Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 5 min ago
Peer-reviewedCC BYCureus

Comparison of Two Polypropylene Meshes With Different Areal Densities in Open Lichtenstein Repair of Primary Inguinal Hernia: A Prospective, Quasi-Randomized Controlled Trial.

  1. 1General Surgery, Ganesh Shankar Vidyarthi Memorial Medical College, Kanpur, IND.
  2. 2Anatomy, Ganesh Shankar Vidyarthi Memorial Medical College, Kanpur, IND.
  3. 3Community and Family Medicine, Ganesh Shankar Vidyarthi Memorial Medical College, Kanpur, IND.

Abstract

Background and objective

Chronic and early postoperative pain remain important concerns after open inguinal hernia repair, and mesh characteristics may influence these outcomes. This trial compared ultralightweight (<35 g/m²) with lightweight (35-70 g/m²) polypropylene mesh in Lichtenstein repair, focusing on postoperative pain and hernia recurrence, to determine whether a further reduction in mesh density improves pain outcomes without compromising efficacy in working-age men.Methods

In this single-center, parallel-group controlled trial with alternate (quasi-random) allocation, 80 men aged 18-60 years with primary inguinal hernia were allocated 1:1 to ultralightweight (<35 g/m²) or lightweight (35-70 g/m²) polypropylene mesh (n=40 per group) during Lichtenstein hernioplasty. Postoperative pain was assessed on a visual analog scale (VAS) at postoperative day (POD) 1, one week, six weeks, six months, and one year. Recurrence, operative time, hospital stay, early complications, and chronic pain (>3 months) were also recorded.Results

Baseline demographics (age, body mass index, hernia side, Nyhus type) were comparable between groups. Operative time was similar (47.90 ± 7.99 vs 48.15 ± 8.25 min; p=0.891), and hospital stay trended shorter with ultralightweight mesh (3.07 ± 0.27 vs 3.23 ± 0.42 days; p=0.061). VAS pain scores were significantly lower with ultralightweight mesh at POD 1 (2.90 ± 0.81 vs 4.72 ± 1.18; mean difference -1.82, 95% CI -2.27 to -1.38; p<0.001) and at one and six weeks (p<0.001), but converged by six months and one year. Early complications were comparable (seroma 7.5% vs 10%; hematoma 5% vs 7.5%). Chronic pain occurred less often with ultralightweight mesh, though the difference was not statistically significant (0% vs 7.5%; p=0.239). No recurrence was observed in either group.Conclusions

Ultralightweight mesh reduced early postoperative pain compared with lightweight mesh in Lichtenstein hernioplasty, with a comparable early complication profile. No recurrence was observed in either group during one year of follow-up; however, the trial was not powered to detect differences in recurrence. Ultralightweight mesh was associated with lower early postoperative pain scores in working-age men, but longer, adequately powered studies are needed to assess recurrence and durability.

Related

  1. Comparison of analgesic efficacy and safety between liposomal bupivacaine and ropivacaine for paravertebral block in patients undergoing thoracoscopic lung tumor surgery: a prospective double-blind randomized controlled trial
    Journal of thoracic diseasePeer-reviewedCC BY-NC-NDFull textGeneral medicineEurope PMC
  2. Multidimensional Comparison of Abobotulinumtoxin A 100 Units and Neubotulinumtoxin A 33.33 Units for the Treatment of Hemifacial Spasm: A 50-Week Prospective, Double-Blind, Randomized Crossover Controlled Trial.
    Subsai Kongsaengdao, Kanoksri Samintharapanya
    ToxinsPeer-reviewedCC BYFull textNeurologyEurope PMC
  3. Comparison of the efficacy of self-gripping mesh and sutured mesh in lichtenstein inguinal hernia repair: a meta-analysis and GRADE assessment
    Tao Jiang, Yuejuan Li, Hui Dong
    BMC SurgeryPeer-reviewedCC BY-NC-ND 4.0Full textSurgery & anaesthesiaPMC
  4. Comparison of Sugammadex and Neostigmine for Reversal of Vecuronium-Induced Neuromuscular Blockade in Pediatric Patients: A Prospective Randomized Study
    Neha Tiwari, Aarti Agarwal, Shilpi Verma +4
    CureusPeer-reviewedCC BYFull textGeneral medicineEurope PMC
  5. Comparison of Metronidazole Gel and Povidone‑Iodine for Vaginal Preparation in Preventing Post‑Cesarean Infection‑Related Morbidity: A Three‑Group Randomized Controlled Trial
    Fatemeh Davodabadi, Hamideh Parsapour, Behzad Imani +2
    Health science reportsPeer-reviewedCC BYFull textGeneral medicineEurope PMC
BibTeX
@article{singh2026comparison,
  title = {{Comparison of Two Polypropylene Meshes With Different Areal Densities in Open Lichtenstein Repair of Primary Inguinal Hernia: A Prospective, Quasi-Randomized Controlled Trial.}},
  author = {Ekansh H Singh and Raj Kumar Singh and Ashish K Chaudhary and Arti and Abhinav Sengar and Pooja Chaudhary},
  journal = {Cureus},
  year = {2026},
  month = oct,
  doi = {10.7759/cureus.118246},
  url = {https://europepmc.org/article/MED/43061592},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Comparison of Two Polypropylene Meshes With Different Areal Densities in Open Lichtenstein Repair of Primary Inguinal Hernia: A Prospective, Quasi-Randomized Controlled Trial.
AU  - Ekansh H Singh
AU  - Raj Kumar Singh
AU  - Ashish K Chaudhary
AU  - Arti
AU  - Abhinav Sengar
AU  - Pooja Chaudhary
PY  - 2026
DA  - 2026/10/20
JO  - Cureus
DO  - 10.7759/cureus.118246
UR  - https://europepmc.org/article/MED/43061592
AB  - Background and objective  Chronic and early postoperative pain remain important concerns after open inguinal hernia repair, and mesh characteristics may influence these outcomes. This trial compared ultralightweight (<35 g/m²) with lightweight (35-70 g/m²) polypropylene mesh in Lichtenstein repair, focusing on postoperative pain and hernia recurrence, to determine whether a further reduction in mesh density improves pain outcomes without compromising efficacy in working-age men.Methods  In this single-center, parallel-group controlled trial with alternate (quasi-random) allocation, 80 men aged 18-60 years with primary inguinal hernia were allocated 1:1 to ultralightweight (<35 g/m²) or lightweight (35-70 g/m²) polypropylene mesh (n=40 per group) during Lichtenstein hernioplasty. Postoperative pain was assessed on a visual analog scale (VAS) at postoperative day (POD) 1, one week, six weeks, six months, and one year. Recurrence, operative time, hospital stay, early complications, and chronic pain (>3 months) were also recorded.Results  Baseline demographics (age, body mass index, hernia side, Nyhus type) were comparable between groups. Operative time was similar (47.90 ± 7.99 vs 48.15 ± 8.25 min; p=0.891), and hospital stay trended shorter with ultralightweight mesh (3.07 ± 0.27 vs 3.23 ± 0.42 days; p=0.061). VAS pain scores were significantly lower with ultralightweight mesh at POD 1 (2.90 ± 0.81 vs 4.72 ± 1.18; mean difference -1.82, 95% CI -2.27 to -1.38; p<0.001) and at one and six weeks (p<0.001), but converged by six months and one year. Early complications were comparable (seroma 7.5% vs 10%; hematoma 5% vs 7.5%). Chronic pain occurred less often with ultralightweight mesh, though the difference was not statistically significant (0% vs 7.5%; p=0.239). No recurrence was observed in either group.Conclusions  Ultralightweight mesh reduced early postoperative pain compared with lightweight mesh in Lichtenstein hernioplasty, with a comparable early complication profile. No recurrence was observed in either group during one year of follow-up; however, the trial was not powered to detect differences in recurrence. Ultralightweight mesh was associated with lower early postoperative pain scores in working-age men, but longer, adequately powered studies are needed to assess recurrence and durability.
SN  - 2168-8184
ER  -