Skip to content
DraconiticResearch
Search Sources API
203,234 studies31 sourcesUpdated 50 min ago
Peer-reviewedCC BY-NCBleeding, Thrombosis and Vascular Biology

PO073 | ANALYTICAL VARIABILITY IN FIBRINOGEN TESTING REVEALING FIBRINOGEN LONGMONT: A CASE REPORT

Abstract

Background. Fibrinogen plays a central role in coagulation, as it is cleaved by thrombin into fibrin, which then assembles into a stable clot through sequential steps of protofibril formation and lateral aggregation. Congenital dysfibrinogenemia is a qualitative fibrinogen disorder caused by structural abnormalities that impair coagulation, with variable clinical presentation. Diagnosis can be challenging due to potential discrepancies between assays, and management depends on the clinical phenotype. Fibrinogen Longmont is a rare congenital dysfibrinogenemia caused by a heterozygous mutation in the Bβ chain (Arg166Cys), leading to the production of structurally abnormal fibrinogen molecules linked by aberrant disulfide bonds. It is typically characterized by a discrepancy between antigenic fibrinogen levels, which may be normal, and reduced functional activity. While early fibrin formation is relatively preserved, defective lateral aggregation impairs clot structure. This variant is associated with heterogeneous clinical and laboratory findings and may be challenging to diagnose due to inconsistencies across coagulation assays. Case report. We report the case of an adult male was referred for hematological evaluation for isolated thrombocytopenia in the setting of liver disease, with concomitantly reduced antithrombin activity. Routine coagulation tests were within normal limits, whereas Clauss fibrinogen levels were unmeasurable using a bovine thrombin reagent on an optical analyzer. In contrast, Clauss fibrinogen activity was within the normal range when measured with a human thrombin-based reagent on the electromechanical platform, while antigenic fibrinogen levels assessed by an immunoturbidimetric assay on the analyzer were also normal. These findings highlighted marked assay-dependent variability. Given the unusual discrepancy, further investigation was undertaken, raising suspicion of a congenital fibrinogen variant consistent with fibrinogen Longmont, a condition previously associated with differences between analytical methods and thrombin sources. Indeed, DNA sequencing of exon 4 of the FGB gene confirmed that the patient was heterozygous for fibrinogen Longmont, carrying a point mutation identified as FGB NM_000514.4: c.586C>T (p.Arg196Cys). Conclusions. Fibrinogen Longmont is associated with impaired fibrin polymerization due to defective lateral aggregation, leading to the formation of a translucent clot. In our case, the discrepant fibrinogen results appear to be primarily related to differences in clot detection methods (optical versus electromechanical). The case underscores the importance of employing multiple testing approaches when fibrinogen results are incongruent. This observation highlights the impact of analytical methodology on assay performance and interpretation and supports the added value of molecular analysis, which can be crucial for establishing a definitive diagnosis when functional assays yield inconclusive or unmeasurable results.

Related

  1. Revealing the phytochemical diversity and bioactive potential of caterpillar mushroom (Cordyceps militaris L.) using analytical techniques
    Muhammad Awais Saleem, Aftab Ahmed, Mian Anjum Murtaza +7
    Scientific ReportsPeer-reviewedCC BYFull textPharmacology & toxicologyDOAJ
  2. PO148 | ANALYTICAL DISCREPANCY IN PLATELET COUNTING REVEALING MYH9-RD: A CASE REPORT
    Marco De Girolamo
    Bleeding, Thrombosis and Vascular BiologyPeer-reviewedCC BY-NCFull textCardiovascular medicineDOAJ
  3. Identifying and resolving analytical outliers in lipoprotein(a) immunoassay testing
    Alexandria N. Jackson, Sara P. Wyness, Joseph W. Rudolf +1
    Practical laboratory medicinePeer-reviewedCC BY-NC-NDFull textGeneral medicineEurope PMC
  4. Myocarditis Revealing a Pathogenic Desmoplakin (DSP) Variant: Implications for Genetic Testing Pathways.
    Blend Reka, Jason N Dungu
    CureusPeer-reviewedCC BYFull textCardiovascular medicineEurope PMC
  5. Analytical Agreement and Diagnostic Performance of a Commercial Point-of-Care Lipid Testing System for Lipid Profile and Atherogenic Ratios
    Susana Guadalupe Guzmán-Aquino, Roberto Rivera-Sánchez, Karla Aidee Aguayo-Cerón +7
    Diagnostics (Basel, Switzerland)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
BibTeX
@article{paradiso2026po073,
  title = {{PO073 | ANALYTICAL VARIABILITY IN FIBRINOGEN TESTING REVEALING FIBRINOGEN LONGMONT: A CASE REPORT}},
  author = {Antonella Paradiso},
  journal = {Bleeding, Thrombosis and Vascular Biology},
  year = {2026},
  month = oct,
  url = {https://www.btvb.org/btvb/article/view/889},
  note = {CC BY-NC},
}
RIS
TY  - JOUR
TI  - PO073 | ANALYTICAL VARIABILITY IN FIBRINOGEN TESTING REVEALING FIBRINOGEN LONGMONT: A CASE REPORT
AU  - Antonella Paradiso
PY  - 2026
DA  - 2026/10/26
JO  - Bleeding, Thrombosis and Vascular Biology
UR  - https://www.btvb.org/btvb/article/view/889
AB  - Background. Fibrinogen plays a central role in coagulation, as it is cleaved by thrombin into fibrin, which then assembles into a stable clot through sequential steps of protofibril formation and lateral aggregation. Congenital dysfibrinogenemia is a qualitative fibrinogen disorder caused by structural abnormalities that impair coagulation, with variable clinical presentation. Diagnosis can be challenging due to potential discrepancies between assays, and management depends on the clinical phenotype. Fibrinogen Longmont is a rare congenital dysfibrinogenemia caused by a heterozygous mutation in the Bβ chain (Arg166Cys), leading to the production of structurally abnormal fibrinogen molecules linked by aberrant disulfide bonds. It is typically characterized by a discrepancy between antigenic fibrinogen levels, which may be normal, and reduced functional activity. While early fibrin formation is relatively preserved, defective lateral aggregation impairs clot structure. This variant is associated with heterogeneous clinical and laboratory findings and may be challenging to diagnose due to inconsistencies across coagulation assays. Case report. We report the case of an adult male was referred for hematological evaluation for isolated thrombocytopenia in the setting of liver disease, with concomitantly reduced antithrombin activity. Routine coagulation tests were within normal limits, whereas Clauss fibrinogen levels were unmeasurable using a bovine thrombin reagent on an optical analyzer. In contrast, Clauss fibrinogen activity was within the normal range when measured with a human thrombin-based reagent on the electromechanical platform, while antigenic fibrinogen levels assessed by an immunoturbidimetric assay on the analyzer were also normal. These findings highlighted marked assay-dependent variability. Given the unusual discrepancy, further investigation was undertaken, raising suspicion of a congenital fibrinogen variant consistent with fibrinogen Longmont, a condition previously associated with differences between analytical methods and thrombin sources. Indeed, DNA sequencing of exon 4 of the FGB gene confirmed that the patient was heterozygous for fibrinogen Longmont, carrying a point mutation identified as FGB NM_000514.4: c.586C>T (p.Arg196Cys). Conclusions. Fibrinogen Longmont is associated with impaired fibrin polymerization due to defective lateral aggregation, leading to the formation of a translucent clot. In our case, the discrepant fibrinogen results appear to be primarily related to differences in clot detection methods (optical versus electromechanical). The case underscores the importance of employing multiple testing approaches when fibrinogen results are incongruent. This observation highlights the impact of analytical methodology on assay performance and interpretation and supports the added value of molecular analysis, which can be crucial for establishing a definitive diagnosis when functional assays yield inconclusive or unmeasurable results.
SN  - 2785-5309
ER  -