Quantitative membranous septum area assessment with advanced three-dimensional CT visualization with a mixed reality-capable device.
8 affiliations
- 1CORRIB Research Centre for Advanced Imaging and Core Laboratory, University of Galway, University Road, Galway H91 TK33, Ireland.
- 2Department of Anatomy, School of Medicine, College of Medicine, Nursing and Health Sciences, University of Galway, Galway H91 W5P7, Ireland.
- 3Department of Anatomy and Regenerative Medicine, RCSI University of Medicine and Health Sciences, Dublin 2, D02 YN77, Ireland.
- 4MedApp S. A., Krakow, Poland.
- 5Department of Measurement and Electronics, AGH University of Krakow, Krakow, Poland.
- 6CÚRAM, Centre for Research in Medical Devices, University of Galway, Galway, Ireland.
- 7Department of Mechanical Engineering, University College London, London, United Kingdom.
- 8Division of Cardiology, Department of Medicine, McGill University Health Center, Montreal, Quebec, Canada.
Abstract
Aims
Permanent pacemaker implantation (PPI) rates remained elevated for patients receiving transcatheter aortic valve implantation for aortic stenosis (AS) and aortic regurgitation. Therefore, detailed assessment of the membranous septum (MS) anatomy is essential to understand the mechanism and mitigate risk. This study aims to examine the accuracy and reproducibility of a novel 3D hologram system to measure transcatheter aortic valve implantation-related aortic valvar complex anatomy and present a novel methodology to measure MS area with it.Methods and results
Cardiac computer tomography series of AS, aortic regurgitation, and coronary artery disease (CAD) patient cohorts were analysed using CarnaLife Holo (MedApp SA, Kraków, Poland) to quantify and compare their MS areas. 3mensio Structural Heart was used as a benchmark comparator, with annulus area (AA) selected as the quantitative parameter. Intraclass correlation coefficient values between the software all exceeded 0.99, with no statistically significant difference noted between AA measurements. Bland-Altman plotting illustrated narrow boundaries of agreement, with no significant outliers. In interobserver agreement analysis for 3D hologram, AA measurements were not significantly different between two investigators (P = 0.906). No significant difference was found between the MS areas between the three cohorts after ANOVA testing (P = 0.1640).Conclusion
3D holographic software provides a feasible and reproducible tool for visualising and measuring the aortic valvar complex anatomy. In addition, its ability to assess the shape, pattern, and area of the MS offers anatomic insights not readily available with other software.
Related
- Three-dimensional Reconstruction of Membranous Umbilical Vessels from MR Imaging Assists Delivery Planning
- Treatment of Cherry Angiomas With a 1064-nm Long-Pulse Laser: A Multi-Time-Point, Multi-Dimensional Quantitative Assessment Based on Antera 3D.
- Stable reporter-expressing rubella virus for quantitative monitoring and real-time visualization of infection dynamics.
- Longitudinal Radiomics for Predicting Short-Term Efficacy in Locally Advanced Nasopharyngeal Carcinoma Based on Transformer and SHAP Visualization Analysis: A Multicenter Study
- Quantitative Molecular Breast Imaging for Early Prediction of Neoadjuvant Systemic Therapy Response in Locally Advanced Breast Cancer Patients
BibTeX
@article{osullivan2026quantitative,
title = {{Quantitative membranous septum area assessment with advanced three-dimensional CT visualization with a mixed reality-capable device.}},
author = {Cian O'Sullivan and Tsung-Ying Tsai and Hao-Wei Lee and Fei-Ran Chiou and Rachel Beatty and Maciej Stanuch and Andrzej Skalski and Akihiro Tobe and Garry P Duffy and Brendan Wilkins and Ryo Torii and Nicolo Piazza and Yoshinobu Onuma and Patrick W Serruys},
journal = {European heart journal. Digital health},
year = {2026},
month = oct,
doi = {10.1093/ehjdh/ztag167},
url = {https://europepmc.org/article/MED/43054830},
note = {CC BY},
}
RIS
TY - JOUR
TI - Quantitative membranous septum area assessment with advanced three-dimensional CT visualization with a mixed reality-capable device.
AU - Cian O'Sullivan
AU - Tsung-Ying Tsai
AU - Hao-Wei Lee
AU - Fei-Ran Chiou
AU - Rachel Beatty
AU - Maciej Stanuch
AU - Andrzej Skalski
AU - Akihiro Tobe
AU - Garry P Duffy
AU - Brendan Wilkins
AU - Ryo Torii
AU - Nicolo Piazza
AU - Yoshinobu Onuma
AU - Patrick W Serruys
PY - 2026
DA - 2026/10/22
JO - European heart journal. Digital health
DO - 10.1093/ehjdh/ztag167
UR - https://europepmc.org/article/MED/43054830
AB - Aims Permanent pacemaker implantation (PPI) rates remained elevated for patients receiving transcatheter aortic valve implantation for aortic stenosis (AS) and aortic regurgitation. Therefore, detailed assessment of the membranous septum (MS) anatomy is essential to understand the mechanism and mitigate risk. This study aims to examine the accuracy and reproducibility of a novel 3D hologram system to measure transcatheter aortic valve implantation-related aortic valvar complex anatomy and present a novel methodology to measure MS area with it.Methods and results Cardiac computer tomography series of AS, aortic regurgitation, and coronary artery disease (CAD) patient cohorts were analysed using CarnaLife Holo (MedApp SA, Kraków, Poland) to quantify and compare their MS areas. 3mensio Structural Heart was used as a benchmark comparator, with annulus area (AA) selected as the quantitative parameter. Intraclass correlation coefficient values between the software all exceeded 0.99, with no statistically significant difference noted between AA measurements. Bland-Altman plotting illustrated narrow boundaries of agreement, with no significant outliers. In interobserver agreement analysis for 3D hologram, AA measurements were not significantly different between two investigators (P = 0.906). No significant difference was found between the MS areas between the three cohorts after ANOVA testing (P = 0.1640).Conclusion 3D holographic software provides a feasible and reproducible tool for visualising and measuring the aortic valvar complex anatomy. In addition, its ability to assess the shape, pattern, and area of the MS offers anatomic insights not readily available with other software.
SN - 2634-3916
ER -