Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 24 min ago
Peer-reviewedCC BYBiosensors

Evaluation of Tremor Degree Using Triangulation Estimation for IMU Volumetric Method Based on Robust Mahalanobis Distance for Outlier Detection.

6 affiliations
  1. 1College of Information Science and Engineering, Hohai University, Changzhou 213200, China.
  2. 2Henan International Joint Laboratory of Machine Vision and Intelligent Systems, Department of Information Engineering, Pingdingshan University, Pingdingshan 467000, China.
  3. 3School of Energy and Electrical Engineering, Pingdingshan University, Pingdingshan 467000, China.
  4. 4Pingdingshan First People's Hospital, First Affiliated Hospital of Pingdingshan University, Pingdingshan 467000, China.
  5. 5State Key Lab of Bioelectronics, Southeast University, Nanjing 210096, China.
  6. 6Institute of Radio Frequency and Optoelectronic Integrated Circuits, Southeast University, Nanjing 210096, China.

Abstract

Parkinson's disease (PD) is a rapidly progressive neurodegenerative disorder whose core motor symptoms-tremor, bradykinesia, and rigidity-severely impair patients' quality of life. Conventional clinical rating scales are inherently subjective and exhibit limited inter-rater reliability, underscoring the urgent need for objective and quantitative assessment tools. This article presents a novel proof-of-concept study that lays the foundation for objective tremor quantification based on inertial measurement unit (IMU) signals. The framework consists of three stages: first, a robust Mahalanobis distance algorithm based on the minimum covariance determinant (MCD) estimator eliminates multivariate outliers from raw IMU data; second, acceleration in the sensor coordinate system is converted to the geographic coordinate system via quaternion rotation, the gravitational component is removed, and 3D tremor trajectories are reconstructed using Simpson's numerical integration; third, Delaunay triangulation partitions the reconstructed point cloud, constructs pentahedral voxels, and calculates the enclosed volume, which serves as an intuitive metric for tremor energy and spatial activity range. The method was evaluated using a BWT61CL IMU sensor (sampling frequency 100 Hz) to collect hand tremor data from four PD rest tremor (RT) patients and four matched healthy control (HC) participants under standardized rest conditions. To assess the ability of the method to distinguish pathological tremor from physiological motion, the control group was expanded to include four Essential tremor (ET) patients. This revealed a measurable reduction in tremor volume post-treatment compared to baseline, consistent with the expected direction of clinical observations. These preliminary findings suggest that the proposed IMU-based volume method, combining robust Mahalanobis distance and Delaunay triangulation, has potential for tracking the spatiotemporal evolution of tremor symptoms in PD, offering a proof-of-concept analytical framework for quantifying tremor spatial amplitude that warrants validation in larger cohorts.

Related

  1. High-fat diet and portal hypertension: a triangulation approach combining Mendelian randomization with retrospective clinical analysis
    Yu Xu, Siqi Yang, Yuying Li +2
    Frontiers in gastroenterology (Lausanne, Switzerland)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
  2. Accurate gestational age estimation with a deep learning model using ultrasound images to enhance detection of fetal growth restriction and small-for-gestational-age fetuses in late pregnancy: a prospective cohort study
    Divyanshu Mishra, Radhika Chanian, Rahul Jain +53
    eClinicalMedicinePeer-reviewedCC BY-NC-ND 4.0General medicineCrossref
  3. Estimation and detection of rotor mass imbalance of wind turbines using convolutional neural network
    Yunqiang Yan
    Scientific ReportsPeer-reviewedCC BYFull textGeneral medicineDOAJ
  4. Comparative evaluation of single and multiple camera-based pose estimation methods for gait spatiotemporal parameter estimation
    Bethany Weber, Brandon Schoenwether, Tyler Booth +3
    PLOS OnePeer-reviewedCC BY 4.0Full textSystems & synthetic biologyPhysiologyPLOSPMC
  5. Bladder scanning in children: accuracy of volume estimation and detection of urinary retention
    A. C. de Jong, O. E. Arguedas Flores, J. B. M. van Woensel +4
    medRxivPreprintCC BYFull textObstetrics, gynaecology & paediatricsmedRxiv
BibTeX
@article{lou2026evaluation,
  title = {{Evaluation of Tremor Degree Using Triangulation Estimation for IMU Volumetric Method Based on Robust Mahalanobis Distance for Outlier Detection.}},
  author = {Pengyu Lou and Cheng Xu and Kaiyang Yin and Enhui Guo and Xiaoying Lü and Zhigong Wang},
  journal = {Biosensors},
  year = {2026},
  month = oct,
  doi = {10.3390/bios16110616},
  url = {https://europepmc.org/article/MED/43082511},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Evaluation of Tremor Degree Using Triangulation Estimation for IMU Volumetric Method Based on Robust Mahalanobis Distance for Outlier Detection.
AU  - Pengyu Lou
AU  - Cheng Xu
AU  - Kaiyang Yin
AU  - Enhui Guo
AU  - Xiaoying Lü
AU  - Zhigong Wang
PY  - 2026
DA  - 2026/10/30
JO  - Biosensors
DO  - 10.3390/bios16110616
UR  - https://europepmc.org/article/MED/43082511
AB  - Parkinson's disease (PD) is a rapidly progressive neurodegenerative disorder whose core motor symptoms-tremor, bradykinesia, and rigidity-severely impair patients' quality of life. Conventional clinical rating scales are inherently subjective and exhibit limited inter-rater reliability, underscoring the urgent need for objective and quantitative assessment tools. This article presents a novel proof-of-concept study that lays the foundation for objective tremor quantification based on inertial measurement unit (IMU) signals. The framework consists of three stages: first, a robust Mahalanobis distance algorithm based on the minimum covariance determinant (MCD) estimator eliminates multivariate outliers from raw IMU data; second, acceleration in the sensor coordinate system is converted to the geographic coordinate system via quaternion rotation, the gravitational component is removed, and 3D tremor trajectories are reconstructed using Simpson's numerical integration; third, Delaunay triangulation partitions the reconstructed point cloud, constructs pentahedral voxels, and calculates the enclosed volume, which serves as an intuitive metric for tremor energy and spatial activity range. The method was evaluated using a BWT61CL IMU sensor (sampling frequency 100 Hz) to collect hand tremor data from four PD rest tremor (RT) patients and four matched healthy control (HC) participants under standardized rest conditions. To assess the ability of the method to distinguish pathological tremor from physiological motion, the control group was expanded to include four Essential tremor (ET) patients. This revealed a measurable reduction in tremor volume post-treatment compared to baseline, consistent with the expected direction of clinical observations. These preliminary findings suggest that the proposed IMU-based volume method, combining robust Mahalanobis distance and Delaunay triangulation, has potential for tracking the spatiotemporal evolution of tremor symptoms in PD, offering a proof-of-concept analytical framework for quantifying tremor spatial amplitude that warrants validation in larger cohorts.
SN  - 2079-6374
ER  -