Skip to content
DraconiticResearch
Search Sources API
203,234 studies31 sourcesUpdated 44 min ago
PreprintCC BY 4.0arXiv

Numerical Study of Two-Frequency Heating in ECR Ion Source

Abstract

The two-frequency heating (TFH) method is widely used to improve the performance of electron cyclotron resonance (ECR) ion sources, yet its physical mechanisms remain insufficiently understood. In this work, the TFH regime in the DECRIS-PM ECR ion source is studied numerically using the NAM-ECRIS code. Single-frequency heating at 14.51 GHz (500 W) is compared to two-frequency heating at 14.51 GHz and 13 GHz (450 W + 50 W) at equal total power. It is found that while the global plasma parameters remain largely unchanged, the peak density of highly anisotropic electrons (E > 1 keV, Vperp/Vlong > 10) decreases by ~20% and their distribution broadens radially in the TFH regime. This reduction in electron anisotropy is attributed to the randomizing effect of the lower-frequency wave on electron gyromotion, which suppresses plasma micro-instabilities and leads to improved ion production.

Related

  1. Transverse Numerical Approach Combining Fluid-Structure Interaction and Model Reduction Methods of a Modular Thermal Energy Storage System to Improve the Energy Efficiency of District Heating Networks
    Alexandre Godin, Fabien Salmon, Adeline Perro +5
    SSRN ElsevierPreprintLicence not statedGeneral physicsHAL
  2. greenWTE: Frequency-domain solver for the phonon Wigner Transport Equation with arbitrary heating using Green's functions
    Laurenz Kremeyer, Bradley J. Siwick, Samuel Huberman
    arXivPreprintCC BY 4.0Full textCondensed matterarXiv
  3. On-chip high-repetition-rate passively mode-locked frequency comb source based on a microring composite cavity
    Mengmeng Chai, Ao Wang, Yuxiang Ji +2
    Optics ExpressPeer-reviewedLicence not statedOptics & photonicsCrossref
  4. Controlled numerical generation and reconstruction of off-axis digital holograms with object-specific frequency-domain filtering
    Junsheng Lu, Xiaolong Shi, Jiaqi Sun +2
    PLOS OnePeer-reviewedCC BYFull textOptics & photonicsPLOSEurope PMC
  5. Lossy Lorentz boosts at ultra-relativistic energies: Numerical study and source survey of high-energy physics software
    Christian Bierlich
    arXivPreprintarXiv licenceFull textComputational physicsHigh-energy & particle physicsarXiv
BibTeX
@misc{kidanova2026numerical,
  title = {{Numerical Study of Two-Frequency Heating in ECR Ion Source}},
  author = {E. Yu. Kidanova and V. E. Mironov and D. K. Pugachev},
  howpublished = {arXiv},
  year = {2026},
  month = nov,
  doi = {10.48550/arxiv.2611.02814},
  eprint = {2611.02814},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2611.02814},
  note = {CC BY 4.0},
}
RIS
TY  - UNPB
TI  - Numerical Study of Two-Frequency Heating in ECR Ion Source
AU  - E. Yu. Kidanova
AU  - V. E. Mironov
AU  - D. K. Pugachev
PY  - 2026
DA  - 2026/11/02
PB  - arXiv
DO  - 10.48550/arxiv.2611.02814
UR  - https://arxiv.org/abs/2611.02814
AB  - The two-frequency heating (TFH) method is widely used to improve the performance of electron cyclotron resonance (ECR) ion sources, yet its physical mechanisms remain insufficiently understood. In this work, the TFH regime in the DECRIS-PM ECR ion source is studied numerically using the NAM-ECRIS code. Single-frequency heating at 14.51 GHz (500 W) is compared to two-frequency heating at 14.51 GHz and 13 GHz (450 W + 50 W) at equal total power. It is found that while the global plasma parameters remain largely unchanged, the peak density of highly anisotropic electrons (E > 1 keV, Vperp/Vlong > 10) decreases by ~20% and their distribution broadens radially in the TFH regime. This reduction in electron anisotropy is attributed to the randomizing effect of the lower-frequency wave on electron gyromotion, which suppresses plasma micro-instabilities and leads to improved ion production.
ER  -