Skip to content
DraconiticResearch
Search Sources API
203,234 studies31 sourcesUpdated 8 min ago
Peer-reviewedCC BYCureus

A Fabricated Foot Fracture Caused by Deliberate Placement of an External Osseous Fragment: A Case Report.

5 affiliations
  1. 1Orthopaedics, Jordanian Royal Medical Services, Amman, JOR.
  2. 2Faculty of Medicine, Yarmouk University, Irbid, JOR.
  3. 3Orthopaedic Surgery, Jordanian Royal Medical Services, Amman, JOR.
  4. 4Orthopaedics and Traumatology, Ministry of Health, Amman, JOR.
  5. 5Orthopaedics and Traumatology, Jordanian Royal Medical Services, Irbid, JOR.

Abstract

Accurate diagnosis of musculoskeletal injuries requires correlation between clinical and radiological findings. Although plain radiographs are essential for fracture assessment, external objects may mimic osseous pathology and lead to misdiagnosis. We present an unusual case of a fabricated foot fracture caused by deliberate placement of an external osseous fragment for secondary gain. A 23-year-old previously healthy man presented with left foot pain and inability to bear weight following a reported low-energy fall at his military base. Initial radiographs demonstrated an apparent osseous fragment adjacent to the first metatarsal, provisionally interpreted as a fracture, and the patient was treated with below-knee cast immobilization. On follow-up, repeat radiographs showed an unexpected change in the fragment's position. Computed tomography demonstrated that the fragment was external to the foot and embedded within the cast material, with no true fracture. During supervised repeat radiography, the patient was observed deliberately positioning the fragment adjacent to the foot and subsequently admitted to fabricating the injury to obtain sick leave. Discrepancies between clinical findings and serial radiographs should prompt careful reassessment and consideration of external artifacts. Recognition of unexpected changes in the position of an apparent fracture fragment may prevent unnecessary immobilization, investigations, and treatment, particularly when secondary gain is suspected.

Related

  1. External ventricular drainage management in pediatrics: a simulated scenario for rapid-cycle deliberate practice
    Ruana Luiz Ferreira Da Silva, Ana Railka de Souza Oliveira-Kumakura
    Revista Brasileira de EnfermagemPeer-reviewedCC BYFull textPhysiologyHAL
  2. Posterior Plating Through a Single Posterolateral Approach for a Comminuted Thurston-Holland Fragment in a Pediatric Triplane Ankle Fracture
    Andrés Felipe Muñoz Leiva, Daniel Orlando Ibarra Alva
    CureusPeer-reviewedCC BYFull textGeneral medicineEurope PMC
  3. Conservative Management of a Complicated Crown Fracture Using Autogenous Fragment Reattachment and Fiber Reinforcement: A Case Report
    Nithin S Reddy, Ashwija Shetty, Hajira A Sultana +2
    CureusPeer-reviewedCC BYFull textGeneral medicineEurope PMCPMC
  4. Minimally invasive biological fixation of comminuted navicular fracture using semi-circular external fixator combined with Kirschner wire: a case report.
    Haixiang Sun, Zhenglin Niu, Yue Lian +1
    Annals of jointPeer-reviewedCC BY-NC-NDFull textSurgery & anaesthesiaEurope PMC
  5. Development and external validation of a preoperative prediction model for in-hospital major adverse cardiovascular events after hip fracture surgery in older adults: a retrospective two-center study.
    Ruimin Luo, Jirong Yang, Jieqiang Du +5
    BMC geriatricsPeer-reviewedCC BY-NC-NDFull textSurgery & anaesthesiaEurope PMCDOAJ
BibTeX
@article{hseinat2026fabricated,
  title = {{A Fabricated Foot Fracture Caused by Deliberate Placement of an External Osseous Fragment: A Case Report.}},
  author = {Laith Hseinat and Majdala Al-Bataineh and Hamza A Abu-Ain and Refat AlRawashdeh and Qais Sharayah and Fayiz Samarah and Mutaz Jaloody and Qusai Alqarqaz and Ashraf Albadaineh and Mahmoud Sbaihat},
  journal = {Cureus},
  year = {2026},
  month = sep,
  doi = {10.7759/cureus.117100},
  url = {https://europepmc.org/article/MED/42953889},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - A Fabricated Foot Fracture Caused by Deliberate Placement of an External Osseous Fragment: A Case Report.
AU  - Laith Hseinat
AU  - Majdala Al-Bataineh
AU  - Hamza A Abu-Ain
AU  - Refat AlRawashdeh
AU  - Qais Sharayah
AU  - Fayiz Samarah
AU  - Mutaz Jaloody
AU  - Qusai Alqarqaz
AU  - Ashraf Albadaineh
AU  - Mahmoud Sbaihat
PY  - 2026
DA  - 2026/09/28
JO  - Cureus
DO  - 10.7759/cureus.117100
UR  - https://europepmc.org/article/MED/42953889
AB  - Accurate diagnosis of musculoskeletal injuries requires correlation between clinical and radiological findings. Although plain radiographs are essential for fracture assessment, external objects may mimic osseous pathology and lead to misdiagnosis. We present an unusual case of a fabricated foot fracture caused by deliberate placement of an external osseous fragment for secondary gain. A 23-year-old previously healthy man presented with left foot pain and inability to bear weight following a reported low-energy fall at his military base. Initial radiographs demonstrated an apparent osseous fragment adjacent to the first metatarsal, provisionally interpreted as a fracture, and the patient was treated with below-knee cast immobilization. On follow-up, repeat radiographs showed an unexpected change in the fragment's position. Computed tomography demonstrated that the fragment was external to the foot and embedded within the cast material, with no true fracture. During supervised repeat radiography, the patient was observed deliberately positioning the fragment adjacent to the foot and subsequently admitted to fabricating the injury to obtain sick leave. Discrepancies between clinical findings and serial radiographs should prompt careful reassessment and consideration of external artifacts. Recognition of unexpected changes in the position of an apparent fracture fragment may prevent unnecessary immobilization, investigations, and treatment, particularly when secondary gain is suspected.
SN  - 2168-8184
ER  -