Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 32 min ago
Peer-reviewedCC BY 4.0Diagnostics

Per-Patient Polyp Detection Rate of Colon Capsule Endoscopy: A Systematic Review and Meta-Analysis with Exploratory Stratification by Referral Pathway

7 affiliations
  1. 1Institute of Precision Diagnostics & Translational Medicine, University Hospitals Coventry and Warwickshire NHS Trust, Coventry CV2 2DX, UK
  2. 2Department of Gastroenterology, Oxford University Hospitals NHS Foundation Trust, Oxford OX3 9DU, UK
  3. 3Department of Digestive Diseases, University Hospitals of Leicester NHS Trust, Leicester LE5 4PW, UK
  4. 4Leicester Cancer Centre, University of Leicester, Leicester LE1 7RH, UK
  5. 5Department of Clinical Research, University of Southern Denmark, 5230 Odense, Denmark
  6. 6Department of Surgery, Odense University Hospital, 5000 Odense, Denmark
  7. 7Department of Gastroenterology, Pomeranian Medical University, 70-204 Szczecin, Poland

Abstract

Background/Objectives: Colon capsule endoscopy (CCE) is a minimally invasive alternative to optical colonoscopy, but per-patient polyp detection rate (PDR), the proportion of patients with at least one visually reported polyp, varies across referral populations. We estimated any-polyp and size-stratified CCE yield and explored between-study variation. Methods: MEDLINE, Embase, PubMed, and Cochrane CENTRAL were searched from 1 January 2004 to 29 July 2026. Proportions were pooled using random-intercept binomial-normal generalised linear mixed models. PROSPERO: CRD420261464937 (registration not prospective). Results: Of 44 retained studies (12,754 participants), 31 independent studies (11,310 participants) formed the primary pool. Pooled PDR was 53.2% (95% CI 46.1–60.1; prediction interval 19–85%), a descriptive average, not a performance target. Exploratory PDR was 81.2% after positive FIT (k = 4), 49.4% after incomplete colonoscopy (k = 4), and 39.9% in screening without prior FIT enrichment (k = 3); 14 studies had mixed pathways. Pooled detection was 32.7% for polyps ≥ 6 mm (prediction interval 8–74%) and 17.7% for polyps ≥ 10 mm (4–51%). Conclusions: CCE PDR is a visual yield measure, not adenoma detection or diagnostic accuracy. A global CCE PDR is not a portable quality threshold; referral-pathway estimates are descriptive and hypothesis-generating. Future quality metrics require standardised pathways, denominators, and linkage to downstream clinical outcomes.

Related

  1. Artificial Intelligence Approaches for Gastrointestinal Bleeding Detection in Capsule Endoscopy: A Systematic Review and Critical Analysis
    Nasima Mohammad Helal, Jon Zaccary Regala, Mujeeb Rahman
    DiagnosticsPeer-reviewedCC BY 4.0Full textGeneral medicinePMC
  2. Concordancia diagnóstica entre la cápsula endoscópica y la enteroscopía de doble balón en la hemorragia digestiva de intestino medio en un hospital de referencia en Perú Diagnostic Agreement Between Capsule Endoscopy and Double-Balloon Enteroscopy in Mid-Gut Gastrointestinal Bleeding at a Referral Hospital in Peru
    Ofelia Castillo-Contreras, Jairo Asencios-Cusihuallpa, Elizabeth Ayala-Quintanilla
    Acta gastroenterologica LatinoamericanaPeer-reviewedCC BY-NC-SAFull textGeneral medicineEurope PMC
  3. Factors associated with hypertension in Nigeria: a systematic review and m​eta-analysis with an exploratory risk stratification framework
    Martins Nweke, Julian D Pillay
    Frontiers in Cardiovascular MedicinePeer-reviewedCC BY 4.0Cardiovascular medicineCrossref
  4. A Two-Tier Patient-Based Real-Time Quality Control Program Integrating K-Means Department Stratification and Inter-Instrument Ratios Improves Detection of Small Systematic Errors in Creatinine Testing.
    Xuemei Wei, Ziqing Jiang, Jingzhu Nan +5
    Diagnostics (Basel, Switzerland)Peer-reviewedCC BYFull textPhysiologyEurope PMC
  5. Multimodal Risk Stratification and Surveillance for Gastric Cancer in Chronic Atrophic Gastritis and Gastric Intestinal Metaplasia: Integrating Histology, Endoscopy, Biomarkers, and Artificial Intelligence
    Shujie Gao, Yiqing Zhao, Huihong Ji +4
    Clinical and Experimental GastroenterologyPeer-reviewedCC BY-NC 4.0Full textGeneral medicinePMC
BibTeX
@article{lei2026perpatient,
  title = {{Per-Patient Polyp Detection Rate of Colon Capsule Endoscopy: A Systematic Review and Meta-Analysis with Exploratory Stratification by Referral Pathway}},
  author = {Ian Io Lei and Grazia Bernui Vigo and Ramesh P. Arasaradnam and Anastasios Koulaouzidis},
  journal = {Diagnostics},
  year = {2026},
  month = oct,
  doi = {10.3390/diagnostics16213493},
  url = {https://doi.org/10.3390/diagnostics16213493},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Per-Patient Polyp Detection Rate of Colon Capsule Endoscopy: A Systematic Review and Meta-Analysis with Exploratory Stratification by Referral Pathway
AU  - Ian Io Lei
AU  - Grazia Bernui Vigo
AU  - Ramesh P. Arasaradnam
AU  - Anastasios Koulaouzidis
PY  - 2026
DA  - 2026/10/25
JO  - Diagnostics
DO  - 10.3390/diagnostics16213493
UR  - https://doi.org/10.3390/diagnostics16213493
AB  - Background/Objectives: Colon capsule endoscopy (CCE) is a minimally invasive alternative to optical colonoscopy, but per-patient polyp detection rate (PDR), the proportion of patients with at least one visually reported polyp, varies across referral populations. We estimated any-polyp and size-stratified CCE yield and explored between-study variation. Methods: MEDLINE, Embase, PubMed, and Cochrane CENTRAL were searched from 1 January 2004 to 29 July 2026. Proportions were pooled using random-intercept binomial-normal generalised linear mixed models. PROSPERO: CRD420261464937 (registration not prospective). Results: Of 44 retained studies (12,754 participants), 31 independent studies (11,310 participants) formed the primary pool. Pooled PDR was 53.2% (95% CI 46.1–60.1; prediction interval 19–85%), a descriptive average, not a performance target. Exploratory PDR was 81.2% after positive FIT (k = 4), 49.4% after incomplete colonoscopy (k = 4), and 39.9% in screening without prior FIT enrichment (k = 3); 14 studies had mixed pathways. Pooled detection was 32.7% for polyps ≥ 6 mm (prediction interval 8–74%) and 17.7% for polyps ≥ 10 mm (4–51%). Conclusions: CCE PDR is a visual yield measure, not adenoma detection or diagnostic accuracy. A global CCE PDR is not a portable quality threshold; referral-pathway estimates are descriptive and hypothesis-generating. Future quality metrics require standardised pathways, denominators, and linkage to downstream clinical outcomes.
SN  - 2075-4418
ER  -