Skip to content
DraconiticResearch
Search Sources API
277,308 studies31 sourcesUpdated 20 min ago
Peer-reviewedCC BYSkin research and technology : official journal of International Society for Bioengineering and the Skin (ISBS) [and] International Society for Digital Imaging of Skin (ISDIS) [and] International Society for Skin Imaging (ISSI)

Treatment of Cherry Angiomas With a 1064-nm Long-Pulse Laser: A Multi-Time-Point, Multi-Dimensional Quantitative Assessment Based on Antera 3D.

  1. 1Department of Cosmetology, Wenzhou Hospital of Integrated Traditional Chinese and Western Medicine, Affiliated Zhejiang Chinese Medical University, Wenzhou, Zhejiang, China.
  2. 2Department of Wenzhou Key Laboratory of Laser Cosmetology, Wenzhou Hospital of Integrated Traditional Chinese and Western Medicine, Affiliated Zhejiang Chinese Medical University, Wenzhou, Zhejiang, China.
  3. 3Department of Anhui University of Chinese Medicine, Hefei, Anhui, China.

Abstract

Background and objective

Cherry angioma (CA) is a common benign cutaneous vascular proliferative lesion that predominantly affects middle-aged and elderly individuals. The long-pulsed 1064 nm Nd:YAG laser (LP-Nd:YAG laser) is an effective treatment for CA; however, previous studies have lacked quantitative descriptions of the immediate post-treatment response and its correlation with clinical efficacy. This study aims to quantitatively evaluate the immediate response to LP-Nd:YAG laser treatment for CA and investigate its association with final clinical outcomes.Methods

A total of 129 CAs in 20 patients treated between December 2024 and January 2025 were enrolled. The red color ratio (RCR) was used to quantify the degree of redness, and the improvement rate reflected the pre-to post-treatment changes. Clinical photographs were taken using a digital camera, and three-dimensional multispectral images were acquired using the Antera 3D system at three time points: baseline (T0), immediately post-treatment (T1), and 2 months post-treatment (T2), to assess mean hemoglobin concentration (HbI), redness score, RCR, and lesion volume. Two physicians specializing in aesthetic medicine blindly evaluated clinical efficacy using a binary scoring system. The correlation between the percentage decrease in HbI at T1 (ΔHbI%) and the clinical score at T2 was analysed. A receiver operating characteristic (ROC) curve was used to determine the optimal ΔHbI% cutoff for predicting "complete clearance" at 2 months.The primary analysis was performed on a per-patient basis, with lesion-level analysis as a sensitivity analysis.Results

HbI decreased significantly from 28.24 ± 7.05 at baseline to 13.76 ± 3.26 immediately post-treatment (p < 0.001), and further to 5.83 ± 4.52 at 2 months (p < 0.001). There was no significant difference in intrinsic laser responsiveness between elevated and flat CAs; after adjusting for baseline HbI, the difference in ΔHbI% between the two groups was not statistically significant (F = 0.057, p = 0.812). ΔHbI% was significantly associated with complete clearance at 2 months (GEE: OR = 1.23, 95% CI: 1.10-1.39, p < 0.001). In the per-patient ROC analysis, the AUC of ΔHbI% for predicting complete clearance at 2 months was 0.802 (95% CI: 0.588-1.000), with an optimal cutoff value of 50.1%, sensitivity of 66.7%, and specificity of 87.5%. In the lesion-level sensitivity analysis, the AUC was 0.93 (95% CI: 0.72-1.00), with an optimal cutoff value of 39.0%, sensitivity of 92.4%, and specificity of 90.9%.Conclusion

Based on clinical observations and Antera 3D imaging assessments, LP-Nd:YAG laser treatment for CA demonstrates good overall efficacy and a favorable safety profile. Antera 3D can sensitively capture the immediate physiological response to laser therapy, and the degree of immediate blood flow reduction may serve as an early predictor of the final clinical outcome.Clinical trial registration information

ChiCTR2400092847.

Related

  1. Quantitative membranous septum area assessment with advanced three-dimensional CT visualization with a mixed reality-capable device.
    Cian O'Sullivan, Tsung-Ying Tsai, Hao-Wei Lee +11
    European heart journal. Digital healthPeer-reviewedCC BYFull textCardiovascular medicineEurope PMCPMC
  2. A quantitative treatment assessment for optimizing combined virotherapy-chemotherapy regimens against HPV-induced cervical cancer
    Salil Ghosh, Amit Kumar Bag, Satyajit Mukherjee +3
    PLOS OnePeer-reviewedCC BY 4.0Full textOncologyPLOS
  3. From orchard to table: Insight into the dissipation, metabolism, processing and risk assessment of 14 pesticides in sweet cherry
    Kai Cui, Liping Fang, Ruiyan Ding +7
    Food Chemistry: XPeer-reviewedCC BYFull textNutritionDOAJEurope PMCEurope PMCPMC
  4. Pelvic venous disorders: Objective hemodynamic signature from quantitative two-dimensional phase-contrast magnetic resonance imaging
    Shih-Chung Wang, Chen-Yu Li, Chih-Chen Kao +9
    Journal of vascular surgery. Venous and lymphatic disordersPeer-reviewedCC BYFull textSurgery & anaesthesiaEurope PMC
  5. Quantitative MRI Characterization of Fluid-Related Phenotypes in Pediatric Epilepsy: Deep Learning-Assisted Assessment of Enlarged Perivascular Space Burden, Regional Distribution, and Clinical Associations
    Adil Aytaç, Hilal Aydın
    Diagnostics (Basel, Switzerland)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
BibTeX
@article{tu2026treatment,
  title = {{Treatment of Cherry Angiomas With a 1064-nm Long-Pulse Laser: A Multi-Time-Point, Multi-Dimensional Quantitative Assessment Based on Antera 3D.}},
  author = {Yuanjia Tu and Changhan Chen and Yuzhen Huang and Xiaxia Chen and Youhui Ke and Youhui Ke},
  journal = {Skin research and technology : official journal of International Society for Bioengineering and the Skin (ISBS) [and] International Society for Digital Imaging of Skin (ISDIS) [and] International Society for Skin Imaging (ISSI)},
  year = {2026},
  month = nov,
  doi = {10.1111/srt.70407},
  url = {https://europepmc.org/article/MED/43052206},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Treatment of Cherry Angiomas With a 1064-nm Long-Pulse Laser: A Multi-Time-Point, Multi-Dimensional Quantitative Assessment Based on Antera 3D.
AU  - Yuanjia Tu
AU  - Changhan Chen
AU  - Yuzhen Huang
AU  - Xiaxia Chen
AU  - Youhui Ke
AU  - Youhui Ke
PY  - 2026
DA  - 2026/11/01
JO  - Skin research and technology : official journal of International Society for Bioengineering and the Skin (ISBS) [and] International Society for Digital Imaging of Skin (ISDIS) [and] International Society for Skin Imaging (ISSI)
DO  - 10.1111/srt.70407
UR  - https://europepmc.org/article/MED/43052206
AB  - Background and objective  Cherry angioma (CA) is a common benign cutaneous vascular proliferative lesion that predominantly affects middle-aged and elderly individuals. The long-pulsed 1064 nm Nd:YAG laser (LP-Nd:YAG laser) is an effective treatment for CA; however, previous studies have lacked quantitative descriptions of the immediate post-treatment response and its correlation with clinical efficacy. This study aims to quantitatively evaluate the immediate response to LP-Nd:YAG laser treatment for CA and investigate its association with final clinical outcomes.Methods  A total of 129 CAs in 20 patients treated between December 2024 and January 2025 were enrolled. The red color ratio (RCR) was used to quantify the degree of redness, and the improvement rate reflected the pre-to post-treatment changes. Clinical photographs were taken using a digital camera, and three-dimensional multispectral images were acquired using the Antera 3D system at three time points: baseline (T0), immediately post-treatment (T1), and 2 months post-treatment (T2), to assess mean hemoglobin concentration (HbI), redness score, RCR, and lesion volume. Two physicians specializing in aesthetic medicine blindly evaluated clinical efficacy using a binary scoring system. The correlation between the percentage decrease in HbI at T1 (ΔHbI%) and the clinical score at T2 was analysed. A receiver operating characteristic (ROC) curve was used to determine the optimal ΔHbI% cutoff for predicting "complete clearance" at 2 months.The primary analysis was performed on a per-patient basis, with lesion-level analysis as a sensitivity analysis.Results  HbI decreased significantly from 28.24 ± 7.05 at baseline to 13.76 ± 3.26 immediately post-treatment (p < 0.001), and further to 5.83 ± 4.52 at 2 months (p < 0.001). There was no significant difference in intrinsic laser responsiveness between elevated and flat CAs; after adjusting for baseline HbI, the difference in ΔHbI% between the two groups was not statistically significant (F = 0.057, p = 0.812). ΔHbI% was significantly associated with complete clearance at 2 months (GEE: OR = 1.23, 95% CI: 1.10-1.39, p < 0.001). In the per-patient ROC analysis, the AUC of ΔHbI% for predicting complete clearance at 2 months was 0.802 (95% CI: 0.588-1.000), with an optimal cutoff value of 50.1%, sensitivity of 66.7%, and specificity of 87.5%. In the lesion-level sensitivity analysis, the AUC was 0.93 (95% CI: 0.72-1.00), with an optimal cutoff value of 39.0%, sensitivity of 92.4%, and specificity of 90.9%.Conclusion  Based on clinical observations and Antera 3D imaging assessments, LP-Nd:YAG laser treatment for CA demonstrates good overall efficacy and a favorable safety profile. Antera 3D can sensitively capture the immediate physiological response to laser therapy, and the degree of immediate blood flow reduction may serve as an early predictor of the final clinical outcome.Clinical trial registration information  ChiCTR2400092847.
SN  - 0909-752X
SN  - 1600-0846
ER  -