Skip to content
DraconiticResearch
Search Sources API
203,234 studies31 sourcesUpdated 22 min ago
Peer-reviewedCC BY 4.0Frontiers in Cardiovascular Medicine

Cutaneous warning signs of cardiac implantable electronic device infection: a pictorial guide for clinicians

  1. 1Department of Cardiology, University Hospital of Brest
  2. 2Laboratoire ORPHY EA 4324, University Brest
  3. 3Dermatology, Private Practice

Abstract

Cardiac implantable electronic device (CIED) infections are potentially life-threatening complications of pacemakers, implantable cardioverter-defibrillators, and cardiac resynchronization therapy devices. Although fever, bacteremia, and infective endocarditis may occur, the earliest—and sometimes only—manifestations are cutaneous abnormalities overlying the generator pocket. These findings may be subtle and mistaken for postoperative changes, hematoma, contact dermatitis, mechanical irritation, or impaired wound healing. Because patients may initially present to general practitioners, internists, emergency physicians, or dermatologists, early recognition is essential. This pictorial review illustrates the spectrum of cutaneous manifestations of CIED infection, ranging from localized erythema, swelling, pain, and delayed wound healing to erosion, sinus tract formation, purulent drainage, necrosis, and hardware exposure. It also highlights practical warning signs, appropriate referral pathways, and interventions that should be avoided before specialist assessment. Infection may extend from the pocket along the intravascular leads to the bloodstream and cardiac structures, leading to bacteremia, endocarditis, sepsis, and death. Any persistent or progressive abnormality over a CIED pocket warrants prompt evaluation, whereas purulent drainage, sinus formation, or hardware exposure should be considered evidence of device infection and require urgent electrophysiology assessment, even in the absence of systemic symptoms.

Related

  1. Increase in Reimbursement Does Not Necessarily Place a Financial Burden on Patients ― Background Behind the Reimbursement Revision for Remote Monitoring of Cardiac Implantable Electronic Devices in Japan ―
    Takashi Ashihara
    Circulation JournalPeer-reviewedLicence not statedFull textCardiovascular medicineJ-STAGE
  2. Changes in Remote Monitoring for Patients With Cardiac Implantable Electronic Devices After a Reimbursement Revision ― An Interrupted Time-Series Analysis ―
    Koki Takegawa, Koshiro Kanaoka, Haruka Matsuura +4
    Circulation JournalPeer-reviewedCC BY-NC-NDFull textCardiovascular medicineJ-STAGE
  3. Persistent pocket-site pain after cardiac implantable electronic device implantation: a prospective observational study of prevalence, neuropathic characteristics, and quality of life.
    Gozde Altun, Ayla Esin, Yasemin Ozsahin +5
    BMC anesthesiologyPeer-reviewedCC BY-NC-NDFull textCardiovascular medicineEurope PMCDOAJ
  4. TricValve System Implantation in Patients With Cardiac Implantable Electronic Devices: A Multicentre Observational Study
    Kira Osipenko, Iuliana Coti, Paul Werner +26
    European Journal of Cardio-Thoracic SurgeryPeer-reviewedCC BY 4.0Full textCardiovascular medicinePMC
  5. Age-stratified clinical phenotypes of cardiac implantable electronic device infections: a 20-year retrospective cohort study
    Sameer Al-Maisary, Migdat Mustafi, Gabriele Romano +4
    BMC Cardiovascular DisordersPeer-reviewedCC BY 4.0Full textCardiovascular medicinePMCDOAJ
BibTeX
@article{kerkouri2026cutaneous,
  title = {{Cutaneous warning signs of cardiac implantable electronic device infection: a pictorial guide for clinicians}},
  author = {Fawzi Kerkouri and Amine El Ouahidi and Vincent Mansourati and Yves Le Ru and Jacques Mansourati},
  journal = {Frontiers in Cardiovascular Medicine},
  year = {2026},
  month = nov,
  doi = {10.3389/fcvm.2026.2001066},
  url = {https://www.frontiersin.org/articles/10.3389/fcvm.2026.2001066/full},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Cutaneous warning signs of cardiac implantable electronic device infection: a pictorial guide for clinicians
AU  - Fawzi Kerkouri
AU  - Amine El Ouahidi
AU  - Vincent Mansourati
AU  - Yves Le Ru
AU  - Jacques Mansourati
PY  - 2026
DA  - 2026/11/09
JO  - Frontiers in Cardiovascular Medicine
DO  - 10.3389/fcvm.2026.2001066
UR  - https://www.frontiersin.org/articles/10.3389/fcvm.2026.2001066/full
AB  - Cardiac implantable electronic device (CIED) infections are potentially life-threatening complications of pacemakers, implantable cardioverter-defibrillators, and cardiac resynchronization therapy devices. Although fever, bacteremia, and infective endocarditis may occur, the earliest—and sometimes only—manifestations are cutaneous abnormalities overlying the generator pocket. These findings may be subtle and mistaken for postoperative changes, hematoma, contact dermatitis, mechanical irritation, or impaired wound healing. Because patients may initially present to general practitioners, internists, emergency physicians, or dermatologists, early recognition is essential. This pictorial review illustrates the spectrum of cutaneous manifestations of CIED infection, ranging from localized erythema, swelling, pain, and delayed wound healing to erosion, sinus tract formation, purulent drainage, necrosis, and hardware exposure. It also highlights practical warning signs, appropriate referral pathways, and interventions that should be avoided before specialist assessment. Infection may extend from the pocket along the intravascular leads to the bloodstream and cardiac structures, leading to bacteremia, endocarditis, sepsis, and death. Any persistent or progressive abnormality over a CIED pocket warrants prompt evaluation, whereas purulent drainage, sinus formation, or hardware exposure should be considered evidence of device infection and require urgent electrophysiology assessment, even in the absence of systemic symptoms.
SN  - 2297-055X
ER  -