Skip to content
DraconiticResearch
Search Sources API
194,161 studies31 sourcesUpdated 10 min ago
PreprintarXiv licencearXiv

Small-study effects on the hierarchical summary ROC curve: latent accuracy and threshold trends in meta-analysis of diagnostic test accuracy

Abstract

Diagnostic meta-analyses commonly assess small-study effects using the Deeks test, which tests for a study-size trend in the log diagnostic odds ratio. Under the hierarchical summary receiver operating characteristic (HSROC) model, this quantity reflects both latent accuracy and threshold unless the curve is symmetric. A threshold trend can therefore generate a log diagnostic odds ratio trend without a latent accuracy trend, or conceal an existing one. We develop a likelihood-ratio test of the latent accuracy trend under a common-shape binomial HSROC model. Its null hypothesis states that the summary curve is unchanged across study sizes. A log diagnostic odds ratio test using the same binomial fit provides a comparison with a different null hypothesis. In simulations, the proposed test remained near its nominal level under its null and had higher power than Deeks with a latent accuracy trend alone. In a colorectal cancer review of faecal immunochemical tests, it detected a negative latent accuracy trend obscured on the log diagnostic odds ratio scale by an opposing threshold contribution. All three tests detected size trends for impedance plethysmography in deep-vein thrombosis, where the fitted curve was nearly symmetric. The proposed test distinguishes changes in the summary curve from changes in operating position.

Related

  1. HiLNO: A Hierarchical Latent Neural Operator with Multi-Scale Supervision for PDEs on General Geometries
    Zhicheng Hu, Jiacheng Li, Min Yang
    arXivPreprintarXiv licenceFull textNumerical analysis & scientific computingarXiv
  2. The Geometry of Hierarchical Navigation: Accuracy and Query Cost for Point Process Input
    Shankar Bhamidi, Souvik Dhara, Lars Schroeder +1
    arXivPreprintarXiv licenceFull textProbabilityarXiv
  3. Hierarchical Bayesian Joint Modeling of Athlete Performance Trajectories and Latent Peak Ages
    K. Ken Peng, Tianyu Guan, Xiong Zhao
    arXivPreprintarXiv licenceFull textStatisticsarXiv
  4. Structural equation modelling--based meta-analytic model for diagnostic test accuracy studies
    Zelalem F. Negeri
    arXivPreprintarXiv licenceFull textStatisticsarXiv
  5. Robust bootstrap methods for meta-analyses of diagnostic test accuracy studies
    Diribsa T. Bedada, Olana A. Dabi, Isaac Fordjour +1
    arXivPreprintarXiv licenceFull textStatisticsarXiv
BibTeX
@misc{nonomiya2026smallstudy,
  title = {{Small-study effects on the hierarchical summary ROC curve: latent accuracy and threshold trends in meta-analysis of diagnostic test accuracy}},
  author = {Yuta Nonomiya and Kazuki Nishida},
  howpublished = {arXiv},
  year = {2026},
  month = oct,
  doi = {10.48550/arxiv.2609.38297},
  eprint = {2609.38297},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2609.38297},
}
RIS
TY  - UNPB
TI  - Small-study effects on the hierarchical summary ROC curve: latent accuracy and threshold trends in meta-analysis of diagnostic test accuracy
AU  - Yuta Nonomiya
AU  - Kazuki Nishida
PY  - 2026
DA  - 2026/10/17
PB  - arXiv
DO  - 10.48550/arxiv.2609.38297
UR  - https://arxiv.org/abs/2609.38297
AB  - Diagnostic meta-analyses commonly assess small-study effects using the Deeks test, which tests for a study-size trend in the log diagnostic odds ratio. Under the hierarchical summary receiver operating characteristic (HSROC) model, this quantity reflects both latent accuracy and threshold unless the curve is symmetric. A threshold trend can therefore generate a log diagnostic odds ratio trend without a latent accuracy trend, or conceal an existing one. We develop a likelihood-ratio test of the latent accuracy trend under a common-shape binomial HSROC model. Its null hypothesis states that the summary curve is unchanged across study sizes. A log diagnostic odds ratio test using the same binomial fit provides a comparison with a different null hypothesis. In simulations, the proposed test remained near its nominal level under its null and had higher power than Deeks with a latent accuracy trend alone. In a colorectal cancer review of faecal immunochemical tests, it detected a negative latent accuracy trend obscured on the log diagnostic odds ratio scale by an opposing threshold contribution. All three tests detected size trends for impedance plethysmography in deep-vein thrombosis, where the fitted curve was nearly symmetric. The proposed test distinguishes changes in the summary curve from changes in operating position.
ER  -