Comparison of anterior segment parameters in cataract patients with different axial lengths using IOL Master and Pentacam

  1. 1Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Ophthalmology & Visual Sciences Key Laboratory, No.1, Dong Jiao Min Xiang, Dong Cheng District, Beijing, 100730 China
  2. 2Shandong Second Medical University, Weifang, Shandong 261000 China

Abstract

Background: To evaluate the agreement and clinical interchangeability of anterior segment parameters measured by Swept-Source Optical Coherence Tomography (SS-OCT, IOL Master 700) and Scheimpflug imaging (Pentacam HR) across a continuous spectrum of axial lengths (AL).

Methods: This retrospective study consecutively included 294 cataract patients (294 eyes) divided into six AL subgroups. Central corneal thickness (CCT), anterior chamber depth (ACD), white-to-white (WTW) distance, and mean keratometry (Km) were measured under undilated conditions by a single technician. Relative reliability was evaluated using Intraclass Correlation Coefficients (ICC). Absolute agreement was analyzed using Bland-Altman limits of agreement (LoA) and compared against predefined clinical tolerance thresholds. One-way Analysis of Variance (ANOVA) was performed to determine whether inter-device measurement discrepancies (Δ) varied systematically across AL subgroups.

Results: Relative reliability was excellent for ACD, CCT, and Km (ICCs > 0.88), but moderate for WTW (ICC = 0.641). Bland-Altman analysis revealed consistent systematic differences. The 95% LoA widths for CCT (31.32 μm), WTW (0.826 mm), and Km (1.274 D) significantly exceeded a priori clinical thresholds. The LoA width for ACD (0.233 mm) marginally exceeded the strict threshold. Crucially, ANOVA demonstrated no statistically significant variations in measurement discrepancies across all six AL subgroups (all P > 0.05).

Conclusions: Inter-device measurement biases between the IOL Master 700 and Pentacam HR are remarkably stable and are not exacerbated by extreme AL. These inherent biases stem from differing optical principles rather than patient-specific ocular geometries. Given that the LoA widths consistently exceed clinical tolerance thresholds, these devices are not clinically interchangeable for individual precise surgical planning.

Supplementary Information: The online version contains supplementary material available at https://doi.org/10.1186/s12886-026-05204-x.

Related

  1. Anterior Capsule Contrast and Capsulorhexis Geometry Across Visualization Systems in Cataract Surgery: An Exploratory Image-Based Comparison
    Journal of clinical medicinePeer-reviewedCC BYFull textGeneral medicineEurope PMC
  2. Long-term visual outcomes and rotational stability of two diffractive toric intraocular lenses with different design combinations in cataract patients with long axial length
    Shuang Ni, Yongwei Zhou, Zhen Zhang +3
    Frontiers in medicinePeer-reviewedCC BYFull textGeneral medicineEurope PMC
  3. Comparison of Visual and Ocular Hemodynamic Outcomes Following Trifocal vs Bifocal Intraocular Lens Implantation in Patients With Cataract and Myopia.
    Man Xu, Yan Shao, Xing Gao +1
    Medical science monitor : international medical journal of experimental and clinical researchPeer-reviewedCC BY-NC-NDFull textGeneral medicineEurope PMC
  4. Effect of steep-axis incisions on anterior and posterior corneal astigmatism and higher-order aberrations after cataract surgery
    Kaiyue Du, Kaiyue Du, Zhan Shen +9
    Frontiers in MedicinePeer-reviewedCC BYFull textGeneral medicineDOAJEurope PMCPMC
  5. Comparison of subjective outcomes between single-bundle and double-bundle anterior cruciate ligament reconstruction in patients with flat lateral tibial slope
    Shang-Yu Yao, Keng-Yi Lin, Yi-Sheng Chan +6
    Acta Orthopaedica et Traumatologica TurcicaPeer-reviewedCC BY-NC 4.0Full textSurgery & anaesthesiaPMC
BibTeX
@article{tian2026comparison,
  title = {{Comparison of anterior segment parameters in cataract patients with different axial lengths using IOL Master and Pentacam}},
  author = {Zhi-Yong Tian and Peng Zhao and Zhong-Yan Li and Zhi Chen and Jing-Shang Zhang and Ying-Yan Mao and Xiu-Hua Wan and Meng Li},
  journal = {BMC Ophthalmology},
  year = {2026},
  month = aug,
  doi = {10.1186/s12886-026-05204-x},
  url = {https://doi.org/10.1186/s12886-026-05204-x},
  note = {CC BY-NC-ND 4.0},
}
RIS
TY  - JOUR
TI  - Comparison of anterior segment parameters in cataract patients with different axial lengths using IOL Master and Pentacam
AU  - Zhi-Yong Tian
AU  - Peng Zhao
AU  - Zhong-Yan Li
AU  - Zhi Chen
AU  - Jing-Shang Zhang
AU  - Ying-Yan Mao
AU  - Xiu-Hua Wan
AU  - Meng Li
PY  - 2026
DA  - 2026/08/07
JO  - BMC Ophthalmology
DO  - 10.1186/s12886-026-05204-x
UR  - https://doi.org/10.1186/s12886-026-05204-x
AB  - Background: To evaluate the agreement and clinical interchangeability of anterior segment parameters measured by Swept-Source Optical Coherence Tomography (SS-OCT, IOL Master 700) and Scheimpflug imaging (Pentacam HR) across a continuous spectrum of axial lengths (AL).  Methods: This retrospective study consecutively included 294 cataract patients (294 eyes) divided into six AL subgroups. Central corneal thickness (CCT), anterior chamber depth (ACD), white-to-white (WTW) distance, and mean keratometry (Km) were measured under undilated conditions by a single technician. Relative reliability was evaluated using Intraclass Correlation Coefficients (ICC). Absolute agreement was analyzed using Bland-Altman limits of agreement (LoA) and compared against predefined clinical tolerance thresholds. One-way Analysis of Variance (ANOVA) was performed to determine whether inter-device measurement discrepancies (Δ) varied systematically across AL subgroups.  Results: Relative reliability was excellent for ACD, CCT, and Km (ICCs > 0.88), but moderate for WTW (ICC = 0.641). Bland-Altman analysis revealed consistent systematic differences. The 95% LoA widths for CCT (31.32 μm), WTW (0.826 mm), and Km (1.274 D) significantly exceeded a priori clinical thresholds. The LoA width for ACD (0.233 mm) marginally exceeded the strict threshold. Crucially, ANOVA demonstrated no statistically significant variations in measurement discrepancies across all six AL subgroups (all P > 0.05).  Conclusions: Inter-device measurement biases between the IOL Master 700 and Pentacam HR are remarkably stable and are not exacerbated by extreme AL. These inherent biases stem from differing optical principles rather than patient-specific ocular geometries. Given that the LoA widths consistently exceed clinical tolerance thresholds, these devices are not clinically interchangeable for individual precise surgical planning.  Supplementary Information: The online version contains supplementary material available at https://doi.org/10.1186/s12886-026-05204-x.
SN  - 1471-2415
ER  -