Endotracheal and Nasogastric Tube-Related Pressure Injuries in Critically Ill Adults: A Prospective Descriptive Cohort Study.
6 affiliations
- 1Critical Care and Emergency Department, Faculty of Nursing, Damanhour University, Damanhour 22511, Egypt.
- 2Department of Nursing, Mohammed Al-Mana College for Medical Sciences, Dammam 34222, Saudi Arabia.
- 3Critical Care and Emergency Nursing Department, Faculty of Nursing, Alexandria University, Alexandria 21527, Egypt.
- 4Medical and Surgical Nursing Department, College of Nursing, Princess Nourah bint Abdulrahman University, P.O. Box 84428, Riyadh 11671, Saudi Arabia .
- 5College of Applied Medical Sciences, King Faisal University, 400, Alhofuf 36362, Saudi Arabia.
- 6Critical Care and Emergency Nursing Department, Faculty of Nursing, Beni-Suef University, Beni-Suef 62511, Egypt.
Abstract
Background/Objectives: Medical device-related pressure injuries (MDRPIs) are a concern in intensive care nursing, and device-specific evidence from Egypt remains limited. This study aimed to describe the occurrence, stages, and time to first detection of endotracheal tube (ETT)- and nasogastric tube (NGT)-related pressure injuries among critically ill adults. Methods: A prospective observational cohort included 210 adults requiring both devices in three intensive care units (ICUs) at an Egyptian university hospital. One researcher conducted admission screening and subsequent skin assessments every 12 h for up to 30 days; suspected injuries were confirmed by ICU surveillance nurses. Findings were summarized descriptively. Results: ETT-related injuries occurred in 194/210 patients (92.4%), and NGT-related injuries occurred in 182/210 patients (86.7%). All participants received both devices, and the device-specific outcome categories were not mutually exclusive. Stage 1 accounted for 122/194 (62.9%) ETT-related and 131/182 (72.0%) NGT-related cases. Mean time from insertion to first detection was 8.93 ± 3.77 days for ETT-related injuries and 7.70 ± 3.14 days for NGT-related injuries. Conclusions: Device-related pressure injuries were frequently recorded in this selected ICU cohort, predominantly as Stage 1 injuries. These descriptive findings emphasize the clinical relevance of systematic device-site observation and precise outcome documentation and can inform local surveillance priorities and prospective prevention studies.
Related
- Efficacy and Safety of Etomidate Versus Ketamine for Endotracheal Intubation in Critically Ill Patients: A Systematic Review and Meta-Analysis
- Non-Pressure Skin Failure in Critically Ill Adults: Applying the Newly Updated NPIAP Definition to Assess Incidence, Risk Factors and Predictive Tools. A Prospective Cohort Study.
- Development and pilot feasibility testing of an evidence-based endotracheal tube maintenance protocol for critically ill patients: A delphi consensus study
- Using capnography to differentiate airway from gastrointestinal placement of nasogastric tubes: a prospective multicentre diagnostic accuracy study
- Continuous versus intermittent endotracheal tube cuff pressure control for the prevention of ventilator-associated pneumonia: A focused systematic review and exploratory meta-analysis.
BibTeX
@article{elsayed2026endotracheal,
title = {{Endotracheal and Nasogastric Tube-Related Pressure Injuries in Critically Ill Adults: A Prospective Descriptive Cohort Study.}},
author = {Shimmaa Mohamed Elsayed and Rabie Adel El Arab and Mona Saad Abdelwareth and Nermine Mohamed Elcokany and Mohamed Mahmoud Seweid},
journal = {Nursing reports (Pavia, Italy)},
year = {2026},
month = nov,
doi = {10.3390/nursrep16110410},
url = {https://europepmc.org/article/MED/43083487},
note = {CC BY},
}
RIS
TY - JOUR
TI - Endotracheal and Nasogastric Tube-Related Pressure Injuries in Critically Ill Adults: A Prospective Descriptive Cohort Study.
AU - Shimmaa Mohamed Elsayed
AU - Rabie Adel El Arab
AU - Mona Saad Abdelwareth
AU - Nermine Mohamed Elcokany
AU - Mohamed Mahmoud Seweid
PY - 2026
DA - 2026/11/16
JO - Nursing reports (Pavia, Italy)
DO - 10.3390/nursrep16110410
UR - https://europepmc.org/article/MED/43083487
AB - Background/Objectives: Medical device-related pressure injuries (MDRPIs) are a concern in intensive care nursing, and device-specific evidence from Egypt remains limited. This study aimed to describe the occurrence, stages, and time to first detection of endotracheal tube (ETT)- and nasogastric tube (NGT)-related pressure injuries among critically ill adults. Methods: A prospective observational cohort included 210 adults requiring both devices in three intensive care units (ICUs) at an Egyptian university hospital. One researcher conducted admission screening and subsequent skin assessments every 12 h for up to 30 days; suspected injuries were confirmed by ICU surveillance nurses. Findings were summarized descriptively. Results: ETT-related injuries occurred in 194/210 patients (92.4%), and NGT-related injuries occurred in 182/210 patients (86.7%). All participants received both devices, and the device-specific outcome categories were not mutually exclusive. Stage 1 accounted for 122/194 (62.9%) ETT-related and 131/182 (72.0%) NGT-related cases. Mean time from insertion to first detection was 8.93 ± 3.77 days for ETT-related injuries and 7.70 ± 3.14 days for NGT-related injuries. Conclusions: Device-related pressure injuries were frequently recorded in this selected ICU cohort, predominantly as Stage 1 injuries. These descriptive findings emphasize the clinical relevance of systematic device-site observation and precise outcome documentation and can inform local surveillance priorities and prospective prevention studies.
SN - 2039-439X
SN - 2039-4403
ER -