Application and Optimization of the GET Electronics System for Double-Sided Silicon Strip Detector Readout
Abstract
Double-sided silicon strip detectors (DSSDs) are widely used for charged-particle detection in nuclear reaction experiments. However, the large number of readout channels associated with DSSDs places stringent demands on front-end electronics and data acquisition systems, particularly in experiments employing large detector arrays. In this work, we investigate the application and optimization of the Generic Electronics for Time Projection Chambers (GET) system for multi-channel DSSD readout. Through optimization of the DC-blocking capacitors on the custom-designed interface board and waveform-based energy extraction algorithms, the readout system achieves an energy resolution of σ = 22 keV for 5.49 MeV alpha particles. Its performance is further validated in a representative nuclear physics experiment employing charged-particle telescopes. The results demonstrate that the GET system provides a versatile and scalable waveform-sampling solution for multi-channel DSSD readout.
Versions
Related
- Omnidirectional Radiation Detector with Perpendicular Dual Silicon Photomultiplier Readout - Directional Sensitivity and Machine Learning Source Positioning
- Development of a high-granularity, high-precision timing readout electronics system for large-area MRPC detectors
- Characterization of the RF Board for microwave SQUID multiplexing readout electronics
- PRIMA prototype spaceflight KID readout electronics laboratory characterization
- Readout electronics for SUBMET
BibTeX
@misc{bian2026application,
title = {{Application and Optimization of the GET Electronics System for Double-Sided Silicon Strip Detector Readout}},
author = {Jiawei Bian and Zaihong Yang and Qite Li and Zeyu Du and Xuan Wang and Ningtao Zhang and Pengjie Li and Zhongtao Shen and Kaijie Zhou and Cheng Wang},
howpublished = {arXiv},
year = {2026},
month = oct,
doi = {10.48550/arxiv.2610.12923},
eprint = {2610.12923},
archivePrefix = {arXiv},
url = {https://arxiv.org/abs/2610.12923},
note = {CC BY-NC-ND 4.0},
}
RIS
TY - UNPB
TI - Application and Optimization of the GET Electronics System for Double-Sided Silicon Strip Detector Readout
AU - Jiawei Bian
AU - Zaihong Yang
AU - Qite Li
AU - Zeyu Du
AU - Xuan Wang
AU - Ningtao Zhang
AU - Pengjie Li
AU - Zhongtao Shen
AU - Kaijie Zhou
AU - Cheng Wang
PY - 2026
DA - 2026/10/09
PB - arXiv
DO - 10.48550/arxiv.2610.12923
UR - https://arxiv.org/abs/2610.12923
AB - Double-sided silicon strip detectors (DSSDs) are widely used for charged-particle detection in nuclear reaction experiments. However, the large number of readout channels associated with DSSDs places stringent demands on front-end electronics and data acquisition systems, particularly in experiments employing large detector arrays. In this work, we investigate the application and optimization of the Generic Electronics for Time Projection Chambers (GET) system for multi-channel DSSD readout. Through optimization of the DC-blocking capacitors on the custom-designed interface board and waveform-based energy extraction algorithms, the readout system achieves an energy resolution of σ = 22 keV for 5.49 MeV alpha particles. Its performance is further validated in a representative nuclear physics experiment employing charged-particle telescopes. The results demonstrate that the GET system provides a versatile and scalable waveform-sampling solution for multi-channel DSSD readout.
ER -