Ultrasound-mediated cavitation of microbubble-infused dressings increases the therapeutic efficacy of piroxicam gel for hand arthritis: An intraindividual randomized controlled trial
4 affiliations
- 1Graduate Institute of Biomedical Electronics and Bioinformatics, National Taiwan University, Taipei, Taiwan
- 2Division of Allergy, Immunology and Rheumatology, Department of Internal Medicine, Taichung Veterans General Hospital, Taichung, Taiwan
- 3Department of Post-Baccalaureate Medicine, College of Medicine, National Chung Hsing University, Taichung, Taiwan
- 4Graduate Institute of Biomedical Engineering, National Taiwan University of Science and Technology, Taipei, Taiwan
Abstract
Background: Combining ultrasound (US) with microbubbles (MBs) increases epidermal permeability and thus facilitates the transfer of drugs into deeper tissues.
Objectives: To investigate the efficacy of combining US-mediated MB cavitation with piroxicam gel for hand arthritis.
Design: A single-center, open-label, intraindividual randomized controlled trial.
Methods: Fifty-two adult patients (mean age 55.0 years; 76.9% females) with hand arthritis in at least three symptomatic joints participated in this study. Three affected joints in each patient were randomly assigned to one of three groups: MB/US group, US group, and control group. The MB/US group received US (1 MHz at 0.49 W/cm2 for 3 minutes) along with an MB-infused dressing immediately followed by piroxicam gel application (1%, 0.5–1 g) on days 1, 3, and 5; the US group received US along with pure gel application immediately followed by piroxicam gel application; and the control group received only piroxicam gel application. Assessments were performed before and after treatment using the pain visual analogue scale (VAS) score, the synovial hypertrophy (SH) area on B-mode images, and synovial vascularity in conventional and ultrafast power Doppler (PD) imaging. The therapeutic response was determined by the pain VAS score, B-mode imaging, and PD imaging.
Results: The pain VAS score was significantly lower in the MB/US and US groups than in the control group. The SH area improved in 78.8%, 59.6%, and 53.8% of cases in the MB/US, US, and control groups, respectively, while the synovial vascularity improved in 61.5%, 50.0%, and 51.9%, and the therapeutic response rates were 75.0%, 61.5%, and 53.8%, with MB/US showing a significant improvement over control (p = 0.024).
Conclusion: US-mediated cavitation of an MB-infused dressing enhances drug delivery and may improve the therapeutic response for hand arthritis, with no adverse events.
Related
- P08.07.A Phase 2 trial of botensilimab (Fc-enhanced anti-CTLA-4), balstilimab (anti-PD-1) and doxorubicin delivered with ultrasound/microbubble-based blood-brain barrier opening in newly diagnosed MGMT unmethylated glioblastoma: initial report of feasibility, safety and immune correlatives
- Dynamic Contrast-Enhanced Magnetic Resonance Imaging (DCE-MRI)-Guided Perfusion-Targeted Ultrasound-Stimulated Microbubble Enhancement of Radiation Response in a Xenograft Tumour Model
- Acoustic cavitation-mediated ultrasound-assisted extraction enhances recovery of antioxidant and antidiabetic phytochemicals from Tanacetum gracile: Stabilization through alginate–whey protein microencapsulation
- Prospective Intraindividual Split-face Histological Comparison of Poly-d,l-lactic Acid and Calcium Hydroxylapatite Skin Boosters Using Stem Cell Markers
- Therapeutic ultrasound for brain intervention: toward bioeffect-linked acoustic dose control
BibTeX
@article{lai2026ultrasoundmediated,
title = {{Ultrasound-mediated cavitation of microbubble-infused dressings increases the therapeutic efficacy of piroxicam gel for hand arthritis: An intraindividual randomized controlled trial}},
author = {Kuo-Lung Lai and Ai-Ho Liao and Pai-Chi Li},
journal = {Therapeutic Advances in Musculoskeletal Disease},
year = {2026},
month = sep,
doi = {10.1177/1759720x261493058},
url = {https://doi.org/10.1177/1759720x261493058},
note = {CC BY-NC 4.0},
}
RIS
TY - JOUR
TI - Ultrasound-mediated cavitation of microbubble-infused dressings increases the therapeutic efficacy of piroxicam gel for hand arthritis: An intraindividual randomized controlled trial
AU - Kuo-Lung Lai
AU - Ai-Ho Liao
AU - Pai-Chi Li
PY - 2026
DA - 2026/09/25
JO - Therapeutic Advances in Musculoskeletal Disease
DO - 10.1177/1759720x261493058
UR - https://doi.org/10.1177/1759720x261493058
AB - Background: Combining ultrasound (US) with microbubbles (MBs) increases epidermal permeability and thus facilitates the transfer of drugs into deeper tissues. Objectives: To investigate the efficacy of combining US-mediated MB cavitation with piroxicam gel for hand arthritis. Design: A single-center, open-label, intraindividual randomized controlled trial. Methods: Fifty-two adult patients (mean age 55.0 years; 76.9% females) with hand arthritis in at least three symptomatic joints participated in this study. Three affected joints in each patient were randomly assigned to one of three groups: MB/US group, US group, and control group. The MB/US group received US (1 MHz at 0.49 W/cm2 for 3 minutes) along with an MB-infused dressing immediately followed by piroxicam gel application (1%, 0.5–1 g) on days 1, 3, and 5; the US group received US along with pure gel application immediately followed by piroxicam gel application; and the control group received only piroxicam gel application. Assessments were performed before and after treatment using the pain visual analogue scale (VAS) score, the synovial hypertrophy (SH) area on B-mode images, and synovial vascularity in conventional and ultrafast power Doppler (PD) imaging. The therapeutic response was determined by the pain VAS score, B-mode imaging, and PD imaging. Results: The pain VAS score was significantly lower in the MB/US and US groups than in the control group. The SH area improved in 78.8%, 59.6%, and 53.8% of cases in the MB/US, US, and control groups, respectively, while the synovial vascularity improved in 61.5%, 50.0%, and 51.9%, and the therapeutic response rates were 75.0%, 61.5%, and 53.8%, with MB/US showing a significant improvement over control (p = 0.024). Conclusion: US-mediated cavitation of an MB-infused dressing enhances drug delivery and may improve the therapeutic response for hand arthritis, with no adverse events.
SN - 1759-720X
SN - 1759-7218
ER -