Skip to content
DraconiticResearch
Search Sources API
277,308 studies31 sourcesUpdated 22 min ago
Peer-reviewedCC BY-NC-ND 4.0BMC Surgery

Comparison of the efficacy of self-gripping mesh and sutured mesh in lichtenstein inguinal hernia repair: a meta-analysis and GRADE assessment

  1. 1Department of General Surgery, Zigong Fourth People’s Hospital, 1331 Ziwei Rd., Ziliujing Dist, Zigong, 643000 Sichuan China

Abstract

Background: Lichtenstein inguinal hernia repair is a common surgical procedure. Self-gripping mesh, a novel mesh that does not require suturing, has emerged as a potential alternative to traditional sutured mesh. This study aimed to evaluate the efficacy differences between self-gripping and sutured meshes in this surgery through a meta-analysis.

Methods: Randomized controlled trials (RCTs) that met the inclusion criteria were identified through database searches in PubMed, Embase, Cochrane Library, and Web of Science. Meta-analysis was performed using Cochrane RevMan 5.4 software, and the quality of evidence was assessed using the Grading of Recommendations Assessment, Development, and Evaluation (GRADE) approach.

Results: Nineteen RCTs involving 4301 patients were included. The meta-analysis showed that compared to the sutured mesh group, the self-gripping mesh group had significantly shorter surgical time [mean difference (MD) = -6.99 min, 95% confidence interval (CI) (-8.73, -5.25), P < 0.00001], and a lower postoperative 24-hour pain score [MD = -1.51, 95% CI (-2.95, -0.07), P = 0.04]. No significant differences were observed between the two groups regarding length of hospital stay, 1-year postoperative chronic pain incidence, 2-year postoperative chronic pain incidence, seroma incidence, hematoma incidence, and recurrence rate. No significant publication bias was found. GRADE assessment showed that the quality of evidence for surgical time, length of hospital stay, and 24-hour postoperative pain score was low, while other outcomes were of moderate quality.

Conclusion: Current evidence suggests that self-gripping mesh may reduce surgical time and early postoperative pain in Lichtenstein inguinal hernia repair. However, given the low quality of evidence for these outcomes, the findings should be interpreted cautiously. Further high-quality RCTs are needed to confirm these findings.

Supplementary Information: The online version contains supplementary material available at https://doi.org/10.1186/s12893-026-04064-y.

Related

  1. Comparison of Two Polypropylene Meshes With Different Areal Densities in Open Lichtenstein Repair of Primary Inguinal Hernia: A Prospective, Quasi-Randomized Controlled Trial.
    Ekansh H Singh, Raj Kumar Singh, Ashish K Chaudhary +3
    CureusPeer-reviewedCC BYFull textSurgery & anaesthesiaEurope PMCPMC
  2. Efficacy of laparoscopic transabdominal preperitoneal (TAPP) and totally extraperitoneal (TEP) repair in the treatment of bilateral inguinal hernia: a systematic review and meta-analysis
    Yulin Pan, Xiao Pang, Pan Shen +1
    Frontiers in SurgeryPeer-reviewedCC BY 4.0Full textSurgery & anaesthesiaPMC
  3. Access without excess: a comparison of wound infections with disposable versus hybrid trocars in minimally invasive inguinal hernia repairs
    Kimberly P. Woo, Ali Alipouriani, Abby Gross +23
    Surgical EndoscopyPeer-reviewedCC BY 4.0Full textSurgery & anaesthesiaPMC
  4. The Postoperative Analgesic Efficacy of Two Bupivacaine Concentrations for Combined Ilioinguinal and Iliohypogastric Nerve Block After Inguinal Hernia Repair Under Spinal Anesthesia: Prospective Double-Blinded, Randomized Research.
    Mariam Elkasass, Hala Mohey El-Deen El-Gendy, Mohammad Ali Mohammad +1
    Anesthesiology research and practicePeer-reviewedCC BYFull textSurgery & anaesthesiaEurope PMCPMC
  5. Comparison of ultrasound-guided modified thoracoabdominal nerve block through perichondrial approach (M-TAPA) and lateral transversus abdominis plane block on postoperative pain and quality of recovery after laparoscopic inguinal hernia repair: a prospective observational comparative study
    İnan Sarıdede, Öznur Demiroluk, Doğa Meriç Yükselen +2
    BMC AnesthesiologyPeer-reviewedCC BY 4.0Full textSurgery & anaesthesiaPMC
BibTeX
@article{jiang2026comparison,
  title = {{Comparison of the efficacy of self-gripping mesh and sutured mesh in lichtenstein inguinal hernia repair: a meta-analysis and GRADE assessment}},
  author = {Tao Jiang and Yuejuan Li and Hui Dong},
  journal = {BMC Surgery},
  year = {2026},
  month = aug,
  doi = {10.1186/s12893-026-04064-y},
  url = {https://doi.org/10.1186/s12893-026-04064-y},
  note = {CC BY-NC-ND 4.0},
}
RIS
TY  - JOUR
TI  - Comparison of the efficacy of self-gripping mesh and sutured mesh in lichtenstein inguinal hernia repair: a meta-analysis and GRADE assessment
AU  - Tao Jiang
AU  - Yuejuan Li
AU  - Hui Dong
PY  - 2026
DA  - 2026/08/18
JO  - BMC Surgery
DO  - 10.1186/s12893-026-04064-y
UR  - https://doi.org/10.1186/s12893-026-04064-y
AB  - Background: Lichtenstein inguinal hernia repair is a common surgical procedure. Self-gripping mesh, a novel mesh that does not require suturing, has emerged as a potential alternative to traditional sutured mesh. This study aimed to evaluate the efficacy differences between self-gripping and sutured meshes in this surgery through a meta-analysis.  Methods: Randomized controlled trials (RCTs) that met the inclusion criteria were identified through database searches in PubMed, Embase, Cochrane Library, and Web of Science. Meta-analysis was performed using Cochrane RevMan 5.4 software, and the quality of evidence was assessed using the Grading of Recommendations Assessment, Development, and Evaluation (GRADE) approach.  Results: Nineteen RCTs involving 4301 patients were included. The meta-analysis showed that compared to the sutured mesh group, the self-gripping mesh group had significantly shorter surgical time [mean difference (MD) = -6.99 min, 95% confidence interval (CI) (-8.73, -5.25), P < 0.00001], and a lower postoperative 24-hour pain score [MD = -1.51, 95% CI (-2.95, -0.07), P = 0.04]. No significant differences were observed between the two groups regarding length of hospital stay, 1-year postoperative chronic pain incidence, 2-year postoperative chronic pain incidence, seroma incidence, hematoma incidence, and recurrence rate. No significant publication bias was found. GRADE assessment showed that the quality of evidence for surgical time, length of hospital stay, and 24-hour postoperative pain score was low, while other outcomes were of moderate quality.  Conclusion: Current evidence suggests that self-gripping mesh may reduce surgical time and early postoperative pain in Lichtenstein inguinal hernia repair. However, given the low quality of evidence for these outcomes, the findings should be interpreted cautiously. Further high-quality RCTs are needed to confirm these findings.  Supplementary Information: The online version contains supplementary material available at https://doi.org/10.1186/s12893-026-04064-y.
SN  - 1471-2482
ER  -