Comparative evaluation of single and multiple camera-based pose estimation methods for gait spatiotemporal parameter estimation
4 affiliations
- 1Department of Kinesiology and Sport Sciences, University of Miami, Coral Gables, Florida, United States of America
- 2Department of Psychology, University of Miami, Coral Gables, Florida, United States of America
- 3Department of Industrial and Systems Engineering, University of Miami, Coral Gables, Florida, United States of America
- 4Department of Physical Therapy, University of Miami Miller School of Medicine, Miami, Florida, United States of America
Abstract
Single-camera pose estimation may provide a more accessible approach to measure a person’s walking patterns (i.e., gait analysis) than multi-camera markerless motion capture (MMC), but its validity and test-retest reliability remain unclear. This study evaluated spatiotemporal gait parameters from a single iPad camera against an eight-camera MMC reference system across four visits, two weeks apart. Thirty-six healthy adults (18.7 ± 1.7, ranging 18‒27 years) completed usual-gait, bag-carrying, and phone-use walking conditions. Validity analyses included 458 paired trials from Visit 1 and used repeated-measures and mixed-effects methods. Reliability analyses included 33 participants with complete four-visit data and evaluated absolute agreement of single visit-level measurements. Using repeated-measures correlation, the strongest within-participant association between systems was gait speed (rrm = 0.588), followed by stance duration (rrm = 0.528), cycle time (rrm = 0.515), and cadence (rrm = 0.446; all p < 0.001). Step length, calculated as half of stride length, and stride length showed weaker associations (rrm = 0.327 and 0.328; both p < 0.001), whereas swing duration was not significantly associated (p = 0.599). Independent step length and left−right step-length asymmetry were not evaluated. Mean system differences were small, but significant proportional bias was present for all seven gait variables, indicating that system differences changed with measurement magnitude. Walking condition influenced bias for cadence, gait speed, cycle time, step length, and stride length. Test-retest reliability varied by parameter and condition, with absolute-agreement intraclass correlation coefficients ranging from 0.499 to 0.862. Gait speed demonstrated good reliability across all three conditions, step and stride length demonstrated their highest reliability during the phone condition, and swing duration consistently demonstrated the lowest reliability. These findings support the feasibility of single-camera MMC for selected spatiotemporal gait outcomes, particularly gait speed, when accessibility and reduced equipment requirements are priorities. However, the approaches should not be considered interchangeable. Multi-camera MMC may remain better suited when three-dimensional reconstruction or more comprehensive spatial and temporal characterization is required.
Related
- Topologically-based parameter inference for agent-based model selection from spatiotemporal cellular data
- Evaluation of spatiotemporal patterns and uncertainty of multi-source remote sensing GPP products in the Southwest karst region of China
- Spatiotemporal stability of DUS characteristics in maize and evaluation of spatial replication testing models
- Surrogate Gradients for Gradient-Based Parameter Estimation in Simplified Neuron Models
- EG-BINN: Parameter-Efficient Ensembling of Gated Biologically Informed Neural Networks for Epigenetic Age Estimation
BibTeX
@article{weber2026comparative,
title = {{Comparative evaluation of single and multiple camera-based pose estimation methods for gait spatiotemporal parameter estimation}},
author = {Bethany Weber and Brandon Schoenwether and Tyler Booth and Megan McFarland and Jennifer Britton and Moataz Eltoukhy},
journal = {PLOS One},
year = {2026},
month = nov,
doi = {10.1371/journal.pone.0363369},
url = {https://doi.org/10.1371/journal.pone.0363369},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - Comparative evaluation of single and multiple camera-based pose estimation methods for gait spatiotemporal parameter estimation
AU - Bethany Weber
AU - Brandon Schoenwether
AU - Tyler Booth
AU - Megan McFarland
AU - Jennifer Britton
AU - Moataz Eltoukhy
PY - 2026
DA - 2026/11/20
JO - PLOS One
DO - 10.1371/journal.pone.0363369
UR - https://doi.org/10.1371/journal.pone.0363369
AB - Single-camera pose estimation may provide a more accessible approach to measure a person’s walking patterns (i.e., gait analysis) than multi-camera markerless motion capture (MMC), but its validity and test-retest reliability remain unclear. This study evaluated spatiotemporal gait parameters from a single iPad camera against an eight-camera MMC reference system across four visits, two weeks apart. Thirty-six healthy adults (18.7 ± 1.7, ranging 18‒27 years) completed usual-gait, bag-carrying, and phone-use walking conditions. Validity analyses included 458 paired trials from Visit 1 and used repeated-measures and mixed-effects methods. Reliability analyses included 33 participants with complete four-visit data and evaluated absolute agreement of single visit-level measurements. Using repeated-measures correlation, the strongest within-participant association between systems was gait speed (rrm = 0.588), followed by stance duration (rrm = 0.528), cycle time (rrm = 0.515), and cadence (rrm = 0.446; all p < 0.001). Step length, calculated as half of stride length, and stride length showed weaker associations (rrm = 0.327 and 0.328; both p < 0.001), whereas swing duration was not significantly associated (p = 0.599). Independent step length and left−right step-length asymmetry were not evaluated. Mean system differences were small, but significant proportional bias was present for all seven gait variables, indicating that system differences changed with measurement magnitude. Walking condition influenced bias for cadence, gait speed, cycle time, step length, and stride length. Test-retest reliability varied by parameter and condition, with absolute-agreement intraclass correlation coefficients ranging from 0.499 to 0.862. Gait speed demonstrated good reliability across all three conditions, step and stride length demonstrated their highest reliability during the phone condition, and swing duration consistently demonstrated the lowest reliability. These findings support the feasibility of single-camera MMC for selected spatiotemporal gait outcomes, particularly gait speed, when accessibility and reduced equipment requirements are priorities. However, the approaches should not be considered interchangeable. Multi-camera MMC may remain better suited when three-dimensional reconstruction or more comprehensive spatial and temporal characterization is required.
SN - 1932-6203
ER -