Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 27 min ago
PreprintarXiv licencearXiv

Fewer Fractions, Equieffective Plans: An optimization framework based on equieffective dose

Abstract

Background: Non-standard fractionation requires caution before clinical use, and planners often need to manually modify the prescription and dose constraints for non-linear biological effects. Purpose: To develop an extension within a treatment planning system that enables the generation of hypofractionated plans based on equieffective dose, EQDnref, for an alternative fractionation deliverable in n fractions, such that it is equieffective with the reference fractionation for a specified biological endpoint. Methods: A research build of RayStation v2025 was extended to optimize EQDnref plans. This study used anonymized data from three head and neck patients. CTVp and CTVn were prescribed 70 Gy and 54 Gy in 35 fractions. Targets, spinal cord, and brainstem were robustly optimized for ±3.5% density and ±3.0 mm setup uncertainties. For each patient, hypofractionated plans were created with 34, 32, 30, and 25 fractions. Sensitivity analysis evaluated the impact of α/β uncertainty. Results: All equieffective hypofractionated plans maintained target coverage and met mandatory clinical goals for organs-at-risk (OARs). Compared to standard fractionation, DVH parameters indicated an average ΔEQDnref <0.2 Gy for CTVp and no difference for CTVn. For parallel OARs, the median mean-dose difference between hypofractionation (to 30 fractions) and standard fractionation was generally <1% of the prescribed dose. α/β uncertainty produced the greatest variation in the 25-fraction regimen, with absolute ΔEQDnref up to 0.88 Gy for targets and up to 0.63 Gy for the spinal cord and brainstem. Conclusions: An EQDnref-based framework can generate equieffective hypofractionated plans, making it feasible to reduce fractions without substantially deviating from existing clinical protocols.

Related

  1. Better accuracy with fewer qubits: Single-particle basis set optimization for quantum chemistry on quantum computers
    Subimal Deb, V. S. Prasannaa
    arXivPreprintCC BY 4.0Full text1 citedPhysical chemistryAtomic, molecular & optical physicsarXiv
  2. A Fast and Accurate Source-Mask Optimization Flow Using a Unified Abbe-Hopkins Framework
    Ying Wang, Ming Zeng, Kaiye Liu +3
    Optics ExpressPeer-reviewedLicence not statedOptics & photonicsCrossref
  3. Efficient SPAD reconstruction framework with time-frequency domain compression and lightweight joint depth-intensity optimization
    Yaoqi Bao, Sijie Wu, Dong Li +4
    Optics ExpressPeer-reviewedPublisher termsApplied physics & instrumentationCrossref
  4. SVD-guided hybrid optimization framework for ab initio aspheric optical design
    Tuo Sun, Wenguan Zhang, Xiangang Gao +8
    Optics ExpressPeer-reviewedPublisher termsOptics & photonicsCrossref
  5. Resolution enhancement framework in surface plasmon imaging lithography based on particle swarm optimization
    pengyu ren, Huwen Ding, Yajuan Su +7
    Optics ExpressPeer-reviewedLicence not statedOptics & photonicsCrossref
BibTeX
@misc{kaushik2026fewer,
  title = {{Fewer Fractions, Equieffective Plans: An optimization framework based on equieffective dose}},
  author = {Suryakant Kaushik and Jakob Ödén and Albin Fredriksson and Iuliana Toma-Dasu},
  howpublished = {arXiv},
  year = {2026},
  month = nov,
  doi = {10.48550/arxiv.2611.34605},
  eprint = {2611.34605},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2611.34605},
}
RIS
TY  - UNPB
TI  - Fewer Fractions, Equieffective Plans: An optimization framework based on equieffective dose
AU  - Suryakant Kaushik
AU  - Jakob Ödén
AU  - Albin Fredriksson
AU  - Iuliana Toma-Dasu
PY  - 2026
DA  - 2026/11/25
PB  - arXiv
DO  - 10.48550/arxiv.2611.34605
UR  - https://arxiv.org/abs/2611.34605
AB  - Background: Non-standard fractionation requires caution before clinical use, and planners often need to manually modify the prescription and dose constraints for non-linear biological effects. Purpose: To develop an extension within a treatment planning system that enables the generation of hypofractionated plans based on equieffective dose, EQD_n_ref, for an alternative fractionation deliverable in n fractions, such that it is equieffective with the reference fractionation for a specified biological endpoint. Methods: A research build of RayStation v2025 was extended to optimize EQD_n_ref plans. This study used anonymized data from three head and neck patients. CTV_p and CTV_n were prescribed 70 Gy and 54 Gy in 35 fractions. Targets, spinal cord, and brainstem were robustly optimized for ±3.5% density and ±3.0 mm setup uncertainties. For each patient, hypofractionated plans were created with 34, 32, 30, and 25 fractions. Sensitivity analysis evaluated the impact of α/β uncertainty. Results: All equieffective hypofractionated plans maintained target coverage and met mandatory clinical goals for organs-at-risk (OARs). Compared to standard fractionation, DVH parameters indicated an average ΔEQD_n_ref <0.2 Gy for CTV_p and no difference for CTV_n. For parallel OARs, the median mean-dose difference between hypofractionation (to 30 fractions) and standard fractionation was generally <1% of the prescribed dose. α/β uncertainty produced the greatest variation in the 25-fraction regimen, with absolute ΔEQD_n_ref up to 0.88 Gy for targets and up to 0.63 Gy for the spinal cord and brainstem. Conclusions: An EQD_n_ref-based framework can generate equieffective hypofractionated plans, making it feasible to reduce fractions without substantially deviating from existing clinical protocols.
ER  -