Skip to content
DraconiticResearch
Search Sources API
203,203 studies31 sourcesUpdated 35 min ago
Peer-reviewedCC BY 4.0Medical Physics

Influence of forehead gap size on eye protection provided by lead eyewear worn over prescription glasses: A Monte Carlo study

  1. 1Department of Radiological Technology Tohoku University Graduate School of Medicine Sendai Japan
  2. 2Division of Radiological Disasters and Medical Science Department of Disaster Medicine International Research Institute of Disaster Science Tohoku University Sendai Japan

Abstract

Background: Due to exposure to high levels of scattered ionizing radiation, interventional radiology (IR) physicians have an elevated risk of radiation‐induced eye injuries and cataracts. Previous studies have evaluated the protective effects of regular lead glasses and recommended measures to improve radiation protection for the eyes. However, the protective effects of fit‐over eyewear—lead eyewear worn over prescription glasses—have not been thoroughly examined. Importantly, a previous study noted that the space required to accommodate prescription glasses may reduce eye protection.

Purpose: Monte Carlo (MC) simulations were performed to quantify the protective effects of fit‐over eyewear and assess the relative effectiveness of adding bottom shields to conventional lead eyewear to improve eye protection.

Methods: Conventional lead glasses comprising front and side lenses and prescription glasses with plastic lenses and titanium frames were modeled. Lead glasses with bottom shields were created by bending the lower edges of the front lenses of conventional eyewear without increasing the total lens area. Three lead lens thickness values were tested: 0.07, 0.5, and 0.75 mm. Using a mesh‐type reference computational phantom representing an adult male to simulate an IR physician, MC simulations were performed with a transcatheter arterial chemoembolization setup. The Particle and Heavy Ion Transport code system was used to calculate the radiation dose deposited in each eye‐sensitive volume. The distance (d) between the forehead and front lead lens varied systematically. Protective effects were evaluated using the shielding rate (%) calculated as: (1‐Dpr /D 0) × 100, where D 0 is the radiation dose without protection and Dpr is the dose with eye protection.

Results: For the eye near the X‐ray source (left eye), the conventional models showed shielding rates >50% when the lead thickness was 0.5 or 0.75 mm and d was ≤0.5 cm. The conventional 0.07‐mm lead eyewear exhibited shielding rates <50% when d was 0.5 cm, and <26% when d was ≥0.8 cm. However, 0.07‐mm lead eyewear with bottom shields maintained approximately 50% shielding when d increased to 1.0 cm. The models using 0.5‐ or 0.75‐mm lead lenses with bottom shields exhibited shielding rates >76% at d = 1.0 cm. Notably, the shielding rates for the right eye were <12% regardless of introducing bottom shields. The right eye doses were 45–48% of the left eye lens dose without protection.

Conclusion: By quantifying the relationship between the size of the lens gap and shielding rates, this study estimates the protective effects of fit‐over eyewear and can help IR physicians select suitable eyewear. Our findings show that fit‐over eyewear with bottom shields effectively protects the left eye during posterior‐anterior projection. Although introducing bottom shields can improve conventional side‐shield models in terms of increased shielding rate for the left eye, the shielding rates for the right eye remained low because of the gap around the nose. Further study of new designs with a shielded covering over the nose may be warranted.

Related

  1. Diffuse Large B-Cell Lymphoma Presenting as a Rapidly Enlarging Forehead Mass Initially Suggestive of a Subgaleal Hematoma: A Case Report.
    Akitomo Yonenaga, Nobuo Isono, Ami Higashiyama +2
    Clinical case reportsPeer-reviewedCC BY-NCFull textGeneral medicineEurope PMC
  2. Muse 2 forehead photoplethysmography agrees with Polar H10 for heart rate but overestimates ultra-short RMSSD
    I. P. A. Griadhi, I. A. A. Suadnyana, N. Wahyuni
    medRxivPreprintCC BYFull textGeneral medicinemedRxiv
  3. Red forehead dot syndrome: a case report and review of literature
    Walid Alesefir
    Frontiers in pain research (Lausanne, Switzerland)Peer-reviewedCC BYFull textPsychiatry & mental healthEurope PMCPMC
  4. Factors affecting adolescent participation in HIV/AIDS prevention services provided by Non-Governmental Organizations in Iran
    Laleh Ghadirian, Azadeh Sayarifard, Haniye Sadat Sajadi +5
    BMC Public HealthPeer-reviewedCC BY-NC-ND 4.0Epidemiology & public healthCrossref
  5. The Effect of Prenatal Education and Home Telecare Provided According to Watson Care Model on Spouses’ Readiness for Childbirth, Fear of Childbirth, and Maternal and Paternal Attachment: A Case Report
    Tuğba Öz, Nurdan Demirci
    The Journal of Perinatal EducationPeer-reviewedLicence not statedFull textObstetrics, gynaecology & paediatricsPMC
BibTeX
@article{shindo2026influence,
  title = {{Influence of forehead gap size on eye protection provided by lead eyewear worn over prescription glasses: A Monte Carlo study}},
  author = {Ryota Shindo and Masaki Fujisawa and Keisuke Yamamoto and Kodai Sagehashi and Yohei Inaba and Koichi Chida},
  journal = {Medical Physics},
  year = {2026},
  month = oct,
  doi = {10.1002/mp.70734},
  url = {https://doi.org/10.1002/mp.70734},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Influence of forehead gap size on eye protection provided by lead eyewear worn over prescription glasses: A Monte Carlo study
AU  - Ryota Shindo
AU  - Masaki Fujisawa
AU  - Keisuke Yamamoto
AU  - Kodai Sagehashi
AU  - Yohei Inaba
AU  - Koichi Chida
PY  - 2026
DA  - 2026/10/25
JO  - Medical Physics
DO  - 10.1002/mp.70734
UR  - https://doi.org/10.1002/mp.70734
AB  - Background: Due to exposure to high levels of scattered ionizing radiation, interventional radiology (IR) physicians have an elevated risk of radiation‐induced eye injuries and cataracts. Previous studies have evaluated the protective effects of regular lead glasses and recommended measures to improve radiation protection for the eyes. However, the protective effects of fit‐over eyewear—lead eyewear worn over prescription glasses—have not been thoroughly examined. Importantly, a previous study noted that the space required to accommodate prescription glasses may reduce eye protection.  Purpose: Monte Carlo (MC) simulations were performed to quantify the protective effects of fit‐over eyewear and assess the relative effectiveness of adding bottom shields to conventional lead eyewear to improve eye protection.  Methods: Conventional lead glasses comprising front and side lenses and prescription glasses with plastic lenses and titanium frames were modeled. Lead glasses with bottom shields were created by bending the lower edges of the front lenses of conventional eyewear without increasing the total lens area. Three lead lens thickness values were tested: 0.07, 0.5, and 0.75 mm. Using a mesh‐type reference computational phantom representing an adult male to simulate an IR physician, MC simulations were performed with a transcatheter arterial chemoembolization setup. The Particle and Heavy Ion Transport code system was used to calculate the radiation dose deposited in each eye‐sensitive volume. The distance (d) between the forehead and front lead lens varied systematically. Protective effects were evaluated using the shielding rate (%) calculated as: (1‐Dpr /D 0) × 100, where D 0 is the radiation dose without protection and Dpr is the dose with eye protection.  Results: For the eye near the X‐ray source (left eye), the conventional models showed shielding rates >50% when the lead thickness was 0.5 or 0.75 mm and d was ≤0.5 cm. The conventional 0.07‐mm lead eyewear exhibited shielding rates <50% when d was 0.5 cm, and <26% when d was ≥0.8 cm. However, 0.07‐mm lead eyewear with bottom shields maintained approximately 50% shielding when d increased to 1.0 cm. The models using 0.5‐ or 0.75‐mm lead lenses with bottom shields exhibited shielding rates >76% at d = 1.0 cm. Notably, the shielding rates for the right eye were <12% regardless of introducing bottom shields. The right eye doses were 45–48% of the left eye lens dose without protection.  Conclusion: By quantifying the relationship between the size of the lens gap and shielding rates, this study estimates the protective effects of fit‐over eyewear and can help IR physicians select suitable eyewear. Our findings show that fit‐over eyewear with bottom shields effectively protects the left eye during posterior‐anterior projection. Although introducing bottom shields can improve conventional side‐shield models in terms of increased shielding rate for the left eye, the shielding rates for the right eye remained low because of the gap around the nose. Further study of new designs with a shielded covering over the nose may be warranted.
SN  - 0094-2405
SN  - 2473-4209
ER  -