Skip to content
DraconiticResearch
Search Sources API
203,234 studies31 sourcesUpdated 52 min ago
PreprintCC BY 4.0arXiv

Monte Carlo sampling of first-order QED processes in laser and pulsar plasmas

Abstract

Monte Carlo sampling of strong-field quantum electrodynamics processes underpins simulations of high-intensity laser experiments and of astrophysical compact-object magnetospheres. Sampling an event requires the total rate of the process together with the cumulative probability that determines how energy is partitioned between the produced particles. Simulations typically tabulate both in advance and invert the tabulated probability numerically. Here we replace this procedure with elementary-function approximations for synchrotron radiation and the nonlinear Breit--Wheeler process. For each process, we approximate the auxiliary function that sets the total rate, as well as the cumulative probability, with Padé approximants chosen so that the inversion reduces to a quartic equation. This yields the sampled quantum parameter---electron χe or photon χγ---in closed form. The approximations and the particle spectra sampled from them agree with the exact results to within 1%. The procedure requires no lookup tables, no interpolation, and no numerical root finding, and can be inserted directly into radiative particle-in-cell codes.

Related

  1. A Delayed Rejection Reversible Jump Markov Chain Monte Carlo Method for Multi-Resolution Maps of the Stochastic Gravitational Wave Background with Pulsar Timing Array Data
    Taha T. Moursy, Nihan S. Pol
    arXivPreprintCC BY 4.0Full textHigh-energy astrophysicsInstrumentation & methodsarXiv
  2. Latin hypercube sampling to reduce the variance in Monte Carlo integration: a practical guide and an application to gravitational-wave astronomy
    Matteo Boschini, Davide Gerosa
    arXivPreprintarXiv licenceFull textCosmologyHigh-energy astrophysicsarXiv
  3. Sequince: a modular sequential Monte Carlo toolkit
    Michael J. Williams, Christian E. A. Chapman-Bird
    arXivPreprintCC BY 4.0Full textInstrumentation & methodsStatisticsarXiv
  4. Multigroup Implicit Monte Carlo Radiation Hydrodynamics on Moving Voronoi Meshes with STORM and RICH
    Maor Mizrachi, Barak Raveh, Elad Steinberg
    arXivPreprintCC BY 4.0Full textInstrumentation & methodsComputational physicsarXiv
  5. Markov Chain Monte Carlo for Bayesian Parametric Galaxy Modeling in LSST
    James J. Buchanan, Michael D. Schneider, Kerianne Pruett +1
    The Astrophysical JournalPeer-reviewedCC BY 4.0Full textGalaxiesCrossref
BibTeX
@misc{sarjomaa2026monte,
  title = {{Monte Carlo sampling of first-order QED processes in laser and pulsar plasmas}},
  author = {Verneri Sarjomaa and Joonas Nättilä},
  howpublished = {arXiv},
  year = {2026},
  month = sep,
  doi = {10.48550/arxiv.2609.29325},
  eprint = {2609.29325},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2609.29325},
  note = {CC BY 4.0},
}
RIS
TY  - UNPB
TI  - Monte Carlo sampling of first-order QED processes in laser and pulsar plasmas
AU  - Verneri Sarjomaa
AU  - Joonas Nättilä
PY  - 2026
DA  - 2026/09/24
PB  - arXiv
DO  - 10.48550/arxiv.2609.29325
UR  - https://arxiv.org/abs/2609.29325
AB  - Monte Carlo sampling of strong-field quantum electrodynamics processes underpins simulations of high-intensity laser experiments and of astrophysical compact-object magnetospheres. Sampling an event requires the total rate of the process together with the cumulative probability that determines how energy is partitioned between the produced particles. Simulations typically tabulate both in advance and invert the tabulated probability numerically. Here we replace this procedure with elementary-function approximations for synchrotron radiation and the nonlinear Breit--Wheeler process. For each process, we approximate the auxiliary function that sets the total rate, as well as the cumulative probability, with Padé approximants chosen so that the inversion reduces to a quartic equation. This yields the sampled quantum parameter---electron χ_e or photon χ_γ---in closed form. The approximations and the particle spectra sampled from them agree with the exact results to within 1%. The procedure requires no lookup tables, no interpolation, and no numerical root finding, and can be inserted directly into radiative particle-in-cell codes.
ER  -