Aging-Improved NH3 Sensing in Polypyrrole Nanotube Chemiresistors

Abstract

Polypyrrole NH3 chemiresistors in nanotube (NT) and planar film (PF) morphologies are compared on response magnitude, limit of detection (LOD), sensitivity, and response/recovery kinetics, including the performance of the same sensors tracked over 60 days of ambient storage and repeated NH3 exposure. In the case of fresh sensors, the time constants for the fast process (τ1) is shorter in the NT than in the PF at every concentration. NT is 38 \% faster on average than PF. The slow process (τ2) overlaps between two morphologies and shows no concentration dependence. The two time constants differentiate the two morphologies through aging: NT τ1 and τ2 decrease substantially and monotonically over 60 days, while the time constants of PF show no consistent trend. All measured sensing parameters, LOD, sensor response and sensitivity improve or at least remain stable with aging in the case of NT, while all parameters degrade in the PF case. These improved sensor performance and aging identify the nanotube morphology as the more robust and manufacturable choice for long-term NH3 sensing applications.

Related

  1. Dynamic Sensing via Photomodulated Gas Desorption in Plasmonic Nanoparticle Chemiresistors
    Lukas Mielke, Dahee Heo, Gabriele Carelli +1
    arXivPreprintarXiv licenceFull textApplied physics & instrumentationCondensed matterarXiv
  2. Cover Feature: Stress‐Programmed Microcrack Networks in Gallium–Carbon Nanotube Thin Films for Plasma‐Active and Electroresponsive Antibacterial Interfaces (Small Struct. 10/2026)
    Tarek Khater, Shaohong Luo, Thành Trần‐Phú +14
    Small StructuresPeer-reviewedCC BYFull textGeneral chemistryGeneral physicsDOAJ
  3. Compact Modeling of Oxide-Semiconductor, 2D Material, Carbon Nanotube, and Cryogenic Transistors with Experiment Verification
    Chien-Ting Tung
    arXivPreprintCC BY 4.0Full textApplied physics & instrumentationCondensed matterarXiv
  4. Resonant enhancement of Raman scattering in a MoS2 nanotube
    D. R. Kazanov, A. V. Poshakinskiy
    arXivPreprintarXiv licenceFull textCondensed matterarXiv
  5. Reducing the Gate-Induced Drain-Leakage Current of Carbon-Nanotube Transistors by Subliming Dispersants with Back-End-of-Line Compatible Temperature
    Takumi Inaba, Yuichi Kato, Yoko Iizumi +4
    arXivPreprintCC BY-NC-ND 4.0Full textCondensed matterarXiv
BibTeX
@misc{mohan2026agingimproved,
  title = {{Aging-Improved NH$_3$ Sensing in Polypyrrole Nanotube Chemiresistors}},
  author = {Arya Mohan and Olivia Kamdom and Antoine Enel and Benoît Hackens},
  howpublished = {arXiv},
  year = {2026},
  month = nov,
  doi = {10.48550/arxiv.2611.04917},
  eprint = {2611.04917},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2611.04917},
}
RIS
TY  - UNPB
TI  - Aging-Improved NH_3 Sensing in Polypyrrole Nanotube Chemiresistors
AU  - Arya Mohan
AU  - Olivia Kamdom
AU  - Antoine Enel
AU  - Benoît Hackens
PY  - 2026
DA  - 2026/11/03
PB  - arXiv
DO  - 10.48550/arxiv.2611.04917
UR  - https://arxiv.org/abs/2611.04917
AB  - Polypyrrole NH_3 chemiresistors in nanotube (NT) and planar film (PF) morphologies are compared on response magnitude, limit of detection (LOD), sensitivity, and response/recovery kinetics, including the performance of the same sensors tracked over 60 days of ambient storage and repeated NH_3 exposure. In the case of fresh sensors, the time constants for the fast process (τ_1) is shorter in the NT than in the PF at every concentration. NT is 38 \% faster on average than PF. The slow process (τ_2) overlaps between two morphologies and shows no concentration dependence. The two time constants differentiate the two morphologies through aging: NT τ_1 and τ_2 decrease substantially and monotonically over 60 days, while the time constants of PF show no consistent trend. All measured sensing parameters, LOD, sensor response and sensitivity improve or at least remain stable with aging in the case of NT, while all parameters degrade in the PF case. These improved sensor performance and aging identify the nanotube morphology as the more robust and manufacturable choice for long-term NH_3 sensing applications.
ER  -