Abstract
Formaldehyde is one of the main indoor pollutants. Active green walls (AGWS) are an effective method for purifying formaldehyde. Existing numerical models of AGWS lack accurate representations of the plant module. This study constructed a dynamic formaldehyde fumigation system, analyzed the formaldehyde purification performance of AGWS under given conditions, and analyzed the moisture content and temperature of the green wall bed layer. The moisture content parameters obtained from the experiments were used to optimize the theoretical model, and a simulation study was conducted to investigate the performance of the AGWS to purify formaldehyde indoors. The experimental study found that as the air supply speed increased, the value of single pass removal efficiency (SPRE) decreased from 34.5% to 24.75%, the value of elimination capacity (EC) increased from 13.51 mg/(m2·h) to 22.63 mg/(m2·h), and the clean air delivery rate (CADR) increased from 4.14 m3/h to 6.93 m3/h. The simulation study found that under the 36 different conditions set up, 32 combined working conditions could ensure that the indoor formaldehyde concentration remained within the safe range at the end of the simulation. In 27 conditions, the total exposure time to formaldehyde risk was less than 10 h, which occurred in most conditions. These results were obtained under constant-velocity airflow, constant temperature (22 °C), and uncontrolled relative humidity; the effects of room pressure differential, variable-frequency fan operation, and humidity variation were not considered.
Related
- Virtual Reality Simulation in Colonoscopy Training: A Systematic Review and Meta-analysis of Studies Published from 2019 to 2024
- Factors influencing baseline electrocardiographic parameters in rats: A systematic review of experimental studies published from 1960 to the present
- A preliminar validation-driven experimental–numerical framework for vaginal delivery simulation
- Comprehensive comparison of six optimization algorithms for automated population pharmacokinetic model selection via two simulation studies and eleven real case studies
- Synthesis of azo metal complexes for efficient photocatalytic diclofenac degradation: experimental studies and statistical optimization.
BibTeX
@article{wu2026experimental,
title = {{Experimental and simulation studies on the formaldehyde purification performance of active green walls}},
author = {Dan Wu and Darui He and Lijun Zuo},
journal = {City and Built Environment},
year = {2026},
month = oct,
doi = {10.1007/s44213-026-00087-6},
url = {https://doi.org/10.1007/s44213-026-00087-6},
note = {CC BY},
}
RIS
TY - JOUR
TI - Experimental and simulation studies on the formaldehyde purification performance of active green walls
AU - Dan Wu
AU - Darui He
AU - Lijun Zuo
PY - 2026
DA - 2026/10/01
JO - City and Built Environment
DO - 10.1007/s44213-026-00087-6
UR - https://doi.org/10.1007/s44213-026-00087-6
AB - Formaldehyde is one of the main indoor pollutants. Active green walls (AGWS) are an effective method for purifying formaldehyde. Existing numerical models of AGWS lack accurate representations of the plant module. This study constructed a dynamic formaldehyde fumigation system, analyzed the formaldehyde purification performance of AGWS under given conditions, and analyzed the moisture content and temperature of the green wall bed layer. The moisture content parameters obtained from the experiments were used to optimize the theoretical model, and a simulation study was conducted to investigate the performance of the AGWS to purify formaldehyde indoors. The experimental study found that as the air supply speed increased, the value of single pass removal efficiency (SPRE) decreased from 34.5% to 24.75%, the value of elimination capacity (EC) increased from 13.51 mg/(m2·h) to 22.63 mg/(m2·h), and the clean air delivery rate (CADR) increased from 4.14 m3/h to 6.93 m3/h. The simulation study found that under the 36 different conditions set up, 32 combined working conditions could ensure that the indoor formaldehyde concentration remained within the safe range at the end of the simulation. In 27 conditions, the total exposure time to formaldehyde risk was less than 10 h, which occurred in most conditions. These results were obtained under constant-velocity airflow, constant temperature (22 °C), and uncontrolled relative humidity; the effects of room pressure differential, variable-frequency fan operation, and humidity variation were not considered.
SN - 2435-7936
ER -