Dose-Range-Dependent Voxel-Based Biological Dose Conversion From Thoracic Ultra-Hypofractionation to Conventional Fractionation: A Pilot Evaluation and Framework for Future Multicenter Studies.

4 affiliations
  1. 1Research and Development Department, Healthy Innovations, Rachiine, LBN.
  2. 2Medical Imaging Department, Holy Family University, Batroun, LBN.
  3. 3Radiation Oncology Department, Tripoli Governmental Hospital and Doctors Center, Tripoli, LBN.
  4. 4Radiation Oncology Department, American University of Beirut Medical Center, Beirut, LBN.

Abstract

The growing use of hypofractionated radiotherapy and reirradiation has increased the need for voxel-based conversion of hypofractionated dose distributions to conventional-fractionation equivalents for organ-at-risk (OAR) dose-constraint evaluation. Some voxel-based approaches apply a uniform equivalent dose in 2 Gy fractions (EQD2) to all voxels, which may not fully reproduce the dose characteristics of conventional fractionated radiotherapy, where dose per fraction decreases below 2 Gy with increasing distance from the target. Moreover, use of voxel-based conversion approaches requires validation against established OAR dose constraints. Twelve thoracic ultra-hypofractionated treatment plans prescribed in five fractions were converted using To2GyConstraints version 1.0 (Healthy Innovations, Rachiine, Zgharta, Lebanon; www.healthy-innovations.com), a cloud-based software tool that performs dose-range-dependent voxel-based biological dose conversion from hypofractionated to conventional fractionation. It applies dose-range-dependent models: linear-quadratic-linear (LQ-L)-based EQD2 for high-dose voxels, linear-quadratic (LQ)-based EQD2 for intermediate-dose voxels, and equivalent dose in x Gy fractions (EQDx) for low-dose voxels. Original and converted dose distributions were evaluated using corresponding OAR constraints for their respective fractionation regimens. Constraint-violation status was compared using the original ultra-hypofractionated assessment as the reference. An updated standardized data-collection template incorporating thoracic OAR constraints was developed for future multicenter evaluation. The pilot evaluation demonstrated feasibility and showed promising agreement in OAR constraint-violation assessment between original and converted dose distributions. The standardized workflow provides a framework for multicenter evaluation. Dose-range-dependent voxel-based biological dose conversion using To2GyConstraints is feasible for thoracic ultra-hypofractionated radiotherapy. By accounting for radiobiological behavior across different dose ranges, this approach may improve the representation of conventional-fractionation equivalents for OAR assessment. Larger multicenter evaluation is warranted.

Related

  1. The future is not always uniform: rethinking radiotherapy through spatial fractionation
    Federico Iori, Slavisa Tubin, Waleed Fouad Mourad +24
    Nature Reviews Clinical OncologyPeer-reviewedLicence not stated9 citedApplied physics & instrumentationOpenAlex
  2. Fractionation as a Tool to Control Mn/Al Site Mixing and Magnetism in CaMn_{2+x}Al_{10-x}
    Szymon Królak, Sushma Kumari, Sergey L. Bud'ko +1
    arXivPreprintarXiv licenceFull textCondensed matterarXiv
  3. Sulfur fractionation in coronal plumes as observed by Solar Orbiter/Spectral Imaging of the Coronal Environment
    Slimane Mzerguat, Miho Janvier, Eric Buchlin +4
    Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering SciencesPeer-reviewedCC BY 4.0Full text4 citedSolar & stellar physicsGeneral physicsHAL
  4. First ionization potential fractionation of sulfur observed with spectral imaging of the coronal environment
    Natalia Zambrana Prado, Therese Kucera, Eric Buchlin +3
    Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering SciencesPeer-reviewedCC BY 4.0Full text1 citedSolar & stellar physicsGeneral physicsHAL
  5. Thallium isotopic fractionation during adsorption onto natural manganese oxides: a comparison with synthesized analogs
    Yi Wang, Gabriela A Farfan, Jeffrey E Post +3
    Geochimica et Cosmochimica ActaPeer-reviewedCC BY-NC-ND 4.0Full text3 citedInorganic & organometallic chemistryPhysical chemistryHAL
BibTeX
@article{moussallem2026doserangedependent,
  title = {{Dose-Range-Dependent Voxel-Based Biological Dose Conversion From Thoracic Ultra-Hypofractionation to Conventional Fractionation: A Pilot Evaluation and Framework for Future Multicenter Studies.}},
  author = {Mazen Moussallem and Wassim Jalbout and Dima Mahmoud and Bassem Youssef and Zeinab Reda and Maroun Al Beainy and Antoine Nassif},
  journal = {Cureus},
  year = {2026},
  month = oct,
  doi = {10.7759/cureus.118239},
  url = {https://europepmc.org/article/MED/43061562},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Dose-Range-Dependent Voxel-Based Biological Dose Conversion From Thoracic Ultra-Hypofractionation to Conventional Fractionation: A Pilot Evaluation and Framework for Future Multicenter Studies.
AU  - Mazen Moussallem
AU  - Wassim Jalbout
AU  - Dima Mahmoud
AU  - Bassem Youssef
AU  - Zeinab Reda
AU  - Maroun Al Beainy
AU  - Antoine Nassif
PY  - 2026
DA  - 2026/10/20
JO  - Cureus
DO  - 10.7759/cureus.118239
UR  - https://europepmc.org/article/MED/43061562
AB  - The growing use of hypofractionated radiotherapy and reirradiation has increased the need for voxel-based conversion of hypofractionated dose distributions to conventional-fractionation equivalents for organ-at-risk (OAR) dose-constraint evaluation. Some voxel-based approaches apply a uniform equivalent dose in 2 Gy fractions (EQD2) to all voxels, which may not fully reproduce the dose characteristics of conventional fractionated radiotherapy, where dose per fraction decreases below 2 Gy with increasing distance from the target. Moreover, use of voxel-based conversion approaches requires validation against established OAR dose constraints. Twelve thoracic ultra-hypofractionated treatment plans prescribed in five fractions were converted using To2GyConstraints version 1.0 (Healthy Innovations, Rachiine, Zgharta, Lebanon; www.healthy-innovations.com), a cloud-based software tool that performs dose-range-dependent voxel-based biological dose conversion from hypofractionated to conventional fractionation. It applies dose-range-dependent models: linear-quadratic-linear (LQ-L)-based EQD2 for high-dose voxels, linear-quadratic (LQ)-based EQD2 for intermediate-dose voxels, and equivalent dose in x Gy fractions (EQDx) for low-dose voxels. Original and converted dose distributions were evaluated using corresponding OAR constraints for their respective fractionation regimens. Constraint-violation status was compared using the original ultra-hypofractionated assessment as the reference. An updated standardized data-collection template incorporating thoracic OAR constraints was developed for future multicenter evaluation. The pilot evaluation demonstrated feasibility and showed promising agreement in OAR constraint-violation assessment between original and converted dose distributions. The standardized workflow provides a framework for multicenter evaluation. Dose-range-dependent voxel-based biological dose conversion using To2GyConstraints is feasible for thoracic ultra-hypofractionated radiotherapy. By accounting for radiobiological behavior across different dose ranges, this approach may improve the representation of conventional-fractionation equivalents for OAR assessment. Larger multicenter evaluation is warranted.
SN  - 2168-8184
ER  -