Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 35 min ago
Peer-reviewedCC BY-NC 4.0Neurology and Therapy

Cerebrospinal Fluid Biomarker Ratio Concordance with Amyloid Positron-Emission Tomography: A Diagnostic Test Accuracy Meta-analysis

5 affiliations
  1. 1Center for Research and Memory Clinic, CITA-Alzheimer Foundation, Paseo Mikeletegi, 71, 20009 Donostia-San Sebastián, Gipuzkoa Spain
  2. 2Institute of Clinical Medicine-Neurology, University of Eastern Finland, Yliopistonrinne 3, 70211 Kuopio, Finland
  3. 3Neuro Center-Neurology, Kuopio University Hospital, Puijonlaaksontie 2, 70200 Kuopio, Finland
  4. 4Springer Health+, Springer, 22 rue de Palestro, 75002 Paris, France
  5. 5Global Medical Affairs, Roche Diagnostics International Ltd, Rotkreuz, Switzerland

Abstract

Introduction: Cerebrospinal fluid (CSF) biomarker ratios (amyloid-β [Aβ]42/Aβ40, phosphorylated-tau [pTau]/Aβ42, and total tau [tTau]/Aβ42) are lower-cost alternatives to amyloid positron-emission tomography (PET) for Alzheimer’s disease diagnosis. Among these CSF biomarker ratios, it is not clear whether concordance with amyloid PET is highest with Aβ42/Aβ40, pTau/Aβ42, or tTau/Aβ42. To evaluate this, we conducted a diagnostic test accuracy meta-analysis.

Methods: Medline and Embase were searched for articles published between January 2008 and February 2026 reporting concordance of ≥ 1 CSF biomarker ratio with amyloid PET. Statistical analyses were performed using the bivariate model of Reitsma with the R package mada v0.5.11.

Results: This quantitative meta-analysis comprised 38 studies, including a total of 7504 participants, with 35 studies available for statistical analysis. All three CSF biomarker ratios (Aβ42/Aβ40, pTau/Aβ42, and tTau/Aβ42) were highly concordant with amyloid PET. However, the pTau/Aβ42 ratio showed numerically higher overall percent agreement with amyloid PET positivity (90.4%) versus Aβ42/Aβ40 (89.5%) or tTau/Aβ42 (89.2%), a significantly higher area under the curve (0.955) versus Aβ42/Aβ40 (0.921, p value for difference 0.018), and a significantly lower false positive rate (0.116) versus Aβ42/Aβ40 (0.153, p value for difference 0.015).

Conclusion: pTau/Aβ42 showed the highest overall concordance with amyloid PET positivity and the lowest false positive rate versus Aβ42/Aβ40 or tTau/Aβ42.

Related

  1. Translocator protein positron emission tomography as a biomarker for posttraumatic epilepsy and behavioral comorbidities following traumatic brain injury
    Mohit Javalgekar, Peravina Thergarajan, Juliana Silva +12
    EpilepsiaPeer-reviewedCC BY 4.0Full text1 citedNeurologyPMC
  2. Diagnostic Accuracy of Computed Tomography for Radiographically Occult Scaphoid Fractures and Concordance With Magnetic Resonance Imaging: A Systematic Review.
    Rohin Wong, Andrien Rajakumar, Arkar Lwin +3
    CureusPeer-reviewedCC BYFull textSurgery & anaesthesiaEurope PMC
  3. Left ventricular function and volumes from cardiac magnetic resonance and gated [13N]-ammonia positron emission tomography myocardial perfusion imaging in patients with ischemia with no obstructive coronary arteries: a prospective head-to-head comparison using hybrid positron emission tomography/magnetic resonance
    Runze Wen, Qiang Xie, Ming Ni +5
    Quantitative imaging in medicine and surgeryPeer-reviewedCC BY-NC-NDFull textMedical imaging & radiologyEurope PMC
  4. Gallium-68 (68Ga)-Labelled Prostate-Specific Membrane Antigen Positron Emission Tomography/Computed Tomography in the Initial Staging of High-Risk Prostatic Adenocarcinoma: Reclassification to Oligometastatic Disease and Change in Treatment Intent
    Carlos Paul Villalba-Meneses, Adriana P Noboa, Veronica Marcela Villegas-Paredes
    CureusPeer-reviewedCC BYFull textGeneral medicineEurope PMC
  5. Combined Transcranial Sonography of the Substantia Nigra and 18F‐Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography in the Diagnosis of Parkinson's Disease and Atypical Parkinsonian Syndromes
    Tong Wu, Ziwei Zhou, Wenjie Gong +5
    Movement Disorders Clinical PracticePeer-reviewedLicence not statedFull textNeurologyPMC
BibTeX
@article{martinezlage2026cerebrospinal,
  title = {{Cerebrospinal Fluid Biomarker Ratio Concordance with Amyloid Positron-Emission Tomography: A Diagnostic Test Accuracy Meta-analysis}},
  author = {Pablo Martinez-Lage and Eino Solje and Julian G. Martins and Martin Guess and Sraboni Sarkar},
  journal = {Neurology and Therapy},
  year = {2026},
  month = oct,
  doi = {10.1007/s40120-026-01056-1},
  url = {https://doi.org/10.1007/s40120-026-01056-1},
  note = {CC BY-NC 4.0},
}
RIS
TY  - JOUR
TI  - Cerebrospinal Fluid Biomarker Ratio Concordance with Amyloid Positron-Emission Tomography: A Diagnostic Test Accuracy Meta-analysis
AU  - Pablo Martinez-Lage
AU  - Eino Solje
AU  - Julian G. Martins
AU  - Martin Guess
AU  - Sraboni Sarkar
PY  - 2026
DA  - 2026/10/22
JO  - Neurology and Therapy
DO  - 10.1007/s40120-026-01056-1
UR  - https://doi.org/10.1007/s40120-026-01056-1
AB  - Introduction: Cerebrospinal fluid (CSF) biomarker ratios (amyloid-β [Aβ]42/Aβ40, phosphorylated-tau [pTau]/Aβ42, and total tau [tTau]/Aβ42) are lower-cost alternatives to amyloid positron-emission tomography (PET) for Alzheimer’s disease diagnosis. Among these CSF biomarker ratios, it is not clear whether concordance with amyloid PET is highest with Aβ42/Aβ40, pTau/Aβ42, or tTau/Aβ42. To evaluate this, we conducted a diagnostic test accuracy meta-analysis.  Methods: Medline and Embase were searched for articles published between January 2008 and February 2026 reporting concordance of ≥ 1 CSF biomarker ratio with amyloid PET. Statistical analyses were performed using the bivariate model of Reitsma with the R package mada v0.5.11.  Results: This quantitative meta-analysis comprised 38 studies, including a total of 7504 participants, with 35 studies available for statistical analysis. All three CSF biomarker ratios (Aβ42/Aβ40, pTau/Aβ42, and tTau/Aβ42) were highly concordant with amyloid PET. However, the pTau/Aβ42 ratio showed numerically higher overall percent agreement with amyloid PET positivity (90.4%) versus Aβ42/Aβ40 (89.5%) or tTau/Aβ42 (89.2%), a significantly higher area under the curve (0.955) versus Aβ42/Aβ40 (0.921, p value for difference 0.018), and a significantly lower false positive rate (0.116) versus Aβ42/Aβ40 (0.153, p value for difference 0.015).  Conclusion: pTau/Aβ42 showed the highest overall concordance with amyloid PET positivity and the lowest false positive rate versus Aβ42/Aβ40 or tTau/Aβ42.
SN  - 2193-8253
SN  - 2193-6536
ER  -