounting for radiobiological behavior across different dose ranges, this approach may improve the representation of conventional-fractionation equivalents for OAR assessment. Larger multicenter evaluation is warranted.
SN - 2168-8184
ER -