Dynamic Contrast-Enhanced Magnetic Resonance Imaging (DCE-MRI)-Guided Perfusion-Targeted Ultrasound-Stimulated Microbubble Enhancement of Radiation Response in a Xenograft Tumour Model
4 affiliations
- 1Physical Sciences, Sunnybrook Research Institute, Toronto, ON M4N 3M5, Canada
- 2Department of Radiation Oncology, Sunnybrook Health Sciences Center, Toronto, ON M4N 3M5, Canada
- 3Department of Medical Biophysics, University of Toronto, Toronto, ON M5G 1L7, Canada
- 4Department of Radiation Oncology, University of Toronto, Toronto, ON M5T 1P5, Canada
Abstract
Background: Ultrasound-stimulated microbubbles (USMB) have been demonstrated to enhance radiation-based tumour effects through synergistic action at the level of tumour vasculature. Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is a method that can be used for quantitative analysis of tissue vasculature. DCE-MRI parameters allow estimation of tissue perfusion and microvascular status. Methods: In the present study, DCE-MRI parameters were used to guide therapy modulation based on perfusion and were also used to monitor responses to treatment. New Zealand white rabbits bearing human-derived PC3 prostate cancer tumours were assigned to four different groups: untreated controls, animals treated with USMB (14 min; 750 kPa) alone, animals treated with 8 Gy dose of radiation therapy (XRT) alone, and animals treated with a combination of USMB+XRT. Animals receiving combined treatment were categorized in three groups: the first group received USMB+XRT, while the second and third groups received an additional 7 min pulse sequence in a particular area designated as lower perfusion (USMB+XRT, LOW) and high perfusion (USMB+XRT, HIGH), respectively. Treatment response was monitored using DCE-MRI, and changes in parameters were assessed before treatment (baseline) and at 24 h after treatment. Results: Results demonstrated that tumours treated with a combination of USMB and XRT exhibited a decrease in DCE-MRI-based measures of vascular characteristics (USMB+XRT vs. USMB+XRT, HIGH, p < 0.05). Wash-in (s-1) DCE parameters demonstrated a decrease for combined treatment (USMB vs. USMB+XRT, HIGH, p < 0.05) (USMB+XRT vs. USMB+XRT, HIGH, p < 0.05) in contrast to wash-out DCE parameters that indicated an increase for the combination group (USMB+XRT vs. USMB+XRT, HIGH, p < 0.05). A decrease in area under the curve (AUC) was also observed for this group (USMB vs. USMB+XRT, HIGH, p < 0.05) (USMB+XRT vs. USMB+XRT, HIGH, p < 0.05). Furthermore, a modified Toft’s model indicated an increase in the ve parameter (not statistically significant) and a decrease in the vp and kep parameters in the combined group (Control vs. USMB+XRT, HIGH, p < 0.05) (USMB+XRT vs. USMB+XRT, HIGH, p < 0.05) and (USMB+XRT vs. USMB+XRT, HIGH, p < 0.05), respectively. Correlative histology was obtained and analyzed, indicating cellular destruction of the vasculature which was associated with imaging-based levels of response. Results from tumours that underwent further perfusion-targeted treatment (based on increased or decreased perfusion) indicated enhanced vascular responses (in hypo- or hypervascularized areas). Conclusion: DCE-MRI shows promise in monitoring treatment response.
Related
- P08.07.A Phase 2 trial of botensilimab (Fc-enhanced anti-CTLA-4), balstilimab (anti-PD-1) and doxorubicin delivered with ultrasound/microbubble-based blood-brain barrier opening in newly diagnosed MGMT unmethylated glioblastoma: initial report of feasibility, safety and immune correlatives
- Ultrasound-mediated cavitation of microbubble-infused dressings increases the therapeutic efficacy of piroxicam gel for hand arthritis: An intraindividual randomized controlled trial
- Left ventricular function and volumes from cardiac magnetic resonance and gated [13N]-ammonia positron emission tomography myocardial perfusion imaging in patients with ischemia with no obstructive coronary arteries: a prospective head-to-head comparison using hybrid positron emission tomography/magnetic resonance
- Quantitative analysis of tumor perfusion via contrast-enhanced ultrasound to predict the neoadjuvant chemotherapy efficacy for children with hepatoblastoma
- Where the Evidence Runs Out: Ten Open Questions in Myocardial Perfusion Scintigraphy and Stress Perfusion Cardiovascular Magnetic Resonance
BibTeX
@article{sharma2026dynamic,
title = {{Dynamic Contrast-Enhanced Magnetic Resonance Imaging (DCE-MRI)-Guided Perfusion-Targeted Ultrasound-Stimulated Microbubble Enhancement of Radiation Response in a Xenograft Tumour Model}},
author = {Deepa Sharma and Colleen Bailey and Evan McNabb and Wenyi Yang and Anoja Giles and Greg Stanisz and Gregory J. Czarnota},
journal = {Cancers},
year = {2026},
month = nov,
doi = {10.3390/cancers18233744},
url = {https://www.mdpi.com/2072-6694/18/23/3744},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - Dynamic Contrast-Enhanced Magnetic Resonance Imaging (DCE-MRI)-Guided Perfusion-Targeted Ultrasound-Stimulated Microbubble Enhancement of Radiation Response in a Xenograft Tumour Model
AU - Deepa Sharma
AU - Colleen Bailey
AU - Evan McNabb
AU - Wenyi Yang
AU - Anoja Giles
AU - Greg Stanisz
AU - Gregory J. Czarnota
PY - 2026
DA - 2026/11/23
JO - Cancers
DO - 10.3390/cancers18233744
UR - https://www.mdpi.com/2072-6694/18/23/3744
AB - Background: Ultrasound-stimulated microbubbles (USMB) have been demonstrated to enhance radiation-based tumour effects through synergistic action at the level of tumour vasculature. Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is a method that can be used for quantitative analysis of tissue vasculature. DCE-MRI parameters allow estimation of tissue perfusion and microvascular status. Methods: In the present study, DCE-MRI parameters were used to guide therapy modulation based on perfusion and were also used to monitor responses to treatment. New Zealand white rabbits bearing human-derived PC3 prostate cancer tumours were assigned to four different groups: untreated controls, animals treated with USMB (14 min; 750 kPa) alone, animals treated with 8 Gy dose of radiation therapy (XRT) alone, and animals treated with a combination of USMB+XRT. Animals receiving combined treatment were categorized in three groups: the first group received USMB+XRT, while the second and third groups received an additional 7 min pulse sequence in a particular area designated as lower perfusion (USMB+XRT, LOW) and high perfusion (USMB+XRT, HIGH), respectively. Treatment response was monitored using DCE-MRI, and changes in parameters were assessed before treatment (baseline) and at 24 h after treatment. Results: Results demonstrated that tumours treated with a combination of USMB and XRT exhibited a decrease in DCE-MRI-based measures of vascular characteristics (USMB+XRT vs. USMB+XRT, HIGH, p < 0.05). Wash-in (s-1) DCE parameters demonstrated a decrease for combined treatment (USMB vs. USMB+XRT, HIGH, p < 0.05) (USMB+XRT vs. USMB+XRT, HIGH, p < 0.05) in contrast to wash-out DCE parameters that indicated an increase for the combination group (USMB+XRT vs. USMB+XRT, HIGH, p < 0.05). A decrease in area under the curve (AUC) was also observed for this group (USMB vs. USMB+XRT, HIGH, p < 0.05) (USMB+XRT vs. USMB+XRT, HIGH, p < 0.05). Furthermore, a modified Toft’s model indicated an increase in the ve parameter (not statistically significant) and a decrease in the vp and kep parameters in the combined group (Control vs. USMB+XRT, HIGH, p < 0.05) (USMB+XRT vs. USMB+XRT, HIGH, p < 0.05) and (USMB+XRT vs. USMB+XRT, HIGH, p < 0.05), respectively. Correlative histology was obtained and analyzed, indicating cellular destruction of the vasculature which was associated with imaging-based levels of response. Results from tumours that underwent further perfusion-targeted treatment (based on increased or decreased perfusion) indicated enhanced vascular responses (in hypo- or hypervascularized areas). Conclusion: DCE-MRI shows promise in monitoring treatment response.
SN - 2072-6694
ER -