Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 17 min ago
Peer-reviewedCC BY-NC-SA 4.0Endoscopic Ultrasound

Defining the optimal technique for a novel EUS platform combining two-dimensional shear wave elastography and attenuation imaging: A preclinical study

4 affiliations
  1. 1Division of Gastroenterology, Hepatology, and Endoscopy, Brigham and Women’s Hospital, Boston, MA, USA
  2. 2Division of Gastroenterology and Hepatology, Digestive Health Institute, Hoag Memorial Hospital Presbyterian, Hoag Health, Newport Beach, CA, USA
  3. 3Department of Gastroenterology and Nutrition, Geisinger Medical Center, Danville, PA, USA
  4. 4Digestive Health Institute, University of California Irvine School of Medicine, Orange, CA, USA.

Abstract

Background and Objectives:: Noninvasive diagnostics have become an integral part of the evaluation of patients with chronic liver diseases. Ultrasound-based elastography estimates the degree of fibrosis within the liver by measuring the speed through which shear waves, generated from a push-pulse, propagate through the liver. Ultrasound can also be used to estimate the degree of hepatic steatosis by measuring the attenuation of sound waves through the liver. Ultrasound-based elastography and attenuation typically use a transabdominal probe, though recent developments allow for both two-dimensional shear wave elastography (2D-SWE) and attenuation imaging (ATI) through a curvilinear echoendoscope. The aim of this study was to define the optimal technique for 2D EUS-SWE ATI and to compare performance with currently available modalities.

Methods:: A curvilinear echoendoscope was used to test the accuracy of measurements compared with a hydrogel reference model for different regions of interest depth, size, placement method, and number of measurements. These measurements were then repeated by 5 expert endosonographers using surgically implanted reference models in porcine liver. Statistical analysis was performed using R (version 4.4.1, R Core Team 2021, Vienna, Austria).

Results:: Optimal settings for region of interest size, depth, placement, and number were identified. Accuracy (defined by % deviation from reference) of SWE was highest for 2D-SWE compared with conventional modalities, while accuracy of the novel platform’s ATI was similar to the controlled attenuation parameter. There was excellent interobserver agreement using the novel platform with optimal technique (intraclass correlation coefficient of 0.999 [P < 0.001]).

Conclusions:: Our study serves as the basis for obtaining measurements with optimal accuracy using a novel EUS-based platform combining 2D-SWE and ATI. In this preclinical model, the novel platform demonstrated excellent accuracy across a broad range of reference models, with excellent interobserver agreement, and was more accurate than conventional modalities using point SWE.

Related

  1. Perineal incisional hernia: A technique combining a gluteus maximus flap and a synthetic prosthesis via the perineal approach
    Haitham Khalil, Julia Berthelot, Edouard Roussel
    Journal of Visceral SurgeryPeer-reviewedCC BYSurgery & anaesthesiaHAL
  2. A Novel MR Elastography Device for Preclinical Applications From Spheroids to Rodents: Design, Validation, and Performance Evaluation
    Gabrielle Mangin, Hannah Fels‐palesandro, Valéria Bisio +12
    NMR in BiomedicinePeer-reviewedCC BY 4.0Full textMedical imaging & radiologyHAL
  3. Comparison of a model combining conventional ultrasonography and strain elastography with ACR TI-RADS for reducing unnecessary fine-needle aspiration in solid-predominant partially cystic thyroid nodules: a multicenter study.
    Yuguo Wang, Wangxing Huang, Hanzhong Qi +4
    Gland surgeryPeer-reviewedCC BY-NC-NDFull textEndocrinology & metabolismEurope PMCPMC
  4. Combining shear wave elastography and ultrasound localization microscopy for liver fibrosis staging in a rat model
    Yue Zhang, Haoming Lin, Xinli Kong +6
    European Radiology ExperimentalPeer-reviewedCC BY 4.0Full textMedical imaging & radiologyPMC
  5. Assessment of biopsy‐proven liver fibrosis by two‐dimensional shear wave elastography: An individual patient data‐based meta‐analysis
    Eva Herrmann, Victor de Lédinghen, Christophe Cassinotto +28
    HepatologyPeer-reviewedHAL deposit licenceFull text466 citedSystems & synthetic biologyMedical imaging & radiologyHAL
BibTeX
@article{konyn2026defining,
  title = {{Defining the optimal technique for a novel EUS platform combining two-dimensional shear wave elastography and attenuation imaging: A preclinical study}},
  author = {Peter Konyn and Kenneth J. Chang and David L. Diehl and Harshit S. Khara and Jason B. Samarasena and Marvin Ryou},
  journal = {Endoscopic Ultrasound},
  year = {2026},
  month = oct,
  doi = {10.1097/eus.0000000000000229},
  url = {https://doi.org/10.1097/eus.0000000000000229},
  note = {CC BY-NC-SA 4.0},
}
RIS
TY  - JOUR
TI  - Defining the optimal technique for a novel EUS platform combining two-dimensional shear wave elastography and attenuation imaging: A preclinical study
AU  - Peter Konyn
AU  - Kenneth J. Chang
AU  - David L. Diehl
AU  - Harshit S. Khara
AU  - Jason B. Samarasena
AU  - Marvin Ryou
PY  - 2026
DA  - 2026/10/09
JO  - Endoscopic Ultrasound
DO  - 10.1097/eus.0000000000000229
UR  - https://doi.org/10.1097/eus.0000000000000229
AB  - Background and Objectives:: Noninvasive diagnostics have become an integral part of the evaluation of patients with chronic liver diseases. Ultrasound-based elastography estimates the degree of fibrosis within the liver by measuring the speed through which shear waves, generated from a push-pulse, propagate through the liver. Ultrasound can also be used to estimate the degree of hepatic steatosis by measuring the attenuation of sound waves through the liver. Ultrasound-based elastography and attenuation typically use a transabdominal probe, though recent developments allow for both two-dimensional shear wave elastography (2D-SWE) and attenuation imaging (ATI) through a curvilinear echoendoscope. The aim of this study was to define the optimal technique for 2D EUS-SWE ATI and to compare performance with currently available modalities.  Methods:: A curvilinear echoendoscope was used to test the accuracy of measurements compared with a hydrogel reference model for different regions of interest depth, size, placement method, and number of measurements. These measurements were then repeated by 5 expert endosonographers using surgically implanted reference models in porcine liver. Statistical analysis was performed using R (version 4.4.1, R Core Team 2021, Vienna, Austria).  Results:: Optimal settings for region of interest size, depth, placement, and number were identified. Accuracy (defined by % deviation from reference) of SWE was highest for 2D-SWE compared with conventional modalities, while accuracy of the novel platform’s ATI was similar to the controlled attenuation parameter. There was excellent interobserver agreement using the novel platform with optimal technique (intraclass correlation coefficient of 0.999 [P < 0.001]).  Conclusions:: Our study serves as the basis for obtaining measurements with optimal accuracy using a novel EUS-based platform combining 2D-SWE and ATI. In this preclinical model, the novel platform demonstrated excellent accuracy across a broad range of reference models, with excellent interobserver agreement, and was more accurate than conventional modalities using point SWE.
SN  - 2303-9027
SN  - 2226-7190
ER  -