Skip to content
DraconiticResearch
Search Sources API
203,234 studies31 sourcesUpdated 10 min ago
Peer-reviewedCC BY 4.0Biotechnology Journal

Liquid‐Suspendable Metabolic Sensors Allow Real‐Time Oxygen Consumption Monitoring in Caco‐2 and Colon Organoid‐Based Gut‐on‐a‐Chip Models

5 affiliations
  1. 1Human and Animal Physiology Wageningen University Wageningen The Netherlands
  2. 2Mimetas B.V. Oegstgeest The Netherlands
  3. 3Cell Biology and Immunology Wageningen University Wageningen The Netherlands
  4. 4Division of Toxicology Wageningen University Wageningen The Netherlands
  5. 5Department of Food, Health and Consumer Research Wageningen Food & Biobased Research Wageningen The Netherlands

Abstract

The organ‐on‐a‐chip field is a rapidly evolving area of expertise, combining enhanced physiological relevance with a wide range of functional readouts across diverse cellular models. One such readout is oxygen metabolism, which serves as a key indicator of mitochondrial function. In this study, we utilized metabolic sensors designed for real‐time measurement of oxygen consumption, reflecting aerobic respiration, within a commercially available microfluidic platform. We demonstrated that time‐resolved detection of oxygen consumption is feasible within the system's microliter‐scale volumes and that chemically induced changes in cellular oxygen metabolism can be monitored in real time in two ready‐to‐use gut‐on‐a‐chip models. In summary, this novel application of metabolic sensors enables direct evaluation of mitochondrial function in complex cellular environments by addressing key analytical challenges often encountered in organ‐on‐a‐chip systems due to their limited size and structural complexity.

Related

  1. DNA nanodevice-engineered macrophages as living sensors for dual-mode in vivo monitoring of tumor-associated macrophage polarization
    Qiaomei Wei, Xixi Chen, Ping Xie +6
    Science AdvancesPeer-reviewedCC BY-NCMolecular biology & gene regulationCrossref
  2. Retinal organoid–based evaluation of icariin-loaded extracellular vesicles for hypoxia-induced retinal injury via mitochondrial modulation
    Mira Park, Hyeoun Ji Kim, Yoon-Ha Go +5
    Frontiers in cell and developmental biologyPeer-reviewedCC BYFull textGeneral biochemistryEurope PMC
  3. Single-cell multi-omic atlas and morphogen screening informs midbrain and hindbrain organoid engineering
    Nadezhda V. Azbukina, Zhisong He, Hsiu‐Chuan Lin +12
    Nature NeurosciencePeer-reviewedCC BY9 citedMolecular biology & gene regulationOpenAlex
  4. Automated spheroid and organoid image analysis from rule-based methods to deep learning
    Keith Ntokozo Ncube, Iman van den Bout, Werner Cordier
    SLAS DiscoveryPeer-reviewedCC BYFull textBiophysicsDOAJ
  5. Stop the swap: SNPTrace genotyping as routine authentication for human organoid biobank lines
    Xi-Lei Zeng, Jianhong Hu, Manveer Kaur +3
    BMC Research NotesPeer-reviewedCC BY-NC-ND 4.0Full textMolecular biology & gene regulationPMC
BibTeX
@article{devriese2026liquidsuspendable,
  title = {{Liquid‐Suspendable Metabolic Sensors Allow Real‐Time Oxygen Consumption Monitoring in Caco‐2 and Colon Organoid‐Based Gut‐on‐a‐Chip Models}},
  author = {Sarah Devriese and Flavio Bonanini and Anna F. Bekebrede and Sara Shafiei and Dorota Kurek and Coen Govers and Hans Bouwmeester and A. Paul Vos and Remko van Vught and Jaap Keijer and Vincent C. J. de Boer},
  journal = {Biotechnology Journal},
  year = {2026},
  month = nov,
  doi = {10.1002/biot.70333},
  url = {https://doi.org/10.1002/biot.70333},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Liquid‐Suspendable Metabolic Sensors Allow Real‐Time Oxygen Consumption Monitoring in Caco‐2 and Colon Organoid‐Based Gut‐on‐a‐Chip Models
AU  - Sarah Devriese
AU  - Flavio Bonanini
AU  - Anna F. Bekebrede
AU  - Sara Shafiei
AU  - Dorota Kurek
AU  - Coen Govers
AU  - Hans Bouwmeester
AU  - A. Paul Vos
AU  - Remko van Vught
AU  - Jaap Keijer
AU  - Vincent C. J. de Boer
PY  - 2026
DA  - 2026/11/04
JO  - Biotechnology Journal
DO  - 10.1002/biot.70333
UR  - https://doi.org/10.1002/biot.70333
AB  - The organ‐on‐a‐chip field is a rapidly evolving area of expertise, combining enhanced physiological relevance with a wide range of functional readouts across diverse cellular models. One such readout is oxygen metabolism, which serves as a key indicator of mitochondrial function. In this study, we utilized metabolic sensors designed for real‐time measurement of oxygen consumption, reflecting aerobic respiration, within a commercially available microfluidic platform. We demonstrated that time‐resolved detection of oxygen consumption is feasible within the system's microliter‐scale volumes and that chemically induced changes in cellular oxygen metabolism can be monitored in real time in two ready‐to‐use gut‐on‐a‐chip models. In summary, this novel application of metabolic sensors enables direct evaluation of mitochondrial function in complex cellular environments by addressing key analytical challenges often encountered in organ‐on‐a‐chip systems due to their limited size and structural complexity.
SN  - 1860-6768
SN  - 1860-7314
ER  -