Skip to content
DraconiticResearch
Search Sources API
203,203 studies31 sourcesUpdated 44 min ago
PreprintarXiv licencearXiv

An Acousto-Optic Colorimeter

Abstract

Uniform color spaces and color-difference formulae rest on visual data obtained almost entirely with surface samples and conventional displays, whose primaries confine the measurements to a limited chromaticity range. The highly saturated region of color space is therefore the least measured part of human color perception, at the moment when quantum-dot, microLED, and laser displays have begun to operate inside it. Closing this gap requires stimuli more saturated than any fixed-primary device can produce, together with the stability and uniformity demanded by visual experiments. We present an acousto-optic colorimeter built for this purpose. A four-channel acousto-optic tunable filter selects narrow spectral components from a supercontinuum laser over the calibrated range of 443--660~nm, with measured linewidths of 1.37--3.20~nm; the wavelength and radiance of every component are set electronically, so the primary set itself becomes an experimental variable. A compact diffuser--light-pipe homogenizer combines the selected components into a uniform observation field, and spectral feedback stabilizes their intensities. The calibrated primary set covered 95\% of the area enclosed by the CIE 1964 10∘ spectral locus in the x,y chromaticity plane. The calculated maximum luminance reached 1406~cd\,m−2, with 328~cd\,m−2 available at the gray Robertson chromaticity. Across an 18-mm observation field the mean spatial ΔE00 difference was 0.913, and five Robertson color centers reproduced under continuous feedback gave mean target errors of 0.34--1.26~ΔE00 over 10-min intervals. The instrument thus delivers calibrated, uniform, and stable highly saturated stimuli, and is intended to extend the empirical basis of color-difference measurement into the region where data are still absent.

Related

  1. Large Language Model Steering of Acousto-Optic Tweezer Arrays
    Cheng Sheng, Kai-xuan Xiao, Yin Zhang +5
    arXivPreprintarXiv licenceFull textAtomic, molecular & optical physicsQuantum physics & quantum informationarXiv
  2. Resonance-enhanced integrated acousto-optic beam steering.
    Yue Yu, Qixuan Lin, Shucheng Fang +8
    Nature communicationsPeer-reviewedCC BY-NC-NDFull textOptics & photonicsEurope PMC
  3. Acoustoelectrically enhanced acousto-optic modulation in an integrated silicon nitride and thin film lithium niobate platform
    Matthew J. Storey, John H. Dallyn, Kiyan Hocek +5
    arXivPreprintCC BY 4.0Full textOptics & photonicsarXiv
  4. A Low-Temperature Tool for Acousto-electric Detection
    Rohit Mandlik, Sunil Nair
    arXivPreprintarXiv licenceFull textApplied physics & instrumentationCondensed matterarXiv
  5. Dissipative acousto-mechanical parametric interface between high-overtone acoustics and flexural phonons
    Xun Ji, Huanying Sun, Longhao Wu +4
    arXivPreprintCC BY-NC-ND 4.0Full textCondensed matterOptics & photonicsarXiv
BibTeX
@misc{aksentsev2026acoustooptic,
  title = {{An Acousto-Optic Colorimeter}},
  author = {Pavel Aksentsev and Georgiy Lobarev and Sergey Korchagin and Olga Polschikova and Egor Ershov},
  howpublished = {arXiv},
  year = {2026},
  month = oct,
  doi = {10.48550/arxiv.2610.07988},
  eprint = {2610.07988},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2610.07988},
}
RIS
TY  - UNPB
TI  - An Acousto-Optic Colorimeter
AU  - Pavel Aksentsev
AU  - Georgiy Lobarev
AU  - Sergey Korchagin
AU  - Olga Polschikova
AU  - Egor Ershov
PY  - 2026
DA  - 2026/10/06
PB  - arXiv
DO  - 10.48550/arxiv.2610.07988
UR  - https://arxiv.org/abs/2610.07988
AB  - Uniform color spaces and color-difference formulae rest on visual data obtained almost entirely with surface samples and conventional displays, whose primaries confine the measurements to a limited chromaticity range. The highly saturated region of color space is therefore the least measured part of human color perception, at the moment when quantum-dot, microLED, and laser displays have begun to operate inside it. Closing this gap requires stimuli more saturated than any fixed-primary device can produce, together with the stability and uniformity demanded by visual experiments. We present an acousto-optic colorimeter built for this purpose. A four-channel acousto-optic tunable filter selects narrow spectral components from a supercontinuum laser over the calibrated range of 443--660~nm, with measured linewidths of 1.37--3.20~nm; the wavelength and radiance of every component are set electronically, so the primary set itself becomes an experimental variable. A compact diffuser--light-pipe homogenizer combines the selected components into a uniform observation field, and spectral feedback stabilizes their intensities. The calibrated primary set covered 95\% of the area enclosed by the CIE 1964 10^∘ spectral locus in the x,y chromaticity plane. The calculated maximum luminance reached 1406~cd\,m^−2, with 328~cd\,m^−2 available at the gray Robertson chromaticity. Across an 18-mm observation field the mean spatial ΔE_00 difference was 0.913, and five Robertson color centers reproduced under continuous feedback gave mean target errors of 0.34--1.26~ΔE_00 over 10-min intervals. The instrument thus delivers calibrated, uniform, and stable highly saturated stimuli, and is intended to extend the empirical basis of color-difference measurement into the region where data are still absent.
ER  -