Digital-Twin-in-the-Loop Dual-Layer Time–Frequency Decomposition and Capacity Configuration of Hybrid Energy Storage for Wind Power

Abstract

INTRODUCTION: Conventional hybrid energy storage sizing often relies on fixed frequency thresholds and insufficiently considers device constraints and economic objectives. This study proposes a digital-twin-in-the-loop capacity configuration method based on dual-layer time–frequency decoupling. METHODS: ICEEMDAN was used to decompose wind power, while power, energy, and duration characteristics were extracted for mode classification. SGMD was applied only to transition modes identified from battery, supercapacitor, and PCS capabilities. SAC determined the SGMD parameters and critical-mode allocation ratios. Initial capacities were obtained from the 95th-percentile power and cumulative energy trajectories and corrected through multi-scenario digital-twin evaluation. RESULTS: For a 50 MW wind farm, the final battery and supercapacitor capacities were 1.53 MW/2.65 MWh and 0.50 MW/0.10 MWh, respectively. The total cost was RMB 31.2561 million, corresponding to reductions of 15.75% and 8.76% relative to the single-layer ICEEMDAN configuration and the fixed-parameter ICEEMDAN+SGMD configuration considered in the component-wise comparison. Rapid grid-power fluctuations were also reduced. CONCLUSION: The proposed method coordinates time-scale separation, device constraints, and configuration economy, providing an effective approach for wind-power hybrid energy storage planning.

Related

  1. The Capacity of Private Information Retrieval from Coded Storage Systems with Colluding, Robust and Byzantine Servers
    Rui Sun, Yiwei Zhang
    arXivPreprintarXiv licenceFull textGeneral mathematicsarXiv
  2. Constrained Capacity for Faster-than-Nyquist Signaling in Frequency-Selective Fading Channels
    Zichao Zhang, Melda Yuksel, Gokhan M. Guvensen +1
    arXivPreprintarXiv licenceFull textGeneral mathematicsarXiv
  3. On a Digital Signature Based on Matrix Decomposition and the MinRank Problem
    Miguel Ángel López
    arXivPreprintCC BY-SA 4.0Full textAlgebra & number theoryarXiv
  4. High-Fidelity Digital Twin Data Models by Randomized Dynamic Mode Decomposition and Deep Learning with Applications in Fluid Dynamics
    Diana A. Bistrian
    arXivPreprintCC BY 4.0Full textNumerical analysis & scientific computingarXiv
  5. Maximality and configuration spaces on real algebraic curves
    Aloïs Demory
    arXivPreprintCC BY 4.0Full textAlgebra & number theoryarXiv
BibTeX
@article{ye2026digitaltwinintheloop,
  title = {{Digital-Twin-in-the-Loop Dual-Layer Time–Frequency Decomposition and Capacity Configuration of Hybrid Energy Storage for Wind Power}},
  author = {Peng Ye and Lin Qu and Huan Wang and Xuejie Wang},
  journal = {EAI Endorsed Transactions on Energy Web},
  year = {2026},
  month = oct,
  doi = {10.4108/ew.15646},
  url = {https://doi.org/10.4108/ew.15646},
  note = {CC BY-NC-SA},
}
RIS
TY  - JOUR
TI  - Digital-Twin-in-the-Loop Dual-Layer Time–Frequency Decomposition and Capacity Configuration of Hybrid Energy Storage for Wind Power
AU  - Peng Ye
AU  - Lin Qu
AU  - Huan Wang
AU  - Xuejie Wang
PY  - 2026
DA  - 2026/10/23
JO  - EAI Endorsed Transactions on Energy Web
DO  - 10.4108/ew.15646
UR  - https://doi.org/10.4108/ew.15646
AB  - INTRODUCTION: Conventional hybrid energy storage sizing often relies on fixed frequency thresholds and insufficiently considers device constraints and economic objectives. This study proposes a digital-twin-in-the-loop capacity configuration method based on dual-layer time–frequency decoupling. METHODS: ICEEMDAN was used to decompose wind power, while power, energy, and duration characteristics were extracted for mode classification. SGMD was applied only to transition modes identified from battery, supercapacitor, and PCS capabilities. SAC determined the SGMD parameters and critical-mode allocation ratios. Initial capacities were obtained from the 95th-percentile power and cumulative energy trajectories and corrected through multi-scenario digital-twin evaluation. RESULTS: For a 50 MW wind farm, the final battery and supercapacitor capacities were 1.53 MW/2.65 MWh and 0.50 MW/0.10 MWh, respectively. The total cost was RMB 31.2561 million, corresponding to reductions of 15.75% and 8.76% relative to the single-layer ICEEMDAN configuration and the fixed-parameter ICEEMDAN+SGMD configuration considered in the component-wise comparison. Rapid grid-power fluctuations were also reduced. CONCLUSION: The proposed method coordinates time-scale separation, device constraints, and configuration economy, providing an effective approach for wind-power hybrid energy storage planning.
SN  - 2032-944X
ER  -